background image

BIOS Setup

- 52 -

5-2-2  PSP Firmware Versions

The PSP Firmware Versions page displays the basic PSP firmware version information. Items on this window 
are non-configurable.

Содержание G221-Z30

Страница 1: ...G221 Z30 HPC Server 2U 2 x GPU Server User Manual Rev 1 0 ...

Страница 2: ... and BIOS User Guide detailed information about the installation use of an add on hardware or software component e g BMC firmware rail kit compatible with this product Quick Installation Guide a short guide with visual diagrams that you can reference easily for installation purposes of this product e g motherboard server barebones Please see the support section of the online product page to check ...

Страница 3: ...guide NOTE Gives bits and pieces of additional information related to the current topic CAUTION Gives precautionary measures to avoid possible hardware or software problems WARNING Alerts you to any damage that might result from doing or not doing specific actions ...

Страница 4: ...e risk of personal injury from hot surfaces allow the drives and the internal system components to cool before touching them WARNING This server is equipped with high speed fans Keep away from hazardous moving fan blades during servicing WARNING This equipment is not suitable for use in locations where children are likely to be present WARNING This equipment is intended to be used in Restrict Acce...

Страница 5: ...charge ESD and ESD protection ESD can damage drives boards and other parts We recommend that you perform all procedures in this chapter only at an ESD workstation If one is not available provide some ESD protection by wearing an antistatic wrist strap attached to chassis ground any unpainted metal surface on the server when handling parts ESD and handling boards Always handle boards carefully They...

Страница 6: ...on if battery is replaced incorrectly or with an incorrect type Replace the battery only with the same or equivalent type recommended by the manufacturer Dispose of used bat teries according to the manufacturer s instructions ...

Страница 7: ...ct 25 3 3 Installing the CPU and Heat Sink 26 3 4 Installing the Memory 28 3 4 1 Eight Channel Memory Configuration 28 3 4 2 Installing a Memory 29 3 4 3 Processor and Memory Module Matrix Table 29 3 4 4 Memory Population Table 30 3 5 Installing the PCI Expansion Card 31 3 6 Installing the Hard Disk Drive 32 3 7 Replacing the Fan Assembly 33 3 8 Replacing the Power Supply 34 3 9 Cable Routing 35 C...

Страница 8: ...Configuration 82 5 2 20 MAC IPv6 Network Configuration 83 5 3 AMD CBS Menu 84 5 3 1 CPU Common Options 85 5 3 2 DF Common Options 90 5 3 3 UMC Common Options 95 5 3 4 NBIO Common Options 109 5 3 5 FCH Common Options 115 5 3 6 NTB Common Options 119 5 3 7 SOC Miscellaneous Control 120 5 3 8 Workload Tuning 121 5 4 AMD PBS Menu 122 5 4 1 RAS 123 5 5 Chipset Setup Menu 125 5 5 1 North Bridge 126 5 5 ...

Страница 9: ... 9 5 9 Save Exit Menu 141 5 10 BIOS POST Beep code AMI standard 142 5 10 1 PEI Beep Codes 142 5 10 2 DXE Beep Codes 142 ...

Страница 10: ... 10 This page intentionally left blank ...

Страница 11: ...s dry and first touch a metal object to eliminate static electricity Prior to installing the motherboard please have it on top of an antistatic pad or within an electrostatic shielding container Before unplugging the power supply cable from the motherboard make sure the power supply has been turned off Before turning on the power make sure the power supply voltage has been set according to the loc...

Страница 12: ...B supported Memory speed Up to 3200 2933 MHz Note Follow BIOS setting and memory QVL list if running 3200 Mhz with 2DPC Socket ocket LAN 2 x SFP 10Gb s LAN ports Broadcom BCM 57810S 1 x 10 100 1000 management LAN Socket Socket Video Integrated in Aspeed AST2500 2D Video Graphic Adapter with PCIe bus interface 1920x1200 60Hz 32bpp Socket Socket Storage Total 16 x 2 5 SATA SAS hot swappable HDD SSD ...

Страница 13: ...ull height half length Riser Card CRSG018 Slot_3 1 x PCIe x16 slots Gen3 x16 Low profile half length 1 x M 2 slot M key PCIe Gen3 x4 Supports NGFF 2242 2260 2280 cards Socket Socket Internal I O 1 x 24 pin ATX main power connector 2 x 8 pin ATX 12V power connectors 4 x SlimSAS connectors 1 x M 2 slot 2 x CPU fan headers 5 x System fan headers 1 x USB 3 0 header 1 x USB 2 0 header 1 x COM_2 header ...

Страница 14: ...ocket Socket Backplane I O Backplane P N 9CBP20O1NR 00 Speed and bandwidth SAS 12Gb s SATA 6Gb s Socket Socket TPM 1 x TPM header with LPC interface Optional TPM2 0 kit CTM000 Socket Socket Power Supply 2 x 1200W redundant PSUs 80 PLUS Platinum ACInput 100 240V 12 7A 50 60Hz 220 240V 16A DC Input 240Vdc 6A DC Output Max 1000W 100 240V 12V 80 5A 12Vsb 3A Max 1200W 200 240V or 240Vdc input 12V 97A 1...

Страница 15: ...le System Firewall Power Consumption Power Control LDAP AD RADIUS Support Backup Restore Configuration Remote BIOS BMC CPLD Update Event Log Filter User Management Media Redirection Settings PAM Order Settings SSL Settings SMTP Settings Socket Socket Environment Ambient Temperature Relative Humidity Operating temperature 10 C to 35 C Non operating temperature 40 C to 60 C Operating humidity 8 80 n...

Страница 16: ...Hardware Installation 16 1 3 System Block Diagram ...

