2.0 Installation
1. Remove service compartment cover
2. Connect electrical wiring, following the below wiring diagram.
After connecting wires, use a multimeter to check active, Neutral & Earth connections
3. Reinstall service compartment cover
4. Secure wiring cable by fastening the cable gland nut
2.3.2 Wiring (KB061WT / KB101WT)
PE
N5
N4
Yellow/Green: Earth
Neutral
L1
L3
L2
Phases
L1
N5
PE
AC 415V
3Ø + N + E
AC 230V
1Ø + N + E
L1
L2
L3
N4
N5
PE
x3
KB061WT
KB101WT
KBG061WT
KBG101WT
Weight
92
110
96
118
Power (kW)
7.9kW
415V 3Ø + N + E (3 x 11A)
14.8kW
415V 3Ø + N + E (3 x 21A)
1.3kW
230V 1Ø + N + E
10A Plug and Lead
1.6kW
230V 1Ø + N + E
10A Plug and Lead