Страница 2: ...to 8 mechanical bell buttons can be con nected to the built in loudspeaker Addi tional bell buttons can be connected via add on modules It is possible to connect up to 5 add on modules with 12 bell b...

Страница 3: ...k 4 Interfaces System Connection for add on module or other system components Video Connection of the UP colour camera 5 Terminal strip BUS Connection to the 2 wire bus ZV Supply of UP colour camera e...

Страница 4: ...speech cover plate of the existing sys tem Depending on the design this is carried out directly on the front panel or via an installation carrier Attention Installation and mounting of electrical dev...

Страница 5: ...position of the microphone should be given a higher prior ity The best speech quality is achieved when a separating bar is located between the loud speaker and the microphone Connection 1 Connect the...

Страница 6: ...lots Do not connect 0 terminal When using an add on module the 0 ter minal of the built in loudspeaker may not be connected to the 0 terminal of the add on module i Illumination of bell buttons The il...

Страница 7: ...the colour camera with the built in speaker using the 2 pole video connection cable and the 6 pole audio connection cable 2 Fit jumpers between the BUS and ZV ter minals on the built in loudspeaker I...

Страница 8: ...ng is described in the system manual included with the control device i Note When commissioning large systems please note that a maximum of 20 bell but tons can be temporarily stored per work step If...

Страница 9: ...press a previously assigned bell button at the door station 3 The second person accepts the door call at the home station via receiver or speech button and starts speaking 4 Briefly press the bell but...

Страница 10: ...10 5 End the voice connection The most recently set volume level is saved in the door station 6 Exit programming mode at the control device by briefly pressing the System progr button...

Страница 11: ...eturn the unit postage paid to our central service department giving a brief description of the fault Gira Giersiepen GmbH Co KG Service Center Dahlienstra e 12 42477 Radevormwald Germany The CE sign...