Up counting mode
In this mode, the counter counts up continuously from 0 to the counter-reload value, which is
defined in the TIMERx_CAR register, in a count-up direction. Once the counter reaches the
counter reload value, the counter restarts from 0. If the repetition counter is set, the update
events will be generated after (TIME1) times of overflow. Otherwise the update
event is generated each time when overflows. The counting direction bit DIR in the
TIMERx_CTL0 register should be set to 0 for the up counting mode.
Whenever, if the update event software trigger is enabled by setting the UPG bit in the
TIMERx_SWEVG register, the counter value will be initialized to 0 and generates an update
event.
If set the UPDIS bit in TIMERx_CTL0 register, the update event is disabled.
When an update event occurs, all the registers (repetition counter, auto reload register,
prescaler register) are updated.
Figure 17-56. Up-counter timechart, PSC=0/1
show some examples of the counter
behavior for different clock prescaler factor when TIMERx_CAR=0x63.
Figure 17-56. Up-counter timechart, PSC=0/1
CEN
CNT_CLK(PSC_CLK)
CNT_REG
5E
5F
60
61
62
63
00
01
02
03
04
05
06
07
Update event (UPE)
Update interrupt flag (UPIF)
CNT_REG
5F
60
Update event (UPE)
Update interrupt flag (UPIF)
Hardware set
Software clear
Hardware set
PSC = 0
PSC = 1
TIMER_CK
08
63
62
61
00
01
02
03
CNT_CLK(PSC_CLK)
Содержание GD32W515 Series
Страница 1: ...GigaDevice Semiconductor Inc GD32W51x Arm Cortex M33 32 bit MCU User Manual Revision 1 0 Nov 2021 ...
Страница 66: ...GD32W51x User Manual 66 Bits Fields Descriptions 31 0 UNIQUE_ID 95 64 Unique device ID ...
Страница 389: ...GD32W51x User Manual 389 The FWDGT timeout can be more accurate by calibrating the IRC32K ...
Страница 504: ...GD32W51x User Manual 504 ...
Страница 710: ...GD32W51x User Manual 710 ...