background image

Boat Hull

Floor support

Floor support

Tank

Deck

Clearance
height for

installation

Electrical connections for the NMEA2000 option are as follows:

RED

       = Power

BLACK

  = Ground

WHITE

  = CAN-H

BLUE

     = CAN-L

BARE

     = Shield

The Gill 7014 Waste Liquid Level Sensor is a sealed unit and any damage to the black 

sleeving on the probe will result in failure of the sensor.

Do not

 attempt to cut the sensor to length or bend the sensor probe. Both actions will 

result in sensor failure and invalidate the warranty.

If the sensor has been used in Blackwater or any other materials, special procedures 

must be followed. You 

must 

contact Gill Sensors & Controls for instructions. 

Contact details can be found at the end of this guide.

Hello.

Here is a quick guide to getting your sensor up and running.

Supplied with 
M12, 5-way Micro 
NMEA2000 ‘male’
connector

7014 WASTE LIQUID

 LEVEL SENSOR

 

Sensors & Controls

7014-30-042 Iss 3

Ensure you have sufficient

 

clearance to get the sensor into the

tank without bending the probe or scraping the black sleeve 

on sharp edges.

More information at 

gillsc.com

 [email protected]

T

  +44 (0)1590 613900

E & OE

On the top of the sensor flange, remove the retaining screw and cover to 

access the USB connection. There is an O-ring seal around the cover which 

makes it resistive to removal. When replacing the cover please ensure that a 

good seal is re-established.  

Go to the Gill website 

gillsc.com/support

 to download the configuration 

software. The User Manual covers sensor set-up and configuration.

To setup and configure the

 

sensor you will require a standard USB lead - 

Type A to Micro B.

INSTALLATION GUIDANCE

CONFIGURATION

Содержание 7014

Страница 1: ...or failure and invalidate the warranty If the sensor has been used in Blackwater or any other materials special procedures must be followed You must contact Gill Sensors Controls for instructions Contact details can be found at the end of this guide Hello Here is a quick guide to getting your sensor up and running 7014 WASTE LIQUID LEVEL SENSOR Sensors Controls 3 Ensure you have sufficient clearan...

Страница 2: ...e face is flush to the top of the tank Ensure gasket is centered under the sensor flange Using 46mm spanner tighten to 50Nm If it is not possible to create a bevel then the gasket should be used Remove the O ring and fit the gasket over the thread mount black side up Ensure the gasket is centered under the sensor and tighten to a torque of 50Nm Floor panels Clearance when installed Require 90mm mi...

Страница 3: ...f 2 metres the sensor does not require any supports inside the tank Analogue Output options are as follows RED Power BLACK Ground WHITE Measurement BLUE Switch BARE Shield Indicator Gauge The sensor requires a DC power supply between 6V and 32V It has reverse polarity protection to 32V and over voltage protection to 50V 5 minutes ELECTRICAL CONNECTIONS ...

Страница 4: ...On the top of the sensor flange remove the retaining screw and cover to access the USB connection There is an O ring seal around the cover which makes it resistive to removal When replacing the cover please ensure that a good seal is re established Go to the Gill website gillsc com support to download the configuration software The User Manual covers sensor set up and configuration To setup and co...

Отзывы: