16
Motion detector Cube
Safety information
Failure to observe the instructions can
result in damage to the device, fire or
other dangers.
Danger of electric shock. Device is not
suitable for isolation.
Danger of electric shock. Isolate before
working on the device or load. Take all cir-
cuit breakers supplying dangerous voltage
to the device or load into account.
Do not press on the sensor window. This
may damage the device.
The device is not suitable for use in burglar
alarm technology or alarm technology.
These instructions are part of the product
and must remain with the end customer.
Intended use
- Automatically switches lighting on/off, de-
pending on thermal motion and ambient
brightness.
- Suitable for indoor and outdoor ceiling
mounting and wall installation.
Product properties
- Floor and rear field monitoring (only with
motion detector Cube 240).
- Continuous light (max. 2 h) can be activat-
ed with optional switch.
- Test mode for evaluation of the detection
range.
- Individual adaptation of the detection
range via the enclosed, cut-to-size cover-
ing panel.
- Delay time: 5 s to 15 minutes or short-term
operation 1 s adjustable on the motion de-
tector Cube.
A delay time of max. 60 minutes can be set
with the remote control PIR 3.
- Teach-in, save current twilight value.
- Glare protection, brightness independent
sensor evaluation for 60 s in the event of
glare caused by extraneous light.
- Short-time operation, output is switched
on for approx. 1 s.
- Optional: Remote control via IR remote
control PIR 3.
Automatic mode
The motion detector detects thermal move-
ments of persons, animals or objects.
- The light is switched on if the detection
range is entered and the set brightness
threshold is not reached.
- The delay time is re-started with every mo-
tion detected.
- The light is switched off when no motion is
detected any more in the detection range
and the delay time expires or the ambient
light is sufficiently bright.
Response to a power failure
- Shorter than 0.2 s: Once the power supply
is restored, the old switching position is re-
established.
- Longer than 0.2 s: When the power supply
is restored, the motion detector is in test
mode for approx. 30 seconds.
Electrical devices may only be
installed and connected by a qual-
ified electrician.
EN
I
Note
- Test operation is only possible
with the optional IR remote con-
trol PIR 3.
- An optional cover with cable entry
for Cube motion detectors is avail-
able for connecting a surface-
mounted line.