Страница 17: ... and Buttons for detail description of function LEDs 2 2 Rear View No Description 1 Serial Port 2 VGA Port 3 SFP 10G LAN Port 2 4 SFP 10G LAN Port 1 5 USB 3 0 Port x 2 6 Server Management LAN Port 7 USB 2 0 Port x 2 8 ID Button with LED HDD0 HDD1 HDD2 HDD3 HDD4 HDD5 HDD6 HDD7 HDD12 HDD13 HDD14 HDD15 HDD16 HDD17 HDD18 HDD19 1 1 2 3 4 5 6 7 8 PSU1 PSU2 ...

Страница 18: ...D Button Blue On System identification is active N A Off System identification is disabled 3 4 LAN 1 2 Active Link LEDs Green On Indicates a link between the system and the network or no access Green Blink Indicates data trasmission or receiving is occuring N A Off Indicates no data transmission or receiving is occuring 5 Green On Indicates locating the HDD Blink Indicates accessing the HDD Amber ...

Страница 19: ...stem fan failure System temperature issue Blink Indicates non critical condition may include Redundant power module failure Temperature and voltage issue Chassis intrusion N A Off System is not powered on or in ACPI S5 state power off System is in ACPI S4 state hibernate mode 7 Reset Button Press this button to reset the system ...

Страница 20: ... data transmission or receiving is occurring 2 10GbE Speed LED Green On 10Gbps data rate Yellow On 5Gbps 2 5Gbps 1Gbps data rate N A Off 100 Mbps data rate 3 1GbE Speed LED Yellow On 1Gbps data rate Green On 100 Mbps data rate N A Off 10 Mbps data rate 4 1GbE Link Activity LED Green On Link between system and network or no access Blink Data transmission or receiving is occurring N A Off No data tr...

Страница 21: ...Hz Green Blinking Power supply firmware updating mode Amber AC cord unplugged or AC power lost with a second power supply in parallel still with AC input power Power supply critical event causing shut down failure OCP OVP fan failure and UVP 1Hz Amber Blinking Power supply warning events where the power supply continues to operate high temp high power high current and slow fan ...

Страница 22: ...Back Panel Removed HDD Slot LED on Back Panel Disk LED Removed HDD Slot RAID SKU No RAID configuration via HBA RAID configuration via HW RAID Card or SW RAID Card HDD Access HDD Present No Access BLINK 2 BLINK 2 OFF OFF OFF OFF OFF OFF Low Speed 2 Hz 3 3 Rebuilding HDD Fault OFF OFF ON OFF ON OFF OFF OFF Locate Amber Green ON 1 ON OFF ON 1 OFF Green Amber Green ON 1 Green OFF Amber Amber OFF LED1 ...

Страница 23: ...u are working inside the computer case If possible wear a grounded wrist strap when you are working inside the computer case Alternatively discharge any static electricity by touching the bare metal system of the computer case or the bare metal body of any other grounded appliance Hold electronic circuit boards by the edges only Do not touch the components on the board unless it is necessary to do...

Страница 24: ...ve the seven screws on the back system cover 1 Remove the five screws on the front top cover 2 Slide the cover to the rear of the system and then remove the cover in the direction indicated by the arrow 3 Lift up and remove the back system cover 4 Slide the cover to the rear of the system and then remove the front cover in the direction indicated by the arrow 5 To reinstall the chassis cover rever...

Страница 25: ...ctions to remove install the fan duct 1 Remove the screw securing the CPU fan duct 2 Lift up to remove the CPU fan duct 3 Then lift up to remove the GPU fan duct 4 To install the fan duct align the fan duct with the guiding groove Push down the fan duct into chassis until its firmly seats 2 3 1 ...

Страница 26: ...w these instructions to install the CPU 1 Align and install the processor on the carrier making sure to line up the triangle markers on the corner of the CPU to the triangle mark on the corner of the CPU carrier 2 Slide the carrier assembly into the channels of the carrier bracket 3 Close the carrier bracket so that it firmly latches on to the CPU socket 4 Close the CPU socket cover 5 Tighten and ...

Страница 27: ... Installation CPU 4 5 6 1 3 2 7 2 3 1 4 8 9 When installing the heat sink over the CPU use T30 Lobe driver to tighten the 4 captive nuts in sequential order 1g2g3g4 The screw tightening torque 8 0 5kgf cm 17 0 1 0 lbf in ...

Страница 28: ..._P0_A1 DIMM_P0_B0 DIMM_P0_B1 DIMM_P0_C0 DIMM_P0_C1 DIMM_P0_E1 DIMM_P0_E0 DIMM_P0_H1 DIMM_P0_H0 DIMM_P0_G1 DIMM_P0_G0 DIMM_P0_F1 DIMM_P0_F0 Read the following guidelines before you begin to install the memory Make sure that the motherboard supports the memory It is recommended that memory of the same capacity brand speed and chips be used Always turn off the computer and unplug the power cord from ...

Страница 29: ...y Follow these instructions to install the Memory 1 Insert the DIMM memory module vertically into the DIMM slot and push it down 2 Close the plastic clip at both edges of the DIMM slots to lock the DIMM module 3 Reverse the installation steps when you want to remove the DIMM module 1 2 2 3 4 3 Processor and Memory Module Matrix Table Processor and Memory Module Matrix Table 1 DIMM CPU CPU0 2 DIMMs...

Страница 30: ...0 LRDIMM 4DR 4 Ranks 3200 2S2R 4 Ranks 3200 2S4R 8 Ranks 3200 EPYC Memory Speed based on DIMM Population One DIMM per Channel EPYC Memory Speed based on DIMM Population Two DIMM per Channel DIMM Type DIMM Population Max EPYC 7003 DDR Frequency MHz DIMM 0 DIMM 1 RDIMM 1R 3200 1R 1R 2933 2R or 2DR 3200 1R 2R or 2DR 2933 2R or 2DR 2R or 2DR 2933 LRDIMM 4DR 3200 4DR 4DR 2933 2S2R 4 Ranks 3200 2S4R 8 R...

Страница 31: ... assembly does not include a riser card or any cabling as standard To install a PCI card a riser card must be installed Follow these instructions to install a PCIe card 1 Remove the screws securing the riser bracket 2 Lift up the riser bracket out of system 3 Remove the screw securing the slot cover from riser bracket 4 Orient the PCIe card with the riser guide slot and push in the direction of th...

Страница 32: ...rted incorrectly Make sure that the HDD is connected to the HDD connector on the backplane Follow these instructions to install a 2 5 hard disk drive 1 Press the release button 2 Extend the locking lever 3 Pull the locking lever to remove the HDD tray 4 Align the hard disk drive with the positioning stub on the HDD tray 5 Slide hard disk drive into the blank HDD tray 6 Reinsert the HDD tray into t...

Страница 33: ...rdware Installation Follow these instructions to replace a fan assembly 1 Lift up the fan assembly from the chassis 2 Reverse the previous steps to install the replacement fan assembly 3 7 Replacing the Fan Assembly ...

Страница 34: ... the left side of the power supply unit along the direction of the arrow 2 Pull the power supply handle at the same time and pull out the power supply unit 3 Insert the replacement power supply unit firmly into the chassis Connect the AC power cord to the replacement power supply 4 Repeat steps 1 3 for replacement of the second power supply 2 1 3 ...

Страница 35: ... 35 System Hardware Installation Front Switch Cable Front LED Cable PMBus Cable 3 9 Cable Routing ...

Страница 36: ...System Hardware Installation 36 HDD Back Plane Board Power Cable HDD Back Plane Board Signal Cable ...

Страница 37: ... 37 System Hardware Installation System Main Power Cable System to Motherboard Power Cable ...

Страница 38: ...System Hardware Installation 38 SlimLine SAS to HDD Back Plane Board Cable 1 SlimLine SAS to HDD Back Plane Board Cable 2 ...

Страница 39: ... 39 System Hardware Installation SlimLine SAS to HDD Back Plane Board Cable 1 SlimLine SAS to HDD Back Plane Board Cable 2 ...

Страница 40: ...System Hardware Installation 40 GPU Power Cable Fan Duct GPU Power 1 GPU Power 2 ...

Страница 41: ... Item Description 1 2 x 12 pin main power connector 2 PMBus connector 3 BMC firmware readiness LED 4 TPM connector 5 2 x 4 pin power connector for memory 6 2 x 4 pin power connector for CPU 7 Slimline connector 0 SATA 6Gb s signal 8 Slimline connector 1 SATA 6Gb s signal 9 Slimline connector 2 SATA 6Gb s signal 10 Slimline connector 3 SATA 6Gb s signal ...

Страница 42: ...13 M 2 slot Gen3 x4 14 USB 3 0 header 15 USB 2 0 header 16 Serial port cable connector 17 PCIe x16 slot Gen3 x16 18 PCIe x8 slot Gen3 x8 19 PCIe x16 slot Gen3 x16 20 PCIe x16 slot Gen3 x16 21 PCIe x16 slot Gen3 x8 22 PCIe x16 slot Gen3 x16 23 PCIe x8 slot Gen3 x8 24 Battery socket ...

Страница 43: ...Closed From core chipset 2 3 Closed From BMC default setting 3 S3 Power On Select Jumper 1 2 Closed Stop an initial power on when BMC is not ready 2 3 Closed Keep initial power on default setting 4 Clearing Supervisor Password Jumper 1 2 Closed Normal operation default setting 2 3 Closed Skip supervisor password 5 BIOS Recovery Jumper 1 2 Closed Normal operation default setting 2 3 Closed BIOS rec...

Страница 44: ...Motherboard Components 44 This page intentionally left blank ...

Страница 45: ... with caution Inadequate BIOS flashing may result in system malfunction It is recommended that you not alter the default settings unless you need to to prevent system instability or other unexpected results Inadequately altering the settings may result in system s failure to boot If this occurs try to clear the CMOS values and reset the board to default values Refer to the Exit section in this cha...

Страница 46: ...f the North Bridge Server Management Server additional features enabled disabled setup menus Security Change set or disable supervisor and user password Configuration supervisor password allows you to restrict access to the system and BIOS Setup A supervisor password allows you to make changes in BIOS Setup A user password only allows you to view the BIOS settings but not to make changes Boot This...

Страница 47: ... displayed on the bottom line of the Main Menu Submenu Help While in a submenu press F1 to display a help screen General Help of function keys available for the menu Press Esc to exit the help screen Help for each item is in the Item Help block on the right side of the submenu When the system is not stable as usual select the Restore Defaults item to set your system to its defaults The BIOS Setup ...

Страница 48: ...e of the installed memory Memory Frequency Note3 Displays the frequency information of the installed memory VR Information Version Displays VR version information AGESA PI Version PI Version Displays AGESA PI version information Onboard LAN Information LAN1 MAC Address Note1 Displays LAN MAC address information LAN2 MAC Address Note2 Displays LAN MAC address information System Date Sets the date f...

Страница 49: ... Menu The Advanced Menu displays submenu options for configuring the function of various hardware components Select a submenu item then press Enter to access the related submenu screen When Boot Mode Select is set to UEFI Default ...

Страница 50: ...BIOS Setup 50 When Boot Mode Select is set to Legacy in the Boot Boot Mode Select section ...

Страница 51: ... Description Configuration Security Device Support Enable Disable BIOS support for security device OS will not show security device TCG EFI protocol and INT1A interface will not be available Options available Enable Disable Default setting is Enable ...

Страница 52: ...BIOS Setup 52 5 2 2 PSP Firmware Versions The PSP Firmware Versions page displays the basic PSP firmware version information Items on this window are non configurable ...

Страница 53: ...OnBrd Ext VGA Select Note Selects between onboard or external VGA support Options available Auto Onboard External Default setting is Onboard Note This configurable option will be displayed when Boot Mode Select is set to Legacy in the Boot Boot Mode Select section ...

Страница 54: ... 2 4 AST2500 Super IO Configuration Parameter Description AST2500 Super IO Configuration Super IO Chip Displays the super IO chip information Serial Port 1 Configuration Press Enter for configuration of advanced items ...

Страница 55: ...rt Note1 Enable Disable the Serial Port COM When set to Enabled allows you to configure the Serial port 1 2 settings When set to Disabled displays no configuration for the serial port Options available Enabled Disabled Default setting is Enabled Devices Settings Note2 Displays the Serial Port 1 2 device settings ...

Страница 56: ... IO 3F8h IRQ 4 IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5 6 7 9 10 11 12 IO 3E8h IRQ 3 4 5 6 7 9 10 11 12 IO 2E8h IRQ 3 4 5 6 7 9 10 11 12 Default setting is Auto Options available for Serial Port 2 Auto IO 2F8h IRQ 3 IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5 6 7 9 10 11 12 IO 3E8h IRQ 3 4 5 6 7 9 10 11 12 IO 2E8h IRQ 3 4 5 6 7 9 10 11 12 Default setting is Auto Please note that t...

Страница 57: ...tion Wake System from S5 Note1 Enable Disable system wake on alarm event Options available Disabled Fixed Time When Fixed Time enabled system will wake on the hr min sec specified Default setting is Disabled Note1 Advanced items prompt when this item is defined ...

Страница 58: ...r LAN Console Redirection Settings Press Enter to configure advanced items Please note that this item is configurable when COM1 Serial Over LAN COM2 Console Redirection is set to Enabled Terminal Type Selects a terminal type to be used for console redirection Options available VT100 VT100 ANSI VT UTF8 Default setting is ANSI Bits per second Selects the transfer rate for console redirection Options...

Страница 59: ... 2 Default setting is 1 Flow Control Flow control can prevent data loss from buffer overflow When sending data if the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty a start signal can be sent to re start the flow Hardware flow control uses two wires to send start stop signals Options available None Hardware RTS CTS Default setting is None VT U...

Страница 60: ...MS Console Redirection Note EMS console redirection allows the user to configure Console Redirection Settings to support Out of Band Serial Port management Options available Enabled Disabled Default setting is Disabled Serial Port for Out of Band EMS Console Redirection Settings Press Enter to configure advanced items Please note that this item is configurable when Serial Port for Out of Band Mana...

Страница 61: ...ta loss from buffer overflow When sending data if the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty a start signal can be sent to re start the flow Hardware flow control uses two wires to send start stop signals Options available None Hardware RTS CTS Software Xon Xoff Default setting is None ...

Страница 62: ...7 CPU Configuration Parameter Description SVM Mode Enable Disable the CPU Virtualization Options available Enabled Disabled Default setting is Enabled CPU 0 Information Press Enter to view more information related to CPU ...

Страница 63: ... 45 BIOS Setup 5 2 8 PCI Subsystem Settings ...

Страница 64: ...oller Note2 Enable Disable the onboard LAN devices Options available Enabled Disabled Default setting is Enabled Onboard LAN I O ROM Note2 Enable Disable the onboard LAN devices and initializes device expansion ROM Options available Enabled Disabled Default setting is Enabled PCI Devices Common Settings Above 4G Decoding Enable Disable memory mapped I O to 4GB or greater address space Above 4G Dec...

Страница 65: ...ble Auto Enabled Disabled Default setting is Enabled XHCI Hand off Enable Disable the XHCI USB 3 0 Hand off support Options available Enabled Disabled Default setting is Enabled USB Mass Storage Driver Support Note Enable Disable the USB Mass Storage Driver Support Options available Enabled Disabled Default setting is Enabled USB hardware delays and time outs USB transfer time out The time out val...

Страница 66: ...or a Root port it is 100 ms for a Hub port the delay is taken from Hub descriptor Options available Auto Manual Default setting is Auto Mass Storage Devices AMI Virtual CDROM0 1 00 AMI HDisk0 1 00 Generic Flash Disk 8 07 ADATA USB Flash Drive 1100 Mass storage device emulation type AUTO enumerates devices according to their media format Optical drives are emulated as CDROM drives with no media wil...

Страница 67: ...ions available Enabled Disabled Default setting is Disabled Ipv6 PXE Support Enable Disable the Ipv6 PXE feature Options available Enabled Disabled Default setting is Enabled Ipv6 HTTP Support Enable Disable the Ipv6 HTTP feature Options available Enabled Disabled Default setting is Disabled PXE boot wait time Wait time in seconds to press ESC key to abort the PXE boot Press the keys to increase o...

Страница 68: ...BIOS Setup 68 5 2 11 NVMe Configuration Parameter Description NVMe Configuration Displays the NVMe devices connected to the system ...

Страница 69: ... 45 BIOS Setup 5 2 12 SATA Configuration Parameter Description SATA Configuration Displays the installed HDD devices information System will automatically detect HDD type ...

Страница 70: ...nfiguration Output Device Type Select output device Options available First loaded Device Onboard Device External Device Specific Device Default setting is Onboard Device OS graphics output Select output device Options available Controlled by OS Onboard VGA Default setting is Control by OS ...

Страница 71: ... 45 BIOS Setup 5 2 14 AMD Mem Configuration Status Parameter Description CPU0 Press Enter to view the memory configuration status related to CPU 0 ...

Страница 72: ...iguration of advanced items Enroll Cert Press Enter to enroll a certificate Enroll Cert Using File Cert GUID Input digit character in 1111111 2222 3333 4444 1234567890ab format Commit Changes and Exit Discard Changes and Exit Delete Cert Client Cert Configuration Press Enter for configuration of advanced items ...

