Touch top unit

The blind/shutter moves in the lower end position direction.

Touch and hold surfaces (1) and (3) simultaneously.
The status indication (5) flashes once and then lights.

The blind/shutter stops and continues to move again after 4 seconds.

As soon as the blind/shutter has reached the lower end position, release the surfaces and
touch surface (3) within the next 4 seconds.
The status indication (5) flashes once.

The running time is saved. The blind/shutter moves back to the upper end position.

Blind/shutter position movements

The blind/shutter position can be set in two different ways with surface (4):

Swipe slowly over surface (4) and release at the desired position. The touch must be
longer than 1 second from the start of the touch to the release.
The status indication (5) follows the touch. Blind/shutter moves to the selected position
after the release.

Touch surface (4) at the desired position for longer than 1 second.
Blind/shutter moves to the selected position after the release.

Adjusting the slats

Touch surfaces (1) or (3) for less than 1 second.

Saving the slat change-over time

From the upper end position touch surface (3) for longer than 1 second.
The blind/shutter moves in the lower end position direction.

Touch and hold surfaces (1) and (3) simultaneously.
The status indication (5) flashes once and then lights.

The blind/shutter stops and continues to move again after 4 seconds.

As soon as the blind/shutter moves again, release the surfaces in any position and touch
and hold surface (1) within the next 4 seconds.
Slats open.

As soon as the slats are fully changed over, release surface (1).
The status indication (5) flashes once.

The slat change-over time is saved. The blind/shutter moves back to the upper end posi-
tion.

Saving the ventilation position

With a Venetian blind the blind/shutter position and the slat position are saved.

Move blind/shutter to the desired position and with a Venetian blind also set the slat posi-
tion.

Touch and hold surface (2) for longer than 4 seconds.
The status indication (5) flashes once.

The blind/shutter initially moves in the direction of the old ventilation position. After
4 seconds the blind/shutter stops, moves to the new ventilation position and saves it.

Release surface (4).

If the ventilation position is saved again, the old position is overwritten.

Activating / deactivating the disabling function

The disabling function disables extension operation in the "AB" direction. The local operation on
the top unit continues to be possible.

3 / 8

32403002

10867543

21.10.2020

Содержание System 3000

Страница 1: ...the device or load In so doing take all the circuit breakers into account which support dangerous voltages to the device and or load Danger of electric shock The device is not suitable for disconnect...

Страница 2: ...th Venetian blind insert Switching and dimming of lighting with insert for switching or dimming Three brightness values can be saved with insert for dimming Status indication through LED light bars to...

Страница 3: ...1 second The blind shutter moves in the lower end position direction Touch and hold surfaces 1 and 3 simultaneously The status indication 5 flashes once and then lights The blind shutter stops and con...

Страница 4: ...ghtness The brightness can be set in different ways Briefly touch surface 1 2 or 3 Light switches to the corresponding saved brightness values Swipe slowly over surface 4 and release at the desired br...

Страница 5: ...rightness value Adjust the brightness Press the button cover over entire surface for longer than 4 seconds The brightness value is saved as brightness value 1 For confirmation the light is switched of...

Страница 6: ...rts the load state changes with some actions Reset to default setting Switch off the mains voltage and switch on again Within the next 2 minutes simultaneously touch surfaces 1 and 3 for longer than 2...

Страница 7: ...time and also with Venetian blinds the slat adjusting time must be saved This happens on the main device see chapter Operation of Venetian blinds and shutters A fan position is also saved on the main...

Страница 8: ...bH Co KG Elektro Installations Systeme Industriegebiet Mermbach Dahlienstra e 42477 Radevormwald Postfach 12 20 42461 Radevormwald Deutschland Tel 49 0 21 95 602 0 Fax 49 0 21 95 602 191 www gira de i...

Отзывы: