System Hardware Installation
- 35 -
3-7-2 OCP 2.0
Follow these instructions to install an OCP 2.0 mezzanine card:
1. Loosen the thumbscrew on the riser bracket
2. Lift up the riser bracket out of system.
3. Remove the screw securing the mezzanine card slot cover.
4. Remove the slot cover from the system.
5. Install the OCP 2.0 slot cover to the system
6. Secure the OCP 2.0 slot cover with the screw.
7.
Insert the OCP 2.0 mezzanine card into the compartment ensuring that the card is firmly connected
to the connector on the motherboard.
8. Secure the OCP 2.0 mezzanine card into the system with three screws.
9. Reverse the previous steps to replace the OCP 2.0 mezzanine card.