2.0 Installation
2.4.5 Ventilation/Extraction
In compliance with the installation regulations, the ovens must be used in premises suitable for the evacuation of combustion products.
The oven must be installed under an extraction canopy that meets AS 1668.2. and in accordance with all local council regulations.
When the appliance is installed under the extraction hood, check that the following indications are respected:
• The volume extracted must be higher than that of the flue gases generated (see current regulation)
• The material with which the hood filter is made must resist the temperature of the flue gases which, on exiting the appliance, can reach
300°C
• The end part of the appliance flue pipe must be positioned inside the base perimeter projection of the hood
2.4.4 Gas Conversion
• Please ensure the unit is the correct gas type for the supplied gas. Gas type is nominated on the appliances rating plate
• Should the appliance require converting to an alternative gas type please contact Stoddart as this must be carried out by an Authorised
Service Technician