background image

Installation and start-up

19

06.2017/V 1.2

2.9 

DIP switch on the circuit board of the call module

The factory setting is:

All 4 switches are in the left position, all options are "OFF".

Figure 2.3: DIP switch in the call module

DIP switch in the call module

Symbol meanings

Buzzer off/buzzer on
Factory setting: off

       

For future application

834+

For future application

Term

For future application

834+

Term

Содержание 834 Plus

Страница 1: ...Gira radio emergency set 5914 Gira radio emergency set Installation start up operation...

Страница 2: ......

Страница 3: ...with one or several devices 14 2 6 2 Deleting device assignment to a radio emergency set 15 2 6 3 Testing the connection quality of the installation 16 2 7 Relay in the radio call module 17 2 8 Start...

Страница 4: ...t of these documents may be duplicated or transmitted for any purpose regardless of the manner and means used electronic or mechanical without the expressed written consent of Gira Giersiepen GmbH Co...

Страница 5: ...rol electronics for the radio emergency set as well as the signal light and buzzer 1 Power supply 2 Relay connection 3 RS 834 connection 1 Programming button 2 Antenna 3 LED display 4 Battery 5 DIP sw...

Страница 6: ...Programming button 2 Antenna 3 LED display 4 Battery 5 Pull cord button Function Call triggering Triggers calls by pulling the cord Reassurance light in the housing Battery operated Device view Rear...

Страница 7: ...art order number 5930 Device view Power supply unit for flush mounted installation Function Power supply of the radio call module 230 V 12 V 1 A Power supply of the call module Can also be used for su...

Страница 8: ...proper use and or unprofessional installation of the emergency set 1 4 Functional description A call is triggered if a person in need of help pulls the cord of the radio pull cord button The triggered...

Страница 9: ...m in the free field 1 5 Interfaces and connection options The radio emergency set features the following interface The radio call module has a zero potential relay contact NC A Gira TeleCoppler Order...

Страница 10: ...Introduction 10 06 2017 V 1 2...

Страница 11: ...to the ground at least 0 5 m above the ground Basic rule the higher a radio component is installed the longer its range Attenuation of radio signals is achieved by reinforced concrete metal grids thic...

Страница 12: ...g up of the housing during operation is normal and safe Recommendation Position the power supply unit to partition the cables Recommendation Install the power supply unit and radio call module in deep...

Страница 13: ...ed or taught in 2 5 1 Removing the battery discharge protection Batteries are placed in the intended battery holder in the factory To avoid discharge during storage delivery a strip separates the batt...

Страница 14: ...ther For each device implement steps 2 to 3 in succession Step Set the device into programming mode Response signalling of the device during teach in 1 1 Device radio call module Press and hold the pr...

Страница 15: ...deleted Press and hold the program ming button for longer than 3 seconds 3 Result The device assignment to the set is deleted and the status LEDs on both devices flash rapidly The device deleted from...

Страница 16: ...the connection quality of several devices one after another For each device implement steps 1 and 2 in succession Step Set the device into test mode Visual and acoustic display of the connection qual...

Страница 17: ...asure the 12 V DC supply voltage of the power supply unit The power supply must not drop below 11 8 V DC Pull the cord of the radio pull cord button The red light in the housing of the radio pull cord...

Страница 18: ...ed signal light of the call module outside adjacent to the door of the WC The call is switched off with the switch off button in the WC area next to the door when the danger situation has been dealt w...

Страница 19: ...The factory setting is All 4 switches are in the left position all options are OFF Figure 2 3 DIP switch in the call module DIP switch in the call module Symbol meanings Buzzer off buzzer on Factory s...

Страница 20: ...ation e g unsuitable climatic conditions humidity e g unsuitable distance between the call module and the other devices Eliminating the cause e g select a suitable installation location e g create sui...

Страница 21: ...itable distance between the call module and the other devices Eliminating the cause e g select a suitable installation location e g create suitable climatic conditions low humidity e g ensure suitable...

Страница 22: ...ld for longer than 10 seconds 2 10 5 Device defect If all other fault sources have been excluded and a device is still unable to establish a radio connection then a device reset must be carried out wi...

Страница 23: ...l light of the radio call module 3 2 Call signalling Radio pull cord button The call is signalled with a lighting up of the reassurance light in the housing of the radio pull cord button Radio call mo...

Страница 24: ...batteries can be ordered with the Gira order number Battery type CR2 3 V 800 mAh for the radio call module order number 5988 00 Battery type 1 2 AA 3 6 V 1 200 mAh for pull cord button and switch off...

Страница 25: ...cord button 1 x 1 2 AA 3 6 V 1 200 mAh Radio switch off button Installation in installation box DIN 49073 Lithium battery in radio switch off button 1 x 1 2 AA 3 6 V 1 200 mAh Transmission frequency 8...

Страница 26: ...evices 5 Warranty The warranty is provided in accordance with statutory requirements via the specialist trade Please submit or send faulty devices postage paid together with an error description to yo...

Страница 27: ......

Страница 28: ...10231058 I02 06 17 Gira Giersiepen GmbH Co KG Electrical installation systems P O Box 12 20 42461 Radevormwald Germany Phone 49 0 2195 602 0 Fax 49 0 2195 602 191 www gira com info gira com...

Отзывы: