background image

General safety instructions

This product contains button cells. Swallow-
ing button cells may cause severe internal 
burns within two hours. This can be fatal.
Do not swallow batteries. Risk of burns 
from hazardous materials. Immediately 
seek medical attention if batteries have 
been swallowed or inserted into any part 
of the body.
Danger of acid burns from bursting or 
leaking batteries.
Keep new and used batteries away from chil-
dren.
These instructions are part of the product 
and must remain with the end customer.

Product features

The wireless hand-held transmitter can be 
used to set the security area to "Internally or 
Externally armed" or to disarm the area. In 
addition, irrespective of the status of the 
security area, the panic alarm can be 
manually triggered with the wireless hand-
held transmitter in an emergency (e. g. 
aggression).

Included in delivery

1 x wireless hand-held transmitter incl. 
      battery
1 x operating instructions
2 x stickers with Hardware ID

Ensure the package contents are complete 
and undamaged. Please see “Warranty” in 
case of any defects.

Observe the commissioning order

Commissioning order for the security 
system Alarm Connect:
1. Mount the alarm control unit and put it 

into commission (battery and 230 V 
connection).

2. Configure the project in the GPA and 

transfer it to the alarm control unit 
memory.

3. Install all other devices, put into 

commission (insert batteries, etc.) and 
check the wireless connection to the 
alarm control unit.

4. After successful verification, set the 

alarm control unit to operation mode.

Failure to observe the commissioning 
sequence will render commissioning of the 
safety system unsuccessful.

Required accessories

• Alarm control unit Connect 

(item no. 5201 00)

Device description

Commissioning the hand-held 
transmitter

After commissioning via GPA, each new 
wireless hand-held transmitter must be 
manually linked to the alarm control 
panel Connect.
1. Put the alarm control unit Connect in 

configuration mode (remove housing 
cover). The tamper alarm is triggered.

2. Briefly press the pairing button: The 

status LED will flash red and the pairing 
mode will be activated for 15 min. After 
15 min, the pairing mode will 
automatically end and the status LED 
will glow a steady green.

3. Within the 15 min, on the wireless hand-

held transmitter, press and hold the keys 

 

&  

for approx. 3 s. The LED status 

first flashes red and then briefly lights up 
green. The alarm control unit Connect 
has successfully transmitted its 
hardware ID to the wireless hand-held 
transmitter. The wireless hand-held 
transmitter is ready to operate.

Sticker with Hardware ID

The device comes with two stickers with 
the Hardware ID. You can use one of the 
two stickers for your site map and simply 
scan the Hardware ID with an appropriate 
scanner during configuration in GPA.

1

“Disarm”

2

“Externally arm”

3

“Internally arm”

4

For panic alarm only

5

Battery compartment, rear side 
(including cover and screw)

6

Status  LED

Conditions for device 
commissioning

The project must first be successfully 
commissioned in GPA (see 
"Commissioning order").

Gira Project Assistant (GPA)

The security system Alarm Connect is 
configured via GPA. The following settings 
are made in GPA for the wireless hand-held 
transmitter:
• Assign device ID.
• Enter  device  name.
• Put the project into commission.

6

2

4

1

3

5

4. Put the alarm control unit Connect into 

operating mode (housing cover closed) 
and confirm the tamper alarm on the 
wireless operating unit.

Operating the wireless hand-held 
transmitter

Activate "Externally armed"

Press the 

 button for approx. 3 s, then 

release. The status LED first flashes red and 
then green. Then the 

 button flashes red 

briefly: the security area is switched to 
"Externally armed".

Activate "Internally armed"

Hold down the 

 button (approx. 3 s). The 

status LED (1) first flashes red and then 
green. Then the 

 button flashes red 

briefly: the security area is switched to 
"Internally armed".

Disarm

Hold down the 

 button (approx. 3 s). The 

status LED first flashes red and then green. 
Then the 

 button flashes red briefly: the 

security area is switched to "disarmed".

Manually trigger panic alarm

Keep the 

 

 

&  

 buttons pressed 

(approx. 3 s). The status LED first flashes 
red and then green: the alarm is tripped, and 
all appropriately parametrised devices for-
ward the alarm signal.

The following message is shown in the 
display of the wireless operating unit:

Reset wireless hand-held transmitter

Hold down the 

 & 

 buttons 

(approx. 7 s) until the status LED flickers 
red/green.

The wireless hand-held transmitter is now 
reset and is now in the default delivery 
state.

Deactivate panic alarm

The panic alarm can only be deactivated at 
the wireless operating unit by entering the 
user PIN!

Ongoing panic alarm 
Deactivate alarm by
PIN entry 

1

086

392

4   4

3

/18

Wireless hand-held transmitter

5217 00

Operating instructions

en