General safety instructions

Improper installation may result in serious 
injury, e.g. from electrical shock or fire, as 
well as equipment damage.
This product contains a rechargeable bat

-

tery.
These instructions are part of the product 
and must remain with the end customer.

Product features

Included in delivery 

1 x GSM module 
1 x operating instructions

Ensure the package contents are complete 
and undamaged. Please see “Warranty” in 
case of any defects.

Required accessories

• Alarm control unit Connect

(item no. 5201 00)

Electrical devices may only be 
installed and connected by a 
qualified electrician.

SIM card

Observe the following:
• The SIM card (Mini SIM) is not included

in the delivery and must be purchased

separately.

• Using a SIM card may incur additional

mobile costs.

• For prepaid cards, ensure sufficient

credit or activate automatic recharging.

The credit balance is not displayed in the

system.

Inserting the GSM module

1. Alarm control unit Connect: remove the

housing cover (see operating
instructions „Alarm control unit
Connect“).

2. Remove the cover (see arrow) of the

GSM module slot.

3. Put the GSM module on the slot and

close the cover again.

4. Slide the lock of the SIM card holder in

direction „OPEN“ (to the right rechts)
and unfold upwards.

5. Insert the SIM card into the unfolded

part of the SIM card holder. Note the
insertion position of the SIM card! Do
not put the SIM card directly on the
contacts. If the SIM card is inserted
incorrectly, the SIM card holder can not
be closed.

6. Close the SIM card holder and slide the

lock back in the direction "LOCK" (to the
left).

Insert SIM card

When positioning the SIM card, make sure 
that the contact surface of the SIM card lies 
exactly on the contact pins of the GSM 
module, otherwise no mobile connection 
will be established.

AMT TEL

A2

B2

B

A

L

N

L

N

LAN

Which mobile phone tariff is needed?

Check the signal strength of the 
mobile connection at the 
installation site of the alarm 
control unit

Before the alarm control unit Connect is 
mounted and wired with a GSM module, it 
must be checked whether the selected 
installation site allows a mobile connection 
and the signal strength is sufficient.

1. Connect the alarm control unit Connect

to the rechargeable battery pack and the
mains voltage (see operating
instructions „Alarm control unit
Connect“).

2. Configure the alarm control unit Connect

in the GPA and activate the mobile
connection under [Alarm system]
-> [Basic settings] -> [Configure
connections]. It may be necessary to
enter a SIM PIN to activate the SIM card.

3. Commission the project.
4. The LED of the GSM module shows if a

mobile connnection is possible with the
SIM card.

 LED of the GSM module

5. After successful commissioning,

disconnect the mains voltage and the
Ethernet cable from the alarm control
unit Connect.

6. Hold the pairing button on the alarm

control unit Connect for approx. 10 s
until the status LED flashes. The status
LED indicates whether there is a mobile
connection and if the signal strength is
sufficient.

Status LED

* data connection for future use

GSM

GPRS (2G)

Voice Language service for future use
SMS

SMS sevice

for future use

Determine the signal strength at 

the installation site

The field or signal strength determined 
during the measurement is only a 
snapshot. 
Depending on the time of the day or the 
season as well as weather conditions, the 
quality of the signal strength may 
fluctuate.

Behaviour

Meaning

Blinks regularly 

no connection

Blinks with breaks

connected

Behaviour

Meaning

Flashes red and 
orange

Error GSM module

Lights up 
permanently orange

GSM module ok, 
but no signal 
available

Blinks 1 to 5 x orange 
with 2 s break (see 
following picture)

Mobile connection 
available, but data 
connection* not 
possible

Blinks 1 to 5 x green 
with 2 s break (see 
following picture)

Mobile and data 
connection 
available

10867741 

 14/20

GSM module

5204 00

Operating instructions

en