background image

6

Function range of the colour camera

The colour camera of the flush-mounted door station has the following product features:

Automatic day/night switching

The camera switches from daytime mode (colour presentation) to night mode (black and 
white presentation) and back again at an ambient brightness of 1 Lux. Due to the high 
degree of light sensitivity in night mode, good presentation results are achieved even with 
poor lighting conditions (to 0.1 Lux). In night mode, the integrated white LEDs ensure an 
even illumination of the field of view.

Large coverage range

The colour camera can be swivelled manually by 20º horizontally and vertically during 
start-up. A very large field of view in the door entry area results in conjunction with the 
100° range of coverage of the camera.

Camera heating

The integrated temperature-dependent camera heating prevents condensation from 

forming on the camera cover plate due to fluctuating climactic conditions and thus 

provides a clear view.

Camera cover plate

The splash water-resistant camera cover plate made of shock-resistant plastic can be 

easily replaced if damaged, for example by vandalism.

Setting coverage range of the colour camera

The CCD sensor element of the colour camera has an angle of detection of 100°. If this 
angle of detection is not sufficient for the required installation scenario, the area can be 
manually swivelled by 20° in all directions.

Coverage range of camera with 

perpendicular lens.

Coverage range of camera when lens is 

swivelled by 20°.

0,6 m

0,7 m

Haustür

Türstation

1,4 m

0,6 m

20°

Haustür

Türstation

Содержание 2551 20

Страница 1: ...Installation and Operating Instructions Door Station Stainless Steel Video 2551 20 2552 20 2553 20 2554 20 2556 20 2558 20 2559 20 2560 20 2562 20...

Страница 2: ......

Страница 3: ...colour camera 6 Selection of the installation site 7 Installing panel box 8 Installing front panel 10 Start up 11 Multi function input 11 Setting coverage range of the colour camera 12 Opening Door S...

Страница 4: ...4...

Страница 5: ...a fully secured and flameproof glass plate The inscription labels can be opened via a covered mechanism and can then removed from the front Both the call buttons and inscription labels are uniformly...

Страница 6: ...in the door entry area results in conjunction with the 100 range of coverage of the camera Camera heating The integrated temperature dependent camera heating prevents condensation from forming on the...

Страница 7: ...lumination of the field of view in dark ness If the entry area is equipped with additional illumination this light source must not shine directly into the camera lens from the front The best installat...

Страница 8: ...level With the later mounting of the Door Station Stainless Steel there is no possibility for correction The panel box must be installed as flush to the surface as possible It must be ensured that the...

Страница 9: ...9 4 Mount the included plaster protection 5 Plaster the wall 6 Carefully remove the plaster and take out the plas ter protection...

Страница 10: ...ation Stainless Steel into the mounting retainers 2 and attach the catch strap of the front panel to the hook of the locking plate 3 4 Connect the 2 wire bus to the BUS terminals i Insert locking plat...

Страница 11: ...input of the stainless steel door station s built in loudspeaker via the included connec tion cable The push button then has the same function as a call but ton and can therefore be used for example...

Страница 12: ...ra in the front panel and check on the TFT display of the con nected home station whether the set angle of the camera lens is adjusted properly and whether the view of the person in front of the door...

Страница 13: ...t double column door stations have two lower fastening bolts The position of the fastening bolts is shown via small recesses on the lower side of the front panel 2 Lift the front panel from the lower...

Страница 14: ...losed plastic key twist the plastic key anti clockwise until it engages 2 Engage the call button press the call button firmly inwards by c 1 cm The call button engages and stays in the pressed positio...

Страница 15: ...ghtly and turn it clockwise until the call button is released from the lower position 8 Lock the call button To do this turn the plastic key clockwise again until it engages 9 For function test press...

Страница 16: ...re four volume levels in total The next highest volume is set with each press of the button When the loudest volume level is reached the next press of the button sets the quietest volume level 5 Endin...

Страница 17: ...332 x 60 mm panel box 160 x 352 x 3 mm front panel 6 gang 8 gang 9 gang 140 x 417 x 60 mm panel box 160 x 437 x 3 mm front panel 10 gang 12 gang 250 x 265 x 60 mm panel box 270 x 285 x 3 mm front pan...

Страница 18: ...ements via the specialist trade Please submit or send faulty devices postage paid together with an error description to your responsible salesperson specialist trade installation company electrical sp...

Страница 19: ...19...

Страница 20: ...Gira Giersiepen GmbH Co KG Elektro Installations Systeme Postfach 1220 42461 Radevormwald Deutschland Tel 49 0 21 95 602 0 Fax 49 0 21 95 602 191 www gira de info gira de 10 41 09 25 20 11...

Отзывы: