Gira push-button/2-way low voltage Скачать руководство пользователя страница 5

Figure 4: Load curve of mixed loads 

Mixed-load operation of LED lamps or compact fluorescent lamps with other permissible 
loads possible. Note load curve (Figure 4). 

Power reduction 
when surface-mounted 

20 ... 450 W/VA 

per 5°C in excess of 25°C 

-10 % 

when installed in wooden or dry construction 
walls 

-15 % 

when installed in multiple combinations 

-20 % 

Connection 
single stranded 

1.0 ... 2.5 mm² 

Power boosters 

See power booster instructions 

Control output A 
Current carrying capacity 

100 mA 

The icons used to label the dimmer load show the load type that can be connected to 
a dimmer and the electric behaviour of a load: 
R = ohmic, L = inductive, HV LED = dimmable HV-LED lamps 

6.2 Troubleshooting 

Connected lamps switch off in the lowest dimming position or flicker 

Cause: The set minimum brightness is too low. 

Increase minimum brightness. 

Connected lamps flicker 

Cause: Lamps are not dimmable. 

Check manufacturer's instructions. 
Exchange lamps for another type. 

Connected lamps do not switch on in the lowest dimming position or only after a delay 

Cause: The set minimum brightness is too low. 

Increase minimum brightness. 

Connected lamps in the lowest dimming position are too bright; dimming range is too 
small 

Cause 1: The set minimum brightness is too high. 

Reduce minimum brightness. 

32534532 

10499194  I00 

20.12.2013 

5/6 

Dimmer push-button/2-way low voltage 

Отзывы: