5.2 Commissioning
Setting the minimum brightness
The minimum brightness can be set by an electrically skilled person as required.
DANGER!
Electrical shock when live parts are touched.
Electrical shocks can be fatal.
Use only insulated tools to set the minimum brightness! Cover up live parts in
the working environment.
The device is connected as described above and fitted in an appliance box. The frame, central
plate and control button are not fitted.
o
Switch on mains voltage.
o
Press the rotary axle to switch on the lighting and turn it left to the minimum brightness.
o
Adjust minimum brightness by turning the adjuster (8) (Figure 1).
i
According to EN 60669-2-1 (01.2000), lamp brightness should be detectable over the
whole load area, with darkness at – 10 % rated voltage.
o
Switch off the mains voltage.
o
Mount the frame and the central plate. Attach the control button.
o
Switch on mains voltage again.
6 Appendix
6.1 Technical data
Rated voltage
AC 230 / 240 V ~
Mains frequency
50 Hz
Ambient temperature
+5 ... +25 °C
Fine-wire fuse
D 3.15 H 250
Connected load at 25 °C
i
Power specifications including transformer power dissipation.
Incandescent lamps
20 ... 500 W
HV halogen lamps
20 ... 500 W
HV-LED lamps
typical 3 ... 100 W
Compact fl lamp.
typical 3 ... 100 W
Inductive transformers
20 ... 500 VA
i
Operate inductive transformers with at least 85% nominal load.
32534532
10499194 I00
20.12.2013
4/6
Dimmer push-button/2-way low voltage