Страница 73: ...Name Press Enter and name iSCSI Initiator Only IQN format is accecpted Range from 4 to 223 Add Attempt Press Enter for configuration of advanced items Delete Attempt Press Enter for configuration of advanced items Change Attempt Order Press Enter for configuration of advanced items ...

Страница 74: ...BIOS Setup 74 5 2 17 QLogic 577xx 578xx 10 Gb Ethernet ...

Страница 75: ...ooted in order for changes to take effect Options available SF SR IOV Default setting is SF Blink LEDs Identifies the physical network port by blinking the associated LED Press the numeric keys to adjust desired values Chip Type Displays the technical specifications for the Network Interface Controller PCI Device ID Displays the technical specifications for the Network Interface Controller Bus Dev...

Страница 76: ...BIOS Setup 76 5 2 17 1 Firmware Image Menu ...

Страница 77: ...nabled Number of VFs per PF Press Enter to configure device and port specific parameters Max PF MSI X Vectors Displays the maximum number of PF MSI X Vectors 0 to 64 UEFI Boot Mode Specifies Driver Boot Mode in UEFI environment Default setting is UNDI MFW Crash Dump Feature Enables MFW bootcode to collect critical device and system information during unanticipated system crash Options available En...

Страница 78: ...o Detect BBS Int 18h Int 19h Default setting is Auto Detect Hide Setup Prompt Configures whether Setup Prompt is displayed during ROM initialization Options available Enabled Disabled Default setting is Disabled Setup Key Stroke Configure key strokes to invoke configuration menu Options available Ctrl S Ctrl B Default setting is Ctrl S Banner Message Timeout Selects the timeout value 0 defaults to...

Страница 79: ...vailable Enabled Disabled Default setting is Disabled VLAN ID 1 4094 Displays the virtual LAN ID 1 to 4094 Boot Retry Count Selects the number of boot retries Options available No Retry 1 Retry 2 Retries 3 Retries 4 Retries 5 Retries 6 Retries Indefinite Retries Default setting is No Retry ...

Страница 80: ...ration of advanced items iSCSI Initiator Parameters Press Enter for configuration of advanced items iSCSI First Target Parameters Press Enter for configuration of advanced items iSCSI Second Target Parameters Press Enter for configuration of advanced items Change Attempt Order Press Enter for configuration of advanced items ...

Страница 81: ...ng VLAN Press the keys to increase or decrease the desired values The valid range is from 0 to 4094 Priority Sets 802 1Q Priority for a new VLAN or an existing VLAN Press the keys to increase or decrease the desired values The valid range is from 0 to 7 Add VLAN Press Enter to create a new VLAN or update an existing VLAN Configured VLAN List Remove VLAN Press Enter to remove an existing VLAN ...

Страница 82: ...Note Options available Enabled Disabled Default setting is Enabled Local IP Address Note Press Enter to configure local IP address Local NetMask Note Press Enter to configure local NetMask Local Gateway Note Press Enter to configure local Gateway Local DNS Servers Note Press Enter to configure local DNS servers Save Changes and Exit Press Enter to save all configurations Note This item appears whe...

Страница 83: ... for the device The string is colon separated e g ff dd 88 66 cc 1 2 3 DAD Transmit Count The number of consective Neighbor solicitation messages sent while performing Duplicate Address Detection on a tentative address A value of zero indicates that Duplicate Address Detection is not performed Policy Options available automatic manual Default setting is automatic Save Changes and Exit Press Enter ...

Страница 84: ... 84 5 3 AMD CBS Menu AMD CBS menu displays submenu options for configuring the CPU related information that the BIOS automatically sets Select a submenu item then press Enter to access the related submenu screen ...

Страница 85: ...EH cloak individual banks and mask deferred error interrupts from each bank Options available Auto Enabled Disabled Default setting is Auto Core Performance Boost Enable Disable the Core Performance Boost function Options available Auto Disabled Default setting is Auto Global C State Control Controls the IO based C state generation and DF C states Options available Auto Enabled Disabled Default se...

Страница 86: ...tions available Auto Enabled Disabled Default setting is Auto SNP Memory RMP Table Coverage Enabled Enter system memory is covered Options available Auto Enabled Disabled Custom Default setting is Auto SMEE Control secure memory encryption enable Options available Auto Enabled Disabled Default setting is Auto Action on BIST Failure Action to take when a CCD BIST failure is detected Options availab...

Страница 87: ...cept or decline enabling CCDs processor cores and threads When accepted you can control the number of CCDs to be used the number of cores to be used and whether to enable or disable Simultaneous Multithreading Technology SMT support SMT Control Can be used to disable symmetric multithreading To re enable SMT a POwer CYCLE is needed after select the Enable option Select Auto base on BIOS PCD PcdAmd...

Страница 88: ...le Disable Default setting is Auto L1 Region Prefetcher Use memory access history to fetch additional lines when the data access for a given instruction tends to be followed by other data accesses Options available Auto Enable Disable Default setting is Enable L2 Stream HW Prefetcher Enable Disable L2 Stream HW Prefetcher Options available Auto Enable Disabled Default setting is Enable L2 Up Down ...

Страница 89: ... 45 BIOS Setup 5 3 1 3 Core Watchdog Parameter Description Core Watchdog Core Watchdog Timer Enable Enable Disable CPU Watchdog Timer Options available Auto Enabled Disabled Default setting is Auto ...

Страница 90: ...Disable DF Sync Flood propagation Options available Auto Sync flood disabled Sync flood enabled Default setting is Auto Frezze DF module queues on error Options available Auto Enabled Disabled Default setting is Auto CC6 memory region encryption Controls whether or not the CC6 save restor memory is encrypted Options available Auto Enabled Disabled Default setting is Auto System probe filter Enable...

Страница 91: ...efault setting is Auto Poison scrubber control Enable Disable the Poison scrubber control feature Options available Auto Enabled Disabled Default setting is Auto Redirect scrubber control Enable Disable the Redirect scrubber control feature Options available Auto Enabled Disabled Default setting is Auto Redirect scrubber limit Sets the redirect scrubber limit Options available Auto 2 4 8 Infinite ...

Страница 92: ... remap Enable Disable to remap DRAM out of the space just below the 1TB boundary The ability to remap depends on DRAM configuration NPS and interleaving selection and may not always be possible Options available Auto Do not remap Attempt to remap Default setting is Auto DRAM map inversion Enable Disable the DRAM map inversion function Options available Auto Enabled Disabled Default setting is Auto...

Страница 93: ...Options available Auto Enabled Disabled Default setting is Auto ACPI SLIT Distance Control Determines how the SLIT distances are declared Options available Auto Manual Default setting is Auto ACPI SLIT remote relative distance Sets the remote socket distance for 2P systems as near 2 8 or far 3 2 Options available Auto Near Far Default setting is Auto ...

Страница 94: ...ault setting is Auto 4 link xGMI max speed Specifies the max speed of 4 link xGMI Options available Auto 10 667Gbps 13Gbps 16Gbps 18Gbps Default setting is 10 667Gbps 3 link xGMI max speed Specifies the max speed of 3 link xGMI Options available Auto 10 667Gbps 13Gbps 16Gbps 18Gbps Default setting is 10 667Gbps xGMI TXEQ Mode Configures xGMI TXEQ RX vetting Mode Options available Auto TXEQ_Disable...

Страница 95: ... Common Options DDR4 Common Options Press Enter for configuration of advanced items DRAM Memory Mapping Press Enter for configuration of advanced items NVDIMM Press Enter for configuration of advanced items Memory MBIST Press Enter for configuration of advanced items ...

Страница 96: ...nel at 3200MHz function select Accept at warning message change Overclock from Auto to Enabled and then set memory speed to 3200MHz DRAM Controller Configuration Press Enter to configure DRAM Controller Configuration CAD Bus Configuration Press Enter to configure CAD Bus Configuration Data Bus Configuration Press Enter to configure Data Bus Configuration Common RAS Press Enter to configure Common ...

Страница 97: ...und UrgRefLimit DRAM Maximum Activate Count Options available Auto Unlimited MC 200K 300K 400K 500K 600K 700K Default setting is Auto DRAM Refresh Rate Options available 7 8 usec 3 9 usec Default setting is 7 8 usec Self Refresh Exit Staggering Options available Disabled Trfc 3 Trfc 4 Default setting is Disabled Cmd2T Selects the Cmd2T mode on ADDR CMD Options available Auto 1T 2T Default setting ...

Страница 98: ...guration CAD Bus Timing User Controls Setup time on CAD bus signals to Auto or Manual Options available Auto Manual Default setting is Auto CAD Bus Drive Strength User Controls Drive Strength on CAD bus signals to Auto or Manual Options available Auto Manual Default setting is Auto ...

Страница 99: ...3 1 3 Data Bus Configuration Parameter Description Data Bus Configuration Data Bus Configuration User Controls Specifies the mode for drive strength to Auto or Manual Options available Auto Manual Default setting is Auto ...

Страница 100: ...tion Options available Auto Enabled Disabled Default setting is Auto Max Parity Error Replay Configures the Max Parity Error Replay 0 0x3f Default setting is 8 Please note that this item is configurable when DRAM Address Command Parity Retry is set to Enabled Write CRC Enable Enable Disable the Write CRC function Options available Auto Enabled Disabled Default setting is Auto DRAM Write CRC Enable...

Страница 101: ...tems DRAM ECC Symbol Size Configures the DRAM ECC Symbol Size Options available Auto x4 x8 x16 Default setting is Auto DRAM ECC Enable Enable Disable DRAM ECC When set to Auto it will set ECC to enable Options available Auto Enabled Disabled Default setting is Auto DRAM UECC Retry Enable Disable DRAM UECC Retry Options available Auto Enabled Disabled Default setting is Auto ...

Страница 102: ...rameter Description Security TSME Enable Disable Transparent SME Options available Auto Enabled Disabled Default setting is Auto Data Scramble Enable Disable Data Scrambling Options available Auto Enabled Disabled Default setting is Auto ...

Страница 103: ...MU Training Press Enter to configure PMU Training DFE Traing Enable Disable DDR power down mode Options available Auto Enabled Disabled Default setting is Auto FFE Write Training Auto Enabled Disabled Default setting is Auto PMU Pattern Bits Controls Auto Manual Default setting is Auto ...

Страница 104: ... No help string Options available Auto Enabled Disabled Default setting is Auto BankGroupSwapAlt Configures the BankGroupSwapAlt Options available Auto Enabled Disabled Default setting is Auto Address Hash Bank Enable Disable bank address hashing Options available Auto Enabled Disabled Default setting is Auto Address Hash CS Enable Disable CS address hashing Options available Auto Enabled Disabled...

Страница 105: ... 45 BIOS Setup 5 3 3 3 NVDIMM Parameter Description NVDIMM Disable NVDIMM N feature for memory margin tool Options available No Yes Default setting is No ...

Страница 106: ...e Mode Data Eye Mode Default setting is Auto MBIST Aggressors Note Enable Disable MBIST Aggressor test Options available Auto Enabled Disabled Default setting is Auto MBIST Per Bit Slave Die Reporting Note Enable Disable to report 2D data eye results in ABL log for each DQ Chipselect and Channel Options available Auto Enabled Disabled Default setting is Auto Data Eye Press Enter to configure advan...

Страница 107: ...ol function Options available Enabled Disabled Default setting is Disabled Aggressor Static Lane Select Upper 32 bits This item is configurable when Aggressor Static Lane Control is set to Enabled Aggressor Static Lane Select Lower 32 bits This item is configurable when Aggressor Static Lane Control is set to Enabled Aggressor Static Lane Select ECC This item is configurable when Aggressor Static ...

Страница 108: ...Voltage Sweep 1D Timing Sweep 2D Full Data Eye Worst Case Margin Only Default setting is Worst Case Margin Only Worst Case Margin Granularity Configures Worst Case Margin Granularity Options available Per Chip Select Per Nibble Default setting is Worst Case Margin Only Read Voltage Sweep Step Size Configures the step size for read Data Eye voltage sweep Options available 1 2 4 Default setting is 2...

Страница 109: ...numeration ARI Forwarding Enable for each downstream port Options available Auto Enabled Disabled Default setting is Auto PCIe Ten Bit Tag Support Enable Disable PCIe ten bit tags for supported devices Auto Disabled Options available Auto Enabled Disabled Default setting is Auto SMU Common Options Press Enter for configuration of advanced items NBIO RAS Common Options Press Enter for configuration...

Страница 110: ...available Auto Manual Default setting is Auto Loopback Mode Enabled Disabled PCIe Loopback mode Options available Auto Enabled Disabled Default setting is Auto CV test Set this to Enabled to support running PCIECV tool Auto preserve hardware defaults Options available Auto Enabled Disabled Default setting is Auto CAC Weight Adjustment EDC Mode select Options available Auto Enabled Disabled Default...

Страница 111: ...Control Selects use the fused TDP or set customized TDP TDP is used to define the RC thermal model only Options available Auto Manual Default setting is Auto cTDP Display cTDP information EfficiencyModeEn Options available Auto Enabled Default setting is Auto Package Power Limit Control Selects use the fused PPT or set customized PPT PPT will be used as the ASIC power limit Options available Auto ...

Страница 112: ...isable Options available Auto Enabled Disabled Default setting is Auto DLMM Support Select DLMM support enable or disable Options available Auto Enabled Disabled Default setting is Auto BoostFmaxEn Options available Auto Enabled Default setting is Auto EDC Current Options available Enable Disable Default setting is Disable LCLK Frequency Control Press Enter for advanced configuration DF PSTATE Mod...

Страница 113: ...bit of 0 indicates LOW serverity NBIO SyncFlood Generation The value may be used to mask SyncFlood caused by NBIO RAS options Options available Auto Enabled Disabled Default setting is Auto NBIO SyncFlood Reporting The value may be used to enanle SyncFlood reporting to APML Options available Enabled Disabled Default setting is Disabled Egress Poison Mask High Enables mask for masking of errors log...

Страница 114: ...Default setting is Disabled SLINK Read Response Error Handling Options available Enabled Trigger MCOMMIT Error Log Errors in MCA Default setting is Log Errors in MCA Log Poison Data from SLINK Enable Disable the Log Poison Data from SLINK feature Options available Enabled Disabled Default setting is Disabled PCIe Aer Reporting Mechanism Selects the method of reporting AER errors from PCI Express O...

Страница 115: ...arameter Description FCH Common Options AC Power Loss Options Press Enter for configuration of advanced items FCH RAS Options Press Enter for configuration of advanced items Miscellaneous Options Press Enter for configuration of advanced items ...

Страница 116: ...tup 116 5 3 5 1 AC Power Loss Options Parameter Description AC Power Loss Options AC Loss Control Selects the AC Loss Control Method Options available Power Off Power On Last State Default setting is Power off ...

Страница 117: ...ALink RAS Support Enable Disable the ALink RAS Support Options available Auto Enabled Disabled Default setting is Auto Reset after sync flood Enables AB to forward downstream sync flood message to system controller Options available Auto Enabled Disabled Default setting is Auto ...

Страница 118: ...BIOS Setup 118 5 3 5 3 Miscellaneous Options Parameter Description Miscellaneous Options Boot Time Enable Options available Auto Enabled Disabled Default setting is Auto ...

Страница 119: ...NTB Enable Options available Auto Enable Default setting is Auto Socket 0 P1 NTB Enable Options available Auto Enable Default setting is Auto Socket 0 P2 NTB Enable Options available Auto Enable Default setting is Auto Socket 0 P3 NTB Enable Options available Auto Enable Default setting is Auto ...

Страница 120: ...nable Disable the ConsoleOut function for ABL Options available Auto Enabled Disabled Default setting is Auto ABL PMU message Control Note To Control the total number of PMU debug messages Options available Auto Enabled Disabled Default setting is Auto Note This item appears when ABL Console Out Control is set to Enabled ...

Страница 121: ...ter Description Workload Tuning Workload Profile Select the profile for different workloads Default setting is Auto Performance Tracing Enable to allow capturing performance traces Options available Auto Enabled Disabled Default setting is Auto ...

Страница 122: ...king for protect ROM part Options available Enabled Disabled Default setting is Disabled iLA TraceMemoryEn Reserved 1M bytes MMIO space on 1M boundary when iLA TraceMemoryEn disabled Options available Enabled Disabled Default setting is Disabled iLA TraceMemoryEn reserved MMIO Reserved function SRIS mode debug Control SRIS mode debug Options available Auto Enabled Disabled Default setting is Auto ...

Страница 123: ...Period GHES Notify Type Selects the Notification type for deferred corrected errors Options available Polled SCI Default setting is Polled GHES UnCorr Notify Type Selects the Notification type for uncorrected errors Options available Polled NMI Default setting is NMI PCIe GHES Notify Type Selects the Notification type for PCIe corrected errors Options available Polled SCI Default setting is Polled...

Страница 124: ...RR Notify Type Selects the Notification type for CCIX deffered error Options available Polled SCI Default setting is Polled CCIX GHES Corrected Err Notify Type Selects the Notification type for CCIX corrected error Options available Polled SCI Default setting is Polled DDR4 DRAM Hard Post Package Repair This feature allows spare DRAM rows to replace malfunctioning rows via an in field repair mecha...

Страница 125: ...er to access the related submenu screen Parameter Description PCIe Compliance Mode Options available On Off Default setting is Off Program All VR Enable Disable program all VR on MB Options available Enabled Disabled Default setting is Enabled North Bridge Press Enter for configuration of advanced items Fabric Resource Press Enter for configuration of advanced items ...

Страница 126: ...er Description North Bridge Configuration Memory Information Total Memory Displays the total memory information CPU0 Information Press Enter to view information related to CPU 0 CPU1 Information Press Enter to view information related to CPU 1 ...

Страница 127: ... 45 BIOS Setup 5 5 2 Fabric Resource Parameter Description Fabric Resource Socket NBIO_ PCIe Bus Number Change Socket 0 1 NBIO_ PCIe Bus Number ...

Страница 128: ... Default setting is Do Nothing OS Watchdog Timer Enable Disable OS Watchdog Timer function Options available Enabled Disabled Default setting is Disabled OS Wtd Timer Timeout Configures OS Watchdog Timer Options available 5 minutes 10 minutes 15 minutes 20 minutes Default setting is 10 minutes Please note that this item is configurable when OS Watchdog Timer is set to Enabled OS Wtd Timer Policy C...

Страница 129: ...ed 2 minutes 4 minutes 6 minutes Default setting is 2 minutes System Event Log Press Enter to configure advanced items View FRU Information Press Enter to view the FRU information BMC network configuration Press Enter to configure advanced items IPv6 BMC Network Configuration Press Enter to configure advanced items ...

Страница 130: ...e SEL Choose options for erasing SEL Options available No Yes On next reset Yes On every reset Default setting is No When SEL is Full Choose options for reactions to a full SEL Options available Do Nothing Erase Immediately Default setting is Do Nothing Custom EFI Logging Options Log EFI Status Codes Enable Disable the logging of EFI Status Codes if not already converted to legacy Options availabl...

Страница 131: ...U Information The FRU page is a simple display page for basic system ID information as well as System product information Items on this window are non configurable Note The model name will vary depends on the product you purchased ...

Страница 132: ...g is DynamicBmcDhcp Station IP address Displays IP Address information Subnet mask Displays Subnet Mask information Please note that the IP address must be in three digitals for example 192 168 000 001 Router IP address Displays the Router IP Address information Station MAC address Displays the MAC Address information VLAN Support Set to BMC enabled diisabled VLAN Options available Enabled Disable...

Страница 133: ...work during BIOS phase Options available Unspecified Disable Enable Default setting is Enable IPv6 BMC Lan IP Address Source Selects to configure LAN channel parameters statically or dynamically by BIOS or BMC Options available Unspecified Static Dynamic Obtained by BMC running DHCP Default setting is Enable Dynamic Obtained by BMC running DHCP IPv6 BMC Lan IP Address Prefix Length Check if the IP...

Страница 134: ...ll settings in the Setup Utility User Password Entering this password will restrict a user s access to the Setup menus To enable or disable this field a Administrator Password must first be set A user can only access and modify the System Time System Date and Set User Password fields Parameter Description Administrator Password Press Enter to configure the administrator password User Password Pres...

Страница 135: ...ooting process to be pre signed with valid digital certificates This way the system knows all files being loaded before Windows loads to the login screen have not been tampered with When set to Standard it will automatically load the Secure Boot keys form the BIOS databases When set to Custom you can customize the Secure Boot settings and manually load its keys from the BIOS database Options avail...

Страница 136: ... Key Exchange Keys KEK Displays the current status of the Key Exchange Key Database KEK Press Enter to configure a new KEK or load additional KEK from storage devices Options available Set New Append Authorized Signatures DB Displays the current status of the Authorized Signature Database Press Enter to configure a new DB or load additional DB from storage devices Options available Set New Append ...

Страница 137: ...ber of seconds to wait for setup activation key 65535 0xFFFF means indefinite waiting Press the numeric keys to input the desired values Bootup NumLock State Enable Disable the Bootup NumLock function Options available On Off Default setting is Off Quiet Boot Enable Disable showing the logo during POST Options available Enabled Disabled Default setting is Enabled Boot mode select Selects the boot ...

Страница 138: ...ure the boot priority By default the server searches for boot devices in the following sequence 1 Hard drive 2 CD COM DVD drive 3 USB device 4 Network 5 UEFI UEFI Network Drive BBS Priorities Press Enter to configure the boot priority UEFI Application Boot Priorities Press Enter to configure the boot priority ...

Страница 139: ...rities The UEFI network drive BBS priorities submenu allows you to specify the boot device priority from the available UEFI network drives during system boot up BIOS setup will display an error message if the legacy drive s specified is not bootable ...

Страница 140: ...orities The UEFI application boot priorities submenu allows you to specify the boot device priority from the available UEFI applications during system boot up BIOS setup will display an error message if the legacy drive s specified is not bootable ...

Страница 141: ...ne so far to any of the setup options Options available Yes No Default Options Restore Defaults Loads the default settings for all BIOS setup parameters Setup Defaults are quite demanding in terms of resources consumption If you are using low speed memory chips or other kinds of low performance components and you choose to load these settings the system might not function properly Options availabl...

Страница 142: ...L was not found 3 DXE Core Firmware Volume was not found 4 Recovery failed 4 S3 Resume failed 7 Reset PPI is not available 5 10 2 DXE Beep Codes of Beeps Description 1 Invalid password 4 Some of the Architectural Protocols are not available 5 No Console Output Devices are found 5 No Console Input Devices are found 6 Flash update is failed 7 Reset protocol is not available 8 Platform PCI resource r...

Страница 143: ... 45 BIOS Setup This page intentionally left blank ...

Отзывы: