GD32F403xx User Manual
354
x Output prepare signal) is defined by setting the CHxCOMCTL filed. The OxCPRE signal has
several types of output function. These include, keeping the original level by setting the
CHxCOMCTL field to 0x00, set to 1 by setting the CHxCOMCTL field to 0x01, set to 0 by
setting the CHxCOMCTL field to 0x02 or signal toggle by setting the CHxCOMCTL field to
0x03 when the counter value matches the content of the TIMERx_CHxCV register.
The PWM mode 0 and PWM mode 1 outputs are also another kind of OxCPRE output which
is setup by setting the CHxCOMCTL field to 0x06/0x07. In these modes, the OxCPRE signal
level is changed according to the counting direction and the relationship between the counter
value and the TIMERx_CHxCV content. With regard to a more detail description refer to the
relative bit definition.
Another special function of the OxCPRE signal is a forced output which can be achieved by
setting the CHxCOMCTL field to 0x04/0x05. Here the output can be forced to an
inactive/active level irrespective of the comparison condition between the counter and the
TIMERx_CHxCV values.
Master-slave management
The TIMERx can be synchronized with a trigger in several modes including the Restart mode,
the Pause mode and the Event mode which is selected by the SMC [2:0] in the
TIMERx_SMCFG register. The trigger input of these modes can be selected by the TRGS
[2:0] in the TIMERx_SMCFG register.
Table 16-6
.
Slave mode example table
Mode Selection
Source Selection
Polarity Selection
Filter and Prescaler
LIST
SMC[2:0]
3'b100 (restart mode)
3'b101 (pause mode)
3'b110 (event mode)
TRGS[2:0]
000: ITI0
001: ITI1
010: ITI2
011: ITI3
100: CI0F_ED
101: CI0FE0
110: CI1FE1
111: Reserved
If you choose the CI0FE0 or
CI1FE1,
configure
the
CHxP and CHxNP for the
polarity
selection
and
inversion.
For the ITIx no filter and
prescaler can be used.
For the CIx, configure
Filter by CHxCAPFLT, no
prescaler can be used.
Exam1
Restart mode
The counter can be
clear and restart when a
rising trigger input.
TRGS[2:0]=3’b000
ITI0 is the
selection.
-
For ITI0, no polarity selector
can be used.
-
For the ITI0, no filter and
prescaler can be used.