Gigabyte T181-Z70 Скачать руководство пользователя страница 111

- 111 -

BIOS Setup

5-3-7  SOC Miscellaneous Control

Parameter

Description

SOC Miscellaneous Control

ABL Console Out Control

Enable/Disable the ConsoleOut function for ABL. 
Options available: Auto, Enabled, Disabled. Default setting is 

Auto

.

ABL PMU message 
Control

(Note)

To Control the total number of PMU debug messages.
Options available: Auto, Enabled, Disabled. Default setting is 

Auto

.

(Note)  This item appears when 

ABL Console Out Control 

is set to 

Enabled

.

Содержание T181-Z70

Страница 1: ...T181 Z70 AMD EPYC 7003 server rack 1U 4 x GPU Card Slots User Manual Rev B00...

Страница 2: ...allation configuration and use this product motherboard covering hardware BIOS Service Guide detailed information steps about the installation configuration and use of this product server barebones co...

Страница 3: ...sistance pleasecontactyourGIGABYTEsalesrepresentative YoumayalsomessageGIGABYTEserverdirectlybyemail Facebookortwitter Email server grp gigabyte com Facebook https www facebook com gigabyteserver Twit...

Страница 4: ...uide NOTE Gives bits and pieces of additional information related to the current topic CAUTION Gives precautionary measures to avoid possible hardware or software problems WARNING Alerts you to any da...

Страница 5: ...items placed against it Pay particular attention to the plug electrical outlet and the point where the cord extends from the server WARNING To reduce the risk of personal injury from hot surfaces allo...

Страница 6: ...stem and discon nect the cables attached to the system before servicing it Otherwise personal injury or equipment damage can result Electrostatic discharge ESD and ESD protection ESD can damage drives...

Страница 7: ...care to grip with but not squeeze the pliers or other tool used to remove a jumper or the pins on the board may bend or break CAUTION Risk of explosion if battery is replaced incorrectly or with an in...

Страница 8: ...4 Installing the CPU 23 3 5 Installing the Memory 25 3 5 1 Eight Channel Memory Configuration 25 3 5 2 Installing the Memory 26 3 5 3 Processor and Memory Module Matrix Table 26 3 6 Installing the GPU...

Страница 9: ...col Policy 67 5 2 15 Tls Auth Configuration 68 5 2 16 iSCSI Configuration 69 5 2 17 Intel R Ethernet Controller X550 70 5 2 18 VLAN Configuration 72 5 2 19 MAC IPv4 Network Configuration 73 5 2 20 MAC...

Страница 10: ...ty Menu 125 5 7 1 Secure Boot 126 5 8 Boot Menu 128 5 8 1 UEFI NETWORK Drive BBS Priorities 130 5 8 2 UEFI Application Boot Priorities 131 5 9 Save Exit Menu 132 5 10 BIOS POST Beep code AMI standard...

Страница 11: ...dry and first touch a metal object to eliminate static electricity Prior to installing the motherboard please have it on top of an antistatic pad or within an electrostatic shielding container Before...

Страница 12: ...odules up to 128GB supported 3DS RDIMM LRDIMM modules up to 256GB supported Memory speed Up to 3200 2933 MHz Note Follow BIOS setting and memory QVL list if running 3200 Mhz with 2DPC LAN 2 x 1GbE LAN...

Страница 13: ...ower Consumption Power Control LDAP AD RADIUS Support Backup Restore Configuration Remote BIOS BMC CPLD Update Event Log Filter User Management Media Redirection Settings PAM Order Settings SSL Settin...

Страница 14: ...2 5 NVME HDD CPU_1 80 PORT COM VGA front SDRAM 2Gb SPI 64MB SPI Flash 32MB ASPEED AST2500 2 x USB3 0 front 2 x PCIe x16 for GPGPU PCIe3 0 x16 PCIe3 0 x16 PCIe3 0 x1 PCIe3 0 x2 PCIe3 0 x16 PCIe3 0 x4 2...

Страница 15: ...5 SATA HDD Bay x 4 0 to 3 2 VGA Port 3 Riser Card Slot x 2 4 Front Panel LEDs and Buttons 5 USB 3 0 Port x 2 6 10 100 1000 Server Management LAN Port 7 1 GbE LAN Port x 2 Please go to section 2 3 Fron...

