General safety instructions
Improper installation may result in serious
injury, e.g. from electrical shock or fire, as
well as equipment damage. Danger of
electric shock. Take account of all circuit
breakers supplying dangerous voltage to
the device or load. Comply with guidelines
and standards valid for SELV circuits for
installation and cable routing. Read these
instructions in full and observe them.
These instructions are part of the product
and must remain with the end customer.
Product features
The DCS IP data interface is an active
component for expanding a Gira door
communication system. The data interface
is used to expand the current push-button
commissioning procedure by adding
convenient commissioning via PC/laptop
and to connect the 2-wire bus to IP.
Properties
• Configuration via Gira Project Assistant
(GPA) from version 3.0.
• Commissioning of large projects.
• Reading out of the configuration data of
existing systems.
• Connection of Gira 2-wire bus to IP.
• Only suitable for indoor use.
Included in delivery
• 1 x DCS data interface
• 1 x operating instructions
• 2 x connection terminal
• 1 x cover for connection terminal
Ensure the package contents are complete
and undamaged. Please see “Warranty” in
case of any defects.
Electrical devices may only be
installed and connected by a
qualified electrician.
Device description
Installing the DCS IP data
interface
1. Switch the mains voltage off.
2. Place the device on the top-hat rail (TS-
35 acc. to DIN 60715). The network
connection must be located on the
bottom.
3. Connect the external power supply.
Recommendation: Use the white-yellow
connection terminal
4. Connect the Gira 2-wire bus.
Recommendation: Use the red-black
connection terminal.
5. Attach a cover cap to protect the bus
connection from dangerous voltages in
the connection area.
6. Establish the network connection.
1 Port: Additional power supply
2 Programming LED (red, reserved for future
use)
3 Function LED (green)
4 Mode/Progr.-LED (orange)
5 Port: Network (2x) incl. LEDs
6 Reserved for future use
7 Programming button
8 Port: Two-wire bus
DANGER
Touching live parts can result in serious
material damage or injuries, e.g. due to
fire or an electric shock.
Isolate before working on the device and
cover up live parts in the vicinity.
1
2
3
4
6
7
8
5
GPA
12V DC
2 A
IP
Data
Integrating the DCS IP data
interface into the Gira door
communication system
1.
Control device:
Press the "System
progr." button on the control device for 3
sec. and start the programming mode.
The LED on the control device flashes
orange.
2.
DCS IP data interface:
The LED Mode/
Progr. flashes orange.
3.
Control device:
Briefly press the
"System progr." button on the control
device and end the programming mode.
Commissioning via GPA
LEDs
Function LED (green)
Mode/Prog.-LED (orange)
Gira Project Assistant (GPA)
Configuring the DCS IP data interface via
the GPA (from version 3.0). The following
settings are made in the GPA:
• Assigning the bus address.
• Assigning call buttons and home
stations, etc.
• Begin Commissioning.
Download and install the GPA in the Gira
download area (www.gira.de/service/
download/gpa).
Quick Start Guide
In the GPA, download the Quick Start
Guide for starting up the device.
The Quick Start Guide is available at
www.gira.de/service/download or in the
online catalogue.
LED
Meaning
Off
IP module not working
Flashes 3 x
Bus voltage failure
Flashes slowly
Not configured
Steady green
Normal operation
LED
Meaning
Off
Normal operation
On
Boot loader bus coupler
active
Flashes (1 Hz)
Normal operation;
Systemprog. active on
control device
Flashes
cyclically (pause
2 s + 1 pulse in
0.5 s)
Tamper protection (error
bus address control
device)
Flashes
cyclically (pause
2 s + 2 pulse in
0.5 s)
IP module is starting up
Flashes
cyclically (pause
2 s + 3 pulse in
0.5 s)
Data interface is
transferring project data
Flashes
cyclically (pause
2 s + 4 pulse in
0.5 s)
Error during transfer of
project data
108
659
11
30/1
8
DCS IP data interface
5500 000