FlexPay NC3L Wide Installation and maintenance
39
9.
POWER-ON PROCEDURE F OR
TEMPERATURES LOWER T HAN 0 °C
1. Before starting the heating procedures, make sure that the NC3L internal power button is switched off.
2. Energize the AC supply line from the kiosk.
3. Make sure that the heating system (h fan) is correctly working.
4. Close the NC3L doors.
5. Wait 2 hours until manual heating procedure will be completed.
6. Open the NC3L printer and reader doors and switch on power button.
7. Close the NC3L doors.
10.
CONNECTIONS SPECIFICATIONS
1 0 . 1 .
A C M A I N S
Power supply:
230 V +10% -15%; 50 +/- 2 Hz
.
Input current.: 3,2 A.
Cable type:
cable suitable for buried installation, oil resistant and in compliance with EN/IEC 60079-14 or
EN13617-1, 4P+G or 2x 2P+G size 1,5 - 4 mm
².
1 0 . 2 .
E T H E R N E T
Cable type Ethernet LAN: Approved for CAT5 (or higher), shielded twisted pair (STP); cable approved for
buried installation with oil resistant oversheath.