Страница 16: ...ess this button to reset system 4 NMI Button N A N A Singal attention for non recoverable hardware errors 5 HDD Status LED Green On HDD locate Blink HDD access Amber On HDD error Green Amber Blink HDD...

Страница 17: ...eed LED Yellow On 1 Gbps data rate Green On 100 Mbps data rate N A Off 10 Mbps data rate 2 1 GbE Link Activity LED Green On Link between system and network or no access Blink Data transmission or rece...

Страница 18: ...n Back Panel Disk LED Removed HDD Slot Green ON 1 OFF BLINK 2 BLINK 2 OFF OFF OFF ON OFF ON 1 OFF OFF ON OFF ON Low Speed 2 Hz 3 3 OFF OFF Green Amber Green ON 1 OFF Green OFF OFF Amber Amber OFF OFF...

Страница 19: ...are working inside the system case If possible wear a grounded wrist strap when you are working inside the system case Alternatively discharge any static electricity by touching the bare metal system...

Страница 20: ...the system cover Make sure the system is not turned on or connected to AC power Follow these instructions to remove the system cover 1 Loosen the thumbnail screw securing the system cover 2 Slide the...

Страница 21: ...the air duct to the grooves at the rear side of the HDD tray brackets Push down the air duct into chassis until it firmly seats 3 To install the right air duct align the air duct to the grooves at the...

Страница 22: ...tions to remove the Heatsink 1 Loosen four captive screws securing the heatsink to the system 2 Lift and remove the heatsink from the system 3 Repeat steps 1 to 2 to remove the other heatsink from the...

Страница 23: ...installing components may cause serious damage Do not attempt the procedures described in the following sections unless you are a quali fied service technician Follow these instructions to install the...

Страница 24: ...PU cover into place over the CPU socket 7 Tighten the CPU cover screws in sequential order 1g2g3 to secure the CPU cover in place 6 1 1 3 3 2 2 7 Tighten the CPU cover screws in sequential order 1g2g3...

Страница 25: ...y of the same capacity brand speed and chips be used Always turn off the system and unplug the power cord from the power outlet before installing the memory to prevent hardware damage Memory modules h...

Страница 26: ...M memory module vertically into the DIMM slot and push it down 2 Close the plastic clip at both edges of the DIMM slots to lock the DIMM module 3 Reverse the installation steps when you want to remove...

Страница 27: ...1R 3200 1R 1R 2933 2R or 2DR 3200 1R 2R or 2DR 2933 2R or 2DR 2R or 2DR 2933 LRDIMM 4DR 3200 4DR 4DR 2933 2S2R 4 Ranks 3200 2S4R 8 Ranks 3200 2S2R 4 Ranks 2S2R 4 Ranks 2933 2S4R 8 Ranks 2S4R 8 Ranks...

Страница 28: ...the bracket 2 Remove the four screws securing the air duct bracket from the left and right side of the bracket and remove the air duck bracket from the system 1 2 2 Read the following guidelines befor...

Страница 29: ...bracket you want to install the GPU card from the system 3 4 Remove the cushion sponge next to the PCIe cable as indicated 5 Disconnect the PCIe cable from the motherboard connector 6 Remove the three...

Страница 30: ...card bracket and insert the GPU card into the riser board connector ensuring that the GPU card is properly connected to the riser board connector 8 Secure the GPU card with two screws 7 8 9 Reverse s...

Страница 31: ...disconnected from the server prior to installing a PCI card Failure to observe these warnings could result in personal injury or damage to equipment Follow these instructions to install the PCI Expans...

Страница 32: ...all the replacement fan module GPU Fan 11 Fan 12 GPU Fan 15 Fan 16 GPU Fan 3 Fan 4 CPU Fan 7 Fan 8 CPU Fan 1 Fan 2 GPU Fan 7 Fan 8 GPU Fan 9 Fan 10 CPU Fan 3 Fan 4 CPU Fan 5 Fan 6 GPU Fan 13 Fan 14 GP...

Страница 33: ...rted incorrectly Make sure that the HDD is connected to the HDD connector on the backplane Follow these instructions to install the 2 5 HDD 1 Press the release button 2 Extend the locking lever 3 Pull...

Страница 34: ...System Hardware Installation 34 1 2 3 No Suggest Cable No Suggest Cable 1 LAN Cable 2 VGA Cable 3 USB 3 0 Cable 3 10 Cable Routing 3 10 1 Motherboard to Front Panel Cable Routing...

Страница 35: ...ard to Power Board 1 2 3 4 5 No Suggest Cable No Suggest Cable 1 2 x 9 Pin CPU0 Power Cable red 2 2 x 7 Pin System Power Cable purple 3 Power Board Signal Cable blue 4 2 x 9 Pin System Fan Power Cable...

Страница 36: ...Backplane Power Cable 2 HDD Backplane Signal Cable No Suggest Cable No Suggest Cable 3 HDD Backplane NVMe Cable 0 blue top 4 HDD Backplane NVMe Cable 1 yellow bottom 5 HDD Backplane NVMe Cable 2 brow...

Страница 37: ...37 System Hardware Installation 7 No Suggest Cable No Suggest Cable 7 HDD Backplane SATA Cable...

Страница 38: ...System Hardware Installation 38 1 1 1 1 2 2 2 2 No Suggest Cable No Suggest Cable 1 GPU Power Cable red 2 PCIe Extension Cable green 3 10 4 GPU Card PCIe x16 Cable Routing...

Страница 39: ...llation 3 10 5 CPU and GPU Fan Cable Routing 2 2 2 2 1 1 1 1 1 1 1 1 No Suggest Cable No Suggest Cable 1 GPU Fan Power Cable 2 CPU Fan Power Cable NOTE Cable with red wire corresponds to motherboard c...

Страница 40: ...System Hardware Installation 40 This page intentionally left blank...

Страница 41: ...ector 1GbE LAN Signal 6 2 x 7 Pin System Power Connector 7 SlimLine Connector SATA 6Gb s Signal 8 2 x 9 Pin CPU0 Power Connector 9 SlimLine Connector NVMe Signal 10 SlimLine Connector NVMe Signal 11 P...

Страница 42: ...Motherboard Components 42 4 2 Jumper Setting S S S S S S S S BIOS Recovery Jumper Clear CMOS Jumper Clear CMOS CLR_CMOS Enable Default 1 2 3 Enable Default 1 2 3 BIOS Recovery BIOS_RCVR...

Страница 43: ...with caution Inadequate BIOS flashing may result in system malfunction It is recommended that you not alter the default settings unless you need to to prevent system instability or other unexpected re...

Страница 44: ...the North Bridge Server Management Server additional features enabled disabled setup menus Security Change set or disable supervisor and user password Configuration supervisor password allows you to...

Страница 45: ...displayed on the bottom line of the Main Menu Submenu Help While in a submenu press F1 to display a help screen General Help of function keys available for the menu Press Esc to exit the help screen H...

Страница 46: ...of the installed memory Memory Frequency Note3 Displays the frequency information of the installed memory VR Information Version Displays VR version information AGESA PI Version PI Version Displays A...

Страница 47: ...Menu The Advanced Menu displays submenu options for configuring the function of various hardware components Select a submenu item then press Enter to access the related submenu screen When Boot Mode S...

Страница 48: ...BIOS Setup 48 When Boot Mode Select is set to Legacy in the Boot Boot Mode Select section...

Страница 49: ...le BIOS support for security device OS will not show security device TCG EFI protocol and INT1A interface will not be available Options available Enable Disable Default setting is Enable SPI TPM Suppo...

Страница 50: ...BIOS Setup 50 5 2 2 PSP Firmware Versions The PSP Firmware Versions page displays the basic PSP firmware version information Items on this window are non configurable...

Страница 51: ...nBrd Ext VGA Select Note Selects between onboard or external VGA support Options available Auto Onboard External Default setting is Onboard Note This configurable option will be displayed when Boot Mo...

Страница 52: ...4 AST2500 Super IO Configuration Parameter Description AST2500 Super IO Configuration Super IO Chip Displays the super IO chip information Serial Port 1 2 Configuration Press Enter for configuration...

