Limiting the detection area 

Figure 4: Push-on cover 

The push-on cover can be used to limit the detection area, e.g. in order to mask out interference 
sources. 

Cover size 

Range on the ground (height 3 m) 

Complete push-on cover 

Ø approx. 4.5 m 

Area I cut out 

Ø approx. 7.5 m 

Areas I + II cut out 

Ø approx 12 m 

without push-on cover 

Ø approx. 20 m 

Pull off push-on cover. 

Using scissors, cut out push-on cover along the marked lines as required. 

Push on push-on cover. 

Aligning the device  

The device has three independent sensors for motion detection. The arrangement of the areas 
A, B and C is clearly evident under the decor ring (Figure 6). 

82585602 

20.09.2012 

6/10 

KNX/EIB 

Presence detector 

Содержание 2105 02

Страница 1: ...ow Device can be damaged The device is not suitable for use as a burglar alarm or other alarm Caution Damage to sensors may result due to high thermal radiation Avoid direct sunlight penetration in th...

Страница 2: ...tment of sensitivity Status LED Flashes during motion detection depending on programming in normal operation or only during the walking test mode Additional characteristics of Comfort version Manual o...

Страница 3: ...Function block 1 Brightness independent operation Function block 1 Set current brightness as brightness threshold Function block 1 Extend minimum run on time 10 seconds by the selected value Function...

Страница 4: ...seconds can be extended individually o Extend run on time Depending on requirement press button button button button or button Other values can be set with the buttons 5 Information for electrically s...

Страница 5: ...is installed on the ceiling and monitors the surface below it When used as a motion detector the device is installed e g in the hallway on the ceiling o Select a vibration free installation location V...

Страница 6: ...ea I cut out approx 7 5 m Areas I II cut out approx 12 m without push on cover approx 20 m o Pull off push on cover o Using scissors cut out push on cover along the marked lines as required o Push on...

Страница 7: ...n a flush mounted box Flush mounted appliance box is mounted on the ceiling at the designated installation location o Pull off decor ring 3 o When mounting the supporting frame 1 make sure that the ar...

Страница 8: ...connected The physical address and application software are loaded o Activate walking test Activate parameter walking test after download and download application software The presence detector opera...

Страница 9: ...hting Cause 1 The set time is too short Increase the time with the remote control or parameter setting Cause 2 Detection problem the surface to be monitored is not in the detection area or furniture o...

Страница 10: ...r No 2116 00 6 4 Warranty The warranty is provided in accordance with statutory requirements via the specialist trade Please submit or send faulty devices postage paid together with an error descripti...

Отзывы: