![Giorik KB061WT Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/giorik/kb061wt/kb061wt_specification-installation-and-operation-manual_2228798013.webp)
Page 12
Due to continuous product research and development,
the information contained herein is subject to change without notice.
www.stoddart.com.au
www.stoddart.co.nz
2.4 Gas Connection (Gas Models Only)
2.4.1 Connecting the gas
2.4.2 Rating Plate - Check Before Installation
WARNING
This unit must be installed by an authorised person in accordance with this instruction
manual, AS/NZS 5601 – Gas installations (installation and pipe sizing), local gas fitting
regulations, local electrical regulations, local water regulations, local health regula-
tions, Building Code of Australia and any other government authority.
The oven is calibrated originally for operation with the type of gas specified on placing the order. The type of gas for which the oven is adjusted
is given on the technical Installation prescriptions. The oven installation and commissioning operations must be performed by qualified staff
only in compliance with rules and regulations in force. The gas, electrical connections and the installation location of the oven must be in
compliance with the regulations and the standards in force.
Note that the air necessary for combustion of the burners is 2 m³/h per kW of power installed. This appliance is suitable for connection with
rigid pipe or flexible hose. The isolating manual shut-off valve connection point must be accessible when the appliance is installed.
Natural Gas:
the supplied regulator must be fitted to the appliance inlet connection. Gas pressure must be adjusted to 1.00 kPa when the
burner is operating at high flame, the appliance test point is located on the regulator.
Universal LPG:
the supplied regulator must be fitted to the appliance inlet connection. Gas pressure must be adjusted to 2.70 kPa when the
burner is operating at high flame, the appliance test point is located on the regulator.
Confirm that this unit has been tested and approved for the type of gas used
at the installation location.
Model Number
Main
Burner
Gas Type
Gas Orifice
(mm)
Aeration (mm)
Test Point
Pressure
(kPa)
Total NGC
(MJ/h)
Air/Gas
Ratio Adjustment
(Turn Clockwise to fully close)
KBG061WT
1
Natural
Gas
3.3
12.2
1.0
20.0
5 turns (From Closed)
KBG101WT
1
3.4
12.2
40.0
5 turns (From Closed)
KBG061WT
1
Universal
LPG
2.7
12.2
2.70
20.0
3 turns (From Closed)
KBG101WT
1
2.8
12.2
40.0
4 turns (From Closed)
Rating Plate example
Imported by:
STODDART
www.stoddart.com.au
Model No:
KBG061WT
Serial No:
004738/05/20
Description:
Giorik; Kore
; COMBI OVEN GAS
Gas Approval No. Gas Injector
3.3mm for Natural Gas
2.7mm for Universal LPG
Factory set gas type
Natural Gas
Universal LPG
Total gas consumption
20.0 MJ/h
Electric Rating
V 230
kW 1.5
Test Point Pressure
1.00 kPa Natural Gas
2.70 kPa Universal LPG
HZ 50
Ph 1
Imported by:
STODDART
www.stoddart.com.au
Model No:
KBG101WT
Serial No:
005925/06/20
Description:
Giorik; Kore
; COMBI OVEN GAS
Gas Approval No. Gas Injector
3.4mm for Natural Gas
2.8mm for Universal LPG
Factory set gas type
Natural Gas
Universal LPG
Total gas consumption
40.0 MJ/h
Electric Rating
V 230
kW 1.5
Test Point Pressure
1.00 kPa Natural Gas
2.70 kPa Universal LPG
HZ 50
Ph 1
2.0 Installation
Must use restraining cable if oven is installed with flexible gas hose connection and Hose assemblies for use with cooking appliances shall
be certified as conforming to AS/NZS 1869 and be Class B or Class D. Quick connect devices if provided, shall be certified to AG 212 (to be AS
4627).