Страница 53: ...ion Wake System from S5 Note1 Enable Disable system wake on alarm event Options available Disabled Fixed Time When Fixed Time enabled system will wake on the hr min sec specified Default setting is Di...

Страница 54: ...LAN Console Redirection Settings Press Enter to configure advanced items Please note that this item is configurable when COM1 Serial Over LAN COM2 Console Redirection is set to Enabled Terminal Type...

Страница 55: ...2 Default setting is 1 Flow Control Flow control can prevent data loss from buffer overflow When sending data if the receiving buffers are full a stop signal can be sent to stop the data flow Once the...

Страница 56: ...S Console Redirection Note EMS console redirection allows the user to configure Console Redirection Settings to support Out of Band Serial Port management Options available Enabled Disabled Default se...

Страница 57: ...a loss from buffer overflow When sending data if the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty a start signal can be sent to re start the fl...

Страница 58: ...the CPU Virtualization Options available Enabled Disabled Default setting is Enabled SMEE Controls the Secure Memory Encryption Enable SMEE function Options available Enabled Disabled Default setting...

Страница 59: ...59 BIOS Setup 5 2 8 PCI Subsystem Settings...

Страница 60: ...ailable Auto Maximum Gen1 Gen2 Gen3 Default setting is Auto Onboard LAN Controller Note2 Enable Disable the onboard LAN devices Options available Enabled Disabled Default setting is Enabled Onboard LA...

Страница 61: ...le Auto Enabled Disabled Default setting is Enabled XHCI Hand off Enable Disable the XHCI USB 3 0 Hand off support Options available Enabled Disabled Default setting is Enabled USB Mass Storage Driver...

Страница 62: ...r a Root port it is 100 ms for a Hub port the delay is taken from Hub descriptor Options available Auto Manual Default setting is Auto Mass Storage Devices AMI Virtual CDROM0 1 00 AMI HDisk0 1 00 Gene...

Страница 63: ...6 PXE Support Enable Disable the Ipv6 PXE feature Options available Enabled Disabled Default setting is Enabled Ipv6 HTTP Support Enable Disable the Ipv6 HTTP feature Options available Enabled Disable...

Страница 64: ...BIOS Setup 64 5 2 11 NVMe Configuration Parameter Description NVMe Configuration Displays the NVMe devices connected to the system...

Страница 65: ...65 BIOS Setup 5 2 12 SATA Configuration Parameter Description SATA Configuration Displays the installed HDD devices information System will automatically detect HDD type...

Страница 66: ...BIOS Setup 66 5 2 13 UEFI POST LOGO Configuration Parameter Description UEFI Configuration Select output device type...

Страница 67: ...67 BIOS Setup 5 2 14 AMI Graphic Output Protocol Policy Parameter Description CPU0 1 Press Enter to view the memory configuration status related to CPU 0 1...

Страница 68: ...guration of advanced items Enroll Cert Press Enter to enroll a certificate Enroll Cert Using File Cert GUID Input digit character in 1111111 2222 3333 4444 1234567890ab format Commit Changes and Exit...

Страница 69: ...nitiator Name Press Enter and name iSCSI Initiator Only IQN format is accecpted Range from 4 to 223 Add an Attempt Press Enter to configure advanced items Delete Attempts Press Enter to configure adva...

Страница 70: ...BIOS Setup 70 5 2 17 Intel R Ethernet Controller X550...

Страница 71: ...rt by blinking the associated LED Press the numeric keys to adjust desired values UEFI Driver Displays the technical specifications for the Network Interface Controller Adapter PBA Displays the techni...

Страница 72: ...VLAN Press the keys to increase or decrease the desired values The valid range is from 0 to 4094 Priority Sets 802 1Q Priority for a new VLAN or an existing VLAN Press the keys to increase or decreas...

Страница 73: ...ote Options available Enabled Disabled Default setting is Enabled Local IP Address Note Press Enter to configure local IP address Local NetMask Note Press Enter to configure local NetMask Local Gatewa...

Страница 74: ...for the device The string is colon separated e g ff dd 88 66 cc 1 2 3 DAD Transmit Count The number of consective Neighbor solicitation messages sent while performing Duplicate Address Detection on a...

Страница 75: ...tup 5 3 AMD CBS Menu AMD CBS menu displays submenu options for configuring the CPU related information that the BIOS automatically sets Select a submenu item then press Enter to access the related sub...

Страница 76: ...H cloak individual banks and mask deferred error interrupts from each bank Options available Auto Enabled Disabled Default setting is Auto Core Performance Boost Enable Disable the Core Performance Bo...

Страница 77: ...ions available Auto Enabled Disabled Default setting is Auto SNP Memory RMP Table Coverage Enabled Enter system memory is covered Options available Auto Enabled Disabled Custom Default setting is Auto...

Страница 78: ...pt or decline enabling CCDs processor cores and threads When accepted you can control the number of CCDs to be used the number of cores to be used and whether to enable or disable Simultaneous Multith...

Страница 79: ...le Disable Default setting is Auto L1 Region Prefetcher Use memory access history to fetch additional lines when the data access for a given instruction tends to be followed by other data accesses Opt...

Страница 80: ...BIOS Setup 80 5 3 1 3 Core Watchdog Parameter Description Core Watchdog Core Watchdog Timer Enable Enable Disable CPU Watchdog Timer Options available Auto Enabled Disabled Default setting is Auto...

Страница 81: ...isable DF Sync Flood propagation Options available Auto Sync flood disabled Sync flood enabled Default setting is Auto Frezze DF module queues on error Options available Auto Enabled Disabled Default...

Страница 82: ...fault setting is Auto Poison scrubber control Enable Disable the Poison scrubber control feature Options available Auto Enabled Disabled Default setting is Auto Redirect scrubber control Enable Disabl...

Страница 83: ...remap Enable Disable to remap DRAM out of the space just below the 1TB boundary The ability to remap depends on DRAM configuration NPS and interleaving selection and may not always be possible Options...

Страница 84: ...ptions available Auto Enabled Disabled Default setting is Auto ACPI SLIT Distance Control Determines how the SLIT distances are declared Options available Auto Manual Default setting is Auto ACPI SLIT...

Страница 85: ...ult setting is Auto 4 link xGMI max speed Specifies the max speed of 4 link xGMI Options available Auto 10 667Gbps 13Gbps 16Gbps 18Gbps Default setting is 10 667Gbps 3 link xGMI max speed Specifies th...

Страница 86: ...ommon Options DDR4 Common Options Press Enter for configuration of advanced items DRAM Memory Mapping Press Enter for configuration of advanced items NVDIMM Press Enter for configuration of advanced i...

Страница 87: ...el at 3200MHz function select Accept at warning message change Overclock from Auto to Enabled and then set memory speed to 3200MHz DRAM Controller Configuration Press Enter to configure DRAM Controlle...

Страница 88: ...nd UrgRefLimit DRAM Maximum Activate Count Options available Auto Unlimited MC 200K 300K 400K 500K 600K 700K Default setting is Auto DRAM Refresh Rate Options available 7 8 usec 3 9 usec Default setti...

Страница 89: ...guration CAD Bus Timing User Controls Setup time on CAD bus signals to Auto or Manual Options available Auto Manual Default setting is Auto CAD Bus Drive Strength User Controls Drive Strength on CAD b...

Страница 90: ...1 3 Data Bus Configuration Parameter Description Data Bus Configuration Data Bus Configuration User Controls Specifies the mode for drive strength to Auto or Manual Options available Auto Manual Defa...

Страница 91: ...ion Options available Auto Enabled Disabled Default setting is Auto Max Parity Error Replay Configures the Max Parity Error Replay 0 0x3f Default setting is 8 Please note that this item is configurabl...

Страница 92: ...ms DRAM ECC Symbol Size Configures the DRAM ECC Symbol Size Options available Auto x4 x8 x16 Default setting is Auto DRAM ECC Enable Enable Disable DRAM ECC When set to Auto it will set ECC to enable...

Страница 93: ...ameter Description Security TSME Enable Disable Transparent SME Options available Auto Enabled Disabled Default setting is Auto Data Scramble Enable Disable Data Scrambling Options available Auto Enab...

Страница 94: ...Training Press Enter to configure PMU Training DFE Traing Enable Disable DDR power down mode Options available Auto Enabled Disabled Default setting is Auto FFE Write Training Auto Enabled Disabled D...

Страница 95: ...No help string Options available Auto Enabled Disabled Default setting is Auto BankGroupSwapAlt Configures the BankGroupSwapAlt Options available Auto Enabled Disabled Default setting is Auto Address...

Страница 96: ...BIOS Setup 96 5 3 3 3 NVDIMM Parameter Description NVDIMM Disable NVDIMM N feature for memory margin tool Options available No Yes Default setting is No...

Страница 97: ...Mode Data Eye Mode Default setting is Auto MBIST Aggressors Note Enable Disable MBIST Aggressor test Options available Auto Enabled Disabled Default setting is Auto MBIST Per Bit Slave Die Reporting...

Страница 98: ...function Options available Enabled Disabled Default setting is Disabled Aggressor Static Lane Select Upper 32 bits This item is configurable when Aggressor Static Lane Control is set to Enabled Aggre...

Страница 99: ...oltage Sweep 1D Timing Sweep 2D Full Data Eye Worst Case Margin Only Default setting is Worst Case Margin Only Worst Case Margin Granularity Configures Worst Case Margin Granularity Options available...

Страница 100: ...umeration ARI Forwarding Enable for each downstream port Options available Auto Enabled Disabled Default setting is Auto PCIe Ten Bit Tag Support Enable Disable PCIe ten bit tags for supported devices...

Страница 101: ...nfigures Preferred IO Device Options available Auto Manual Default setting is Auto Loopback Mode Enabled Disabled PCIe Loopback mode Options available Auto Enabled Disabled Default setting is Auto CV...

Страница 102: ...ontrol Selects use the fused TDP or set customized TDP TDP is used to define the RC thermal model only Options available Auto Manual Default setting is Auto cTDP Display cTDP information EfficiencyMod...

Страница 103: ...isable Options available Auto Enabled Disabled Default setting is Auto DLMM Support Select DLMM support enable or disable Options available Auto Enabled Disabled Default setting is Auto BoostFmaxEn Op...

Страница 104: ...it of 0 indicates LOW serverity NBIO SyncFlood Generation The value may be used to mask SyncFlood caused by NBIO RAS options Options available Auto Enabled Disabled Default setting is Auto NBIO SyncFl...

Страница 105: ...Default setting is Disabled SLINK Read Response Error Handling Options available Enabled Trigger MCOMMIT Error Log Errors in MCA Default setting is Log Errors in MCA Log Poison Data from SLINK Enable...

Страница 106: ...rameter Description FCH Common Options AC Power Loss Options Press Enter for configuration of advanced items FCH RAS Options Press Enter for configuration of advanced items Miscellaneous Options Press...

Страница 107: ...Setup 5 3 5 1 AC Power Loss Options Parameter Description AC Power Loss Options AC Loss Control Selects the AC Loss Control Method Options available Power Off Power On Last State Default setting is P...

Страница 108: ...Link RAS Support Enable Disable the ALink RAS Support Options available Auto Enabled Disabled Default setting is Auto Reset after sync flood Enables AB to forward downstream sync flood message to syst...

Страница 109: ...109 BIOS Setup 5 3 5 3 Miscellaneous Options Parameter Description Miscellaneous Options Boot Time Enable Options available Auto Enabled Disabled Default setting is Auto...

Страница 110: ...TB Enable Options available Auto Enable Default setting is Auto Socket 0 P1 NTB Enable Options available Auto Enable Default setting is Auto Socket 0 P2 NTB Enable Options available Auto Enable Defaul...

Страница 111: ...able Disable the ConsoleOut function for ABL Options available Auto Enabled Disabled Default setting is Auto ABL PMU message Control Note To Control the total number of PMU debug messages Options avai...

Страница 112: ...er Description Workload Tuning Workload Profile Select the profile for different workloads Default setting is Auto Performance Tracing Enable to allow capturing performance traces Options available Au...

Страница 113: ...ing for protect ROM part Options available Enabled Disabled Default setting is Disabled iLA TraceMemoryEn Reserved 1M bytes MMIO space on 1M boundary when iLA TraceMemoryEn disabled Options available...

Страница 114: ...eriod GHES Notify Type Selects the Notification type for deferred corrected errors Options available Polled SCI Default setting is Polled GHES UnCorr Notify Type Selects the Notification type for unco...

Страница 115: ...R Notify Type Selects the Notification type for CCIX deffered error Options available Polled SCI Default setting is Polled CCIX GHES Corrected Err Notify Type Selects the Notification type for CCIX co...

Страница 116: ...r to access the related submenu screen Parameter Description PCIe Compliance Mode Options available On Off Default setting is Off Program All VR Enable Disable program all VR on MB Options available E...

Страница 117: ...r Description North Bridge Configuration Memory Information Total Memory Displays the total memory information CPU0 Information Press Enter to view information related to CPU 0 CPU1 Information Press...

Страница 118: ...BIOS Setup 118 5 5 2 Fabric Resource Parameter Description Fabric Resource Socket 0 1 NBIO_ PCIe Bus Number Change Socket 0 1 NBIO_ PCIe Bus Number...

Страница 119: ...Default setting is Do Nothing OS Watchdog Timer Enable Disable OS Watchdog Timer function Options available Enabled Disabled Default setting is Disabled OS Wtd Timer Timeout Configures OS Watchdog Tim...

Страница 120: ...d 2 minutes 4 minutes 6 minutes Default setting is 2 minutes System Event Log Press Enter to configure advanced items View FRU Information Press Enter to view the FRU information BMC network configura...

Страница 121: ...SEL Choose options for erasing SEL Options available No Yes On next reset Yes On every reset Default setting is No When SEL is Full Choose options for reactions to a full SEL Options available Do Not...

Страница 122: ...Information The FRU page is a simple display page for basic system ID information as well as System product information Items on this window are non configurable Note The model name will vary depends...

Страница 123: ...g is DynamicBmcDhcp Station IP address Displays IP Address information Subnet mask Displays Subnet Mask information Please note that the IP address must be in three digitals for example 192 168 000 00...

Страница 124: ...ork during BIOS phase Options available Unspecified Disable Enable Default setting is Enable IPv6 BMC Lan IP Address Source Selects to configure LAN channel parameters statically or dynamically by BIO...

Страница 125: ...ll settings in the Setup Utility User Password Entering this password will restrict a user s access to the Setup menus To enable or disable this field a Administrator Password must first be set A user...

Страница 126: ...oting process to be pre signed with valid digital certificates This way the system knows all files being loaded before Windows loads to the login screen have not been tampered with When set to Standar...

Страница 127: ...Key Exchange Keys KEK Displays the current status of the Key Exchange Key Database KEK Press Enter to configure a new KEK or load additional KEK from storage devices Options available Set New Append A...

Страница 128: ...er of seconds to wait for setup activation key 65535 0xFFFF means indefinite waiting Press the numeric keys to input the desired values Bootup NumLock State Enable Disable the Bootup NumLock function...

Страница 129: ...re the boot priority By default the server searches for boot devices in the following sequence 1 Hard drive 2 CD COM DVD drive 3 USB device 4 Network 5 UEFI UEFI Network Drive BBS Priorities Press Ent...

Страница 130: ...ities The UEFI network drive BBS priorities submenu allows you to specify the boot device priority from the available UEFI network drives during system boot up BIOS setup will display an error message...

Страница 131: ...orities The UEFI application boot priorities submenu allows you to specify the boot device priority from the available UEFI applications during system boot up BIOS setup will display an error message...

Страница 132: ...e so far to any of the setup options Options available Yes No Default Options Restore Defaults Loads the default settings for all BIOS setup parameters Setup Defaults are quite demanding in terms of r...

Страница 133: ...L was not found 3 DXE Core Firmware Volume was not found 4 Recovery failed 4 S3 Resume failed 7 Reset PPI is not available 5 10 2 DXE Beep Codes of Beeps Description 1 Invalid password 4 Some of the A...

Страница 134: ...BIOS Setup 134 This page intentionally left blank...

Отзывы: