background image

- 118 -

BIOS Setup

2-7-1  Secure Boot 

The Secure Boot submenu is applicable when your device is installed the Windows

®

 8 (or above) operating 

system.

 

 

(Note)  Advanced items prompt when this item is set to 

Custom

.

Parameter

Description

System Mode

Displays if the system is in User mode or Setup mode.

Secure Boot

Enable/ Disable the Secure Boot function.
Options available: Enabled, Disabled. Default setting is 

Disabled

.

Secure Boot Mode

(Note)

Secure Boot requires all the applications that are running during the 

booting process to be pre-signed with valid digital certificates. This way, 
the system knows all files being loaded before Windows loads to the login 

screen have not been tampered with.
When set to Standard, it will automatically load the Secure Boot keys 
form the BIOS databases.
When set to Custom, you can customize the Secure Boot settings and 
manually load its keys from the BIOS database.
Options available: Standard, Custom. Default setting is 

Standard

.

Restore Factory Keys

Forces the system to user mode and installs factory default Secure Boot
key database.

Enter Audit Mode

Enter Audit Mode workflow.

Содержание MZ72-HB2

Страница 1: ...MZ72 HB2 AMD EPYC 7003 Dual Sockets Server Motherboard User Manual Rev 3 0 ...

Страница 2: ...d BIOS User Guide detailed information about the installation use of an add on hardware or software component e g BMC firmware rail kit compatible with this product Quick Installation Guide a short guide with visual diagrams that you can reference easily for installation purposes of this product e g motherboard server barebones Please see the support section of the online product page to check the...

Страница 3: ...rnal Connectors 18 1 8 Jumper Settings 27 Chapter 2 BIOS Setup 28 2 1 The Main Menu 30 2 2 Advanced Menu 33 2 2 1 Trusted Computing 35 2 2 2 PSP Firmware Versions 36 2 2 3 Legacy Video Select 37 2 2 4 AST2600 Super IO Configuration 38 2 2 5 S5 RTC Wake Settings 40 2 2 6 Serial Port Console Redirection 41 2 2 7 CPU Configuration 45 2 2 8 PCI Subsystem Settings 46 2 2 9 USB Configuration 48 2 2 10 N...

Страница 4: ...oad Tuning 104 2 4 AMD PBS Menu 105 2 4 1 RAS 106 2 5 Chipset Setup Menu 108 2 5 1 North Bridge 109 2 5 2 Fabric Resource 110 2 6 Server Management Menu 111 2 6 1 System Event Log 113 2 6 2 View FRU Information 114 2 6 3 BMC Network Configuration 115 2 6 4 IPv6 BMC Network Configuration 116 2 7 Security Menu 117 2 7 1 Secure Boot 118 2 8 Boot Menu 120 2 9 Save Exit Menu 122 2 10 BIOS Recovery 123 ...

Страница 5: ...M_P0_C0 DIMM_P0_D0 DIMM_P0_H0 DIMM_P0_G0 DIMM_P0_F0 DIMM_P0_E0 DIMM_P1_L0 DIMM_P1_K0 DIMM_P1_J0 DIMM_P1_I0 DIMM_P1_M0 DIMM_P1_N0 DIMM_P1_O0 DIMM_P1_P0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 17 18 19 20 22 21 23 24 25 26 27 28 31 29 32 33 41 42 34 35 36 37 38 39 40 30 16 ...

Страница 6: ...6Gb s Connector 2 19 SATA1 SATAIII 6Gb s Connector 1 20 SATA0 SATAIII 6Gb s Connector 0 21 SYS_FAN2 System Fan Connector 2 22 BAT Battery Socket 23 SYS_FAN1 System Fan Connector 1 24 F_USB3 Front Panel USB 3 0 Connector 25 F_USB2 USB 2 0 Header 26 FP_1 Front Panel Header 27 IPMB IPMB Connector 28 CN_NCSI NCSI Connector 29 BP_1 HDD Back Plane Board Connector 30 CASE_OPEN Case Open Intrusion Alert H...

Страница 7: ... 7 Block Diagram ...

Страница 8: ...ry and first touch a metal object to eliminate static electricity Prior to installing the motherboard please have it on top of an antistatic pad or within an electrostatic shielding container Before unplugging the power supply cable from the motherboard make sure the power supply has been turned off Before turning on the power make sure the power supply voltage has been set according to the local ...

Страница 9: ...IMM modules up to 256GB supported Memory speed Up to 3200 2933 MHz cket et Security Security LAN 2 x 10GbE LAN ports 1 x Broadcom BCM57416 1 x 10 100 1000 management LAN Socket Socket Security Security Onboard Graphics Integrated in Aspeed AST2600 2D Video Graphic Adapter with PCIe bus interface 1920x1200 60Hz 32bpp DDR4 SDRAM Socket Socket Security Security Storage Interface 4 x 7 pin SATA 6Gb s ...

Страница 10: ...24 pin ATX main power connector 2 x 8 pin ATX 12V power connectors 5 x SlimSAS connectors 4 x SATA 7 pin connects 1 x M 2 slot 2 x CPU fan headers 4 x System fan headers 1 x USB 3 0 header 1 x USB 2 0 header 1 x TPM header 1 x Front panel header 1 x PMBus connector 1 x IPMB connector 1 x Clear CMOS jumper 1 x BIOS recovery jumper Socket Socket Security Security Rear I O Connectors 2 x USB 3 0 port...

Страница 11: ...orage Circular Storage Policy Hardware Inventory Fan Profile System Firewall Power Consumption Power Control LDAP AD RADIUS Support Backup Restore Configuration Remote BIOS BMC CPLD Update Event Log Filter User Management Media Redirection Settings PAM Order Settings SSL Settings SMTP Settings Socket Socket Security Security Operating Properties Operating temperature 10 C to 40 C Operating humidit...

Страница 12: ...g guidelines before you begin to install the CPU Make sure that the motherboard supports the CPU Always turn off the computer and unplug the power cord from the power outlet before installing the CPU to prevent hardware damage Unplug all cables from the power outlets Disconnect all telecommunication cables from their ports Place the system unit on a flat and stable surface Open the system accordin...

Страница 13: ...rdware damage Memory modules have a foolproof design A memory module can be installed in only one direction If you are unable to insert the memory switch the direction 1 4 1 8 Channel Memory Configuration This motherboard provides 16 DDR4 memory slots and supports 8 Channel Technology After the memory is installed the BIOS will automatically detect the specifications and capacity of the memory CPU...

Страница 14: ... the plastic clip at both edges of the DIMM slots to lock the DIMM module 3 Reverse the installation steps when you want to remove the DIMM module 1 2 2 1 4 3 Processor and Memory Module Matrix Table Processor and Memory Module Matrix Table 8 DIMMs CPU CPU0 A1 B1 C1 D1 E1 F1 G1 H1 16 DIMMs CPU0 A1 A0 B1 B0 C1 C0 D1 D0 E1 E0 F1 F0 G1 G0 H1 H0 16 DIMMs CPU0 A1 B1 C1 D1 E1 F1 G1 H1 CPU1 I1 J1 K1 L1 M...

Страница 15: ...M 4DR 3200 4DR 4DR 2933 2S2R 4 Ranks 3200 2S4R 8 Ranks 3200 2S2R 4 Ranks 2S2R 4 Ranks 2933 2S4R 8 Ranks 2S4R 8 Ranks 2933 3DS 2S2R 4 Ranks 2933 2S2R 4 Ranks 2S2R 4 Ranks 2666 2S4R 8 Ranks 2933 2S4R 8 Ranks 2S4R 8 Ranks 2666 DIMM Type DIMM Population Max EPYC 7003 DDR Frequency MHz DIMM 0 RDIMM 1R 1 Rank 3200 2R or 2DR 2 Ranks 3200 LRDIMM 4DR 4 Ranks 3200 2S2R 4 Ranks 3200 2S4R 8 Ranks 3200 3DS 2S2...

Страница 16: ...moving the M 2 SSD Module Follow the steps below to install an optional M 2 SSD module on your motherboard Step1 Insert the M 2 SSD module into the slot Step2 Secure it with the screw tightening as necessary to fasten the M 2 SSD module in place 1 2 ...

Страница 17: ...at up to 10 Gbps data rate See the section below for a description of the states of the LAN port LEDs z ID button with LED When the system identification is active the ID LED on the front back panel glows blue VGA Port Connects to a monitor device v x y z u LAN and ID Button LEDs Link Activity LED Speed LED LAN Port When removing the cable connected to a back panel connector first remove the cable...

Страница 18: ...e turning on the computer make sure the device cable has been securely attached to the connector on the motherboard 1 ATX 11 F_USB2 2 P12V_1 for CPU0 12 FP_1 3 P12V_2 for CPU1 13 BP_1 4 SATA0 SATA1 SATA2 SATA3 14 SPI_TPM 5 SATA_SGP 15 IPMB 6 CPU0_FAN CPU1_FAN 16 CN_NSCI 7 SYS_FAN1 SYS_FAN2 17 LED_BMC 8 SYS_FAN3 SYS_FAN4 18 BAT 9 PMBUS 19 CASE_OPEN 10 F_USB3 CPU0 CPU1 DIMM_P0_A0 DIMM_P0_B0 DIMM_P0_...

Страница 19: ...12V power connector mainly supplies power to the CPU If the 12V power connector is not connected the computer will not start To meet expansion requirements it is recommended that a power supply that can withstand high power consumption be used 500W or greater If a power supply is used that does not provide the required power the result can lead to an unstable or unbootable system ATX P12V_1 P12V_2...

Страница 20: ...SATA 3Gb s standard Each SATA connector supports a single SATA device Pin No Definition 1 GND 2 TXP 3 TXN 4 GND 5 RXN 6 RXP 7 GND 1 7 5 SATA_SGP SATA SGPIO Connector Serial General Purpose Input Output SGPIO is a communication method used between a host bus adapter HBA and a main board Pin No Definition 1 Data Out 2 GND 3 Data In 4 Load 5 Clock 1 5 ...

Страница 21: ...or wire is the ground wire The motherboard supports CPU fan speed control which requires the use of a CPU fan with fan speed control design For optimum heat dissipation it is recommended that a system fan be installed inside the chassis 1 1 Pin No Definition 1 GND 2 12V 3 Sense 4 Speed Control Be sure to connect fan cables to the fan headers to prevent your CPU and system from overheating Overheat...

Страница 22: ...SSRX 12 IntA_P2_D 3 IntA_P1_SSRX 13 GND 4 GND 14 IntA_P2_SSTX 5 IntA_P1_SSTX 15 IntA_P2_SSTX 6 IntA_P1_SSTX 16 GND 7 GND 17 IntA_P2_SSRX 8 IntA_P1_D 18 IntA_P2_SSRX 9 IntA_P1_D 19 Power 10 NC 20 No Pin Pin No Definition Pin No Definition 1 Power 5V 6 USB DY 2 Power 5V 7 GND 3 USB DX 8 GND 4 USB DY 9 No Pin 5 USB DX 10 No Connect 1 2 9 10 1 20 11 10 9 PMBus Connector The Power Management Bus PMBus ...

Страница 23: ...finition 1 Power LED 2 5V Standby 3 No Pin 4 ID LED 5 Power LED 6 ID LED 7 HDD LED 8 System Status LED 9 HDD LED 10 System Status LED 11 Power Button 12 LAN1 Active LED 13 GND 14 LAN1 Link LED 15 Reset Button 16 SMBus Data 17 GND 18 SMBus Clock 19 ID Button 20 Case Open 21 GND 22 LAN2 Actve LED 23 NMI Switch 24 LAN2 Link LED Note Pin 7 Pin 9 are reserved for Gigabyte systems 1 24 23 2 13 BP_1 HDD ...

Страница 24: ...inition 1 Clock 8 No Connect 2 P_3V3_AUX 9 LPC_LAD2 3 LPC_RST 10 No Pin 4 P3V3 11 LPC_LAD3 5 LPC_LAD0 12 GND 6 IRQ_SERIAL 13 LPC_FRAME_N 7 LPC_LAD1 14 GND 1 2 1314 15 IPMB Intelligent Platform Management Bus Connector The Intelligent Platform Management Bus Communications Protocol defines a byte level transport for transferring Intelligent Platform Management Interface Specification IPMI messages ...

Страница 25: ...nk BMC firmware is ready Off AC loss 16 CN_NCSI NCSI Connector Pin No Definition Pin No Definition 1 NCSI_CLK 2 GND 3 NCSI_RX_D0 4 GND 5 NCSI_RX_D1 6 GND 7 NCSI_CRS_DV 8 GND 9 NCSI_RX_ER 10 GND 11 P3V3_AUX 12 GND 13 NCSI_TX_D1 14 GND 15 NCSI_TX_D0 16 GND 17 NCSI_TX_EN 18 GND 19 NCSI_PRESENT 20 P3V3_AUX 19 20 2 1 ...

Страница 26: ...tery with an equivalent one Danger of explosion if the battery is replaced with an incorrect model Contact the place of purchase or local dealer if you are not able to replace the battery by yourself or uncertain about the battery model Used batteries must be handled in accordance with local environmental regulations 1 2 19 CASE_OPEN Case Open Intrusion Alert Header This motherboard provides a cha...

Страница 27: ...mal operation Default 2 3 Clear CMOS data J1 ON OFF 1 HSMB_SEL BIOS Defined 2 N A BIOS Defined 3 BIOS PWD Clear Supervisor Password Normal Default 4 BIOS Recovery BIOS Recovery Mode Normal Default NCSI_SW LAN1 CN_NCSI SW1 OFF SW2 OFF ON OFF 1 2 ON 21 3 Clear CMOS CLR_CMOS Enable Default 3 2 1 ...

Страница 28: ... with caution Inadequate BIOS flashing may result in system malfunction It is recommended that you not alter the default settings unless you need to to prevent system instability or other unexpected results Inadequately altering the settings may result in system s failure to boot If this occurs try to clear the CMOS values and reset the board to default values Refer to the Exit section in this cha...

Страница 29: ...of the North Bridge Server Management Server additional features enabled disabled setup menus Security Change set or disable supervisor and user password Configuration supervisor password allows you to restrict access to the system and BIOS Setup A supervisor password allows you to make changes in BIOS Setup A user password only allows you to view the BIOS settings but not to make changes Boot Thi...

Страница 30: ... displayed on the bottom line of the Main Menu Submenu Help While in a submenu press F1 to display a help screen General Help of function keys available for the menu Press Esc to exit the help screen Help for each item is in the Item Help block on the right side of the submenu When the system is not stable as usual select the Restore Defaults item to set your system to its defaults The BIOS Setup ...

Страница 31: ...version information Processor Information CPU Brand String CPU Speed Processor Core Microcode Patch Displays the technical specifications for the installed processor s Total Memory Note2 Displays the total memory size of the installed memory Memory SpeedNote2 Displays the frequency information of the installed memory VR Information Version Displays VR version information Note1 Functions available ...

Страница 32: ... PI Version Displays AGESA PI version information Onboard LAN Information LAN1 MAC Address Note3 Displays LAN MAC address information LAN2 MAC Address Note3 Displays LAN MAC address information System Date Sets the date following the weekday month day year format System Time Sets the system time following the hour minute second format ...

Страница 33: ... Menu The Advanced Menu displays submenu options for configuring the function of various hardware components Select a submenu item then press Enter to access the related submenu screen When Boot Mode Select is set to UEFI Default ...

Страница 34: ... 34 BIOS Setup When Boot Mode Select is set to Legacy in the Boot Boot Mode Select section ...

Страница 35: ...ble BIOS support for security device OS will not show security device TCG EFI protocol and INT1A interface will not be available Options available Enable Disable Default setting is Enable SPI TPM Support Select Enable to activate TPM support feature Options available Enabled Disabled Default setting is Disabled ...

Страница 36: ... 36 BIOS Setup 2 2 2 PSP Firmware Versions The PSP Firmware Versions page displays the basic PSP firmware version information Items on this window are non configurable ...

Страница 37: ... 37 BIOS Setup 2 2 3 Legacy Video Select Parameter Description OnBrd Ext VGA Select Selects between onboard or external VGA support Options available Auto Onboard External Default setting is Onboard ...

Страница 38: ... 2 4 AST2600 Super IO Configuration Parameter Description AST2600 Super IO Configuration Super IO Chip Displays the super IO chip information Serial Port 1 Configuration Press Enter for configuration of advanced items ...

Страница 39: ... Enabled Disabled Default setting is Enabled Devices Settings Note2 Displays the Serial Port 1 device settings Change Settings Note2 Select an optimal settings for Super IO Device Options available for Serial Port 1 Auto IO 3F8h IRQ 4 IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5 6 7 9 10 11 12 IO 3E8h IRQ 3 4 5 6 7 9 10 11 12 IO 2E8h IRQ 3 4 5 6 7 9 10 11 12 Default setting is Auto Note1 Adv...

Страница 40: ...e Settings Parameter Description Wake System from S5 Enable Disable system wake on alarm event Options available Disabled Fixed Time When Fixed Time is selected system will wake on the hr min sec specified Default setting is Disabled ...

Страница 41: ...M1 Serial Over LAN Console Redirection Settings Press Enter to configure advanced items Please note that this item is configurable when COM1 Serial Over LAN Console Redirection is set to Enabled Terminal Type Selects a terminal type to be used for console redirection Options available VT100 VT100 ANSI VT UTF8 Default setting is ANSI Bits per second Selects the transfer rate for console redirection...

Страница 42: ...is 1 Flow Control Flow control can prevent data loss from buffer overflow When sending data if the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty a start signal can be sent to re start the flow Hardware flow control uses two wires to send start stop signals Options available None Hardware RTS CTS Default setting is None VT UTF8 Combo Key Suppo...

Страница 43: ...MS Console Redirection Note EMS console redirection allows the user to configure Console Redirection Settings to support Out of Band Serial Port management Options available Enabled Disabled Default setting is Disabled Serial Port for Out of Band EMS Console Redirection Settings Press Enter to configure advanced items Please note that this item is configurable when Serial Port for Out of Band Mana...

Страница 44: ...ta loss from buffer overflow When sending data if the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty a start signal can be sent to re start the flow Hardware flow control uses two wires to send start stop signals Options available None Hardware RTS CTS Software Xon Xoff Default setting is None ...

Страница 45: ...Configuration Parameter Description SVM Mode Enable Disable the CPU Virtualization Options available Enabled Disabled Default setting is Enabled CPU 0 1 Information Press Enter to view the memory information related to CPU 0 1 ...

Страница 46: ... 46 BIOS Setup 2 2 8 PCI Subsystem Settings ...

Страница 47: ...troller Note3 Enable Disable the onboard LAN devices Options available Enabled Disabled Default setting is Enabled Onboard LAN I O ROM Note3 Enable Disable the onboard LAN devices and initializes device expansion ROM Options available Enabled Disabled Default setting is Enabled PCI Devices Common Settings Above 4G Decoding Enable Disable memory mapped I O to 4GB or greater address space Above 4G D...

Страница 48: ...rt Enable Disable the Legacy USB support function AUTO option disables legacy support if no USB devices are connected DISABLE option will keep USB devices available only for EFI applications Options available Auto Enabled Disabled Default setting is Enabled XHCI Hand off Enable Disable the XHCI USB 3 0 Hand off support Options available Enabled Disabled Default setting is Enabled USB Mass Storage ...

Страница 49: ...Device reset time out Selects the time out value during a USB mass storage device reset Options available 10 sec 20 sec 30 sec 40 sec Default setting is 20 sec Device power up delay Maximum time the device will take before it properly reports itself to the Host Controller Auto uses default value for a Root port it is 100 ms for a Hub port the delay is taken from Hub descriptor Options available Au...

Страница 50: ...the Ipv4 HTTP feature Options available Enabled Disabled Default setting is Disabled Ipv6 PXE Support Note Enable Disable the Ipv6 PXE feature Options available Enabled Disabled Default setting is Enabled Ipv6 HTTP Support Note Enable Disable the Ipv6 HTTP feature Options available Enabled Disabled Default setting is Disabled PXE boot wait time Note Wait time in seconds to press ESC key to abort t...

Страница 51: ...iguration Parameter Description NVMe Configuration Displays the NVMe devices connected to the system NVMe LED Control Enable Disable NVMe LED Control Options available System Default Disabled Enabled Default setting is System Default ...

Страница 52: ... 52 BIOS Setup 2 2 12 SATA Configuration Parameter Description SATA Configuration Displays the installed HDD devices information System will automatically detect HDD type ...

Страница 53: ... 13 Graphic Output Configuration Parameter Description Output Device Type Selects output device type Options available First loaded Device Onboard Device External Device Specific Device Default setting is Onboard Device ...

Страница 54: ... 54 BIOS Setup 2 2 14 AMD Mem Configuration Status Parameter Description CPU0 1 Press Enter to view the memory configuration status related to CPU 0 1 ...

Страница 55: ...figuration of advanced items Enroll Cert Press Enter to enroll a certificate Enroll Cert Using File Cert GUID Input digit character in 1111111 2222 3333 4444 1234567890ab format Commit Changes and Exit Discard Changes and Exit Delete Cert Client Cert Configuration Press Enter for configuration of advanced items ...

Страница 56: ... Configuration Parameter Description iSCSI Initiator Name Add an Attempt Press Enter to configure advanced items Delete Attempts Press Enter to configure advanced items Change Attempt Order Press Enter to configure advanced items ...

Страница 57: ...Number of VFs Per PF Configures the number of Virtual Functions Per Physical Function in multiples of 8 1 128 This field is only applicable when SR IOV is enabled Default setting is 8 SR IOV Enable Disable Single Root I O Virtualization Options available Enabled Disabled Default setting is Enabled Number of MSI X Vectors per VF Configures the number of MSI X Vectors per VF 0 128 Default setting is...

Страница 58: ...al Bridging mode Options available VEB VEPA None Default setting is VEB Enable PME Capability Enable Disable PME Capability support Options available Enabled Disabled Default setting is Disabled Flow Offload Options available Enabled Disabled Default setting is Disabled Live Firmware Upgrade Options available Enabled Disabled Default setting is Disabled Adapter Error Recovery Options available Ena...

Страница 59: ... No Retry 1 Retry 2 Retries 3 Retries 4 Retries 5 Retries 6 Retries Indefinite Retries Default setting is No Retry iSCSI Boot Configuration Menu Press Enter to configure advanced items Blink LEDs Identifies the physical network port by blinking the associated LED Press the numeric keys to adjust desired values Link Status Specifies the link status of the port Physical Link Speed Displays the techn...

Страница 60: ...t setting is Enabled This item is configurable when TCP IP Parameters via DHCP is set to Disabled iSCSI Parameters via DHCP Acquires iSCSI Parameters via DHCP Options available Enabled Disabled Default setting is Disabled CHAP Authentication Enable Disable the CHAP authentication Options available Enabled Disabled Default setting is Disabled Boot to iSCSI Target Enable Disable booting to iSCSI tar...

Страница 61: ...lt setting is IPv4 iSCSI Initiator Parameters Press Enter to configure advanced items IP Address Configures the initiator IP address Subnet Mask Configures the IP subnet mask Default Gateway Configures the default gateway IP address Primary DNS Configures the primary DNS IP address Secondary DNS Configures the secondary DNS IP address iSCSI Name Configures the iSCSI name CHAP ID Configures the Cha...

Страница 62: ...he Challenge Handshake Authentication Protocol CHAP Secret 12 to 16 characters in length Secondary Device Press Enter to configure advanced items Secondary Device Inputs the secondary device MAC address Use Independent Target Portal Use Independent target portal when multipath I O is enabled Options available Enabled Disabled Default setting is Disabled Use Independent Target Name Use Independent ...

Страница 63: ...ng VLAN Press the keys to increase or decrease the desired values The valid range is from 0 to 4094 Priority Sets 802 1Q Priority for a new VLAN or an existing VLAN Press the keys to increase or decrease the desired values The valid range is from 0 to 7 Add VLAN Press Enter to create a new VLAN or update an existing VLAN Configured VLAN List Remove VLAN Press Enter to remove an existing VLAN ...

Страница 64: ...Note Options available Enabled Disabled Default setting is Enabled Local IP Address Note Press Enter to configure local IP address Local NetMask Note Press Enter to configure local NetMask Local Gateway Note Press Enter to configure local Gateway Local DNS Servers Note Press Enter to configure local DNS servers Save Changes and Exit Press Enter to save all configurations Note This item appears whe...

Страница 65: ... for the device The string is colon separated e g ff dd 88 66 cc 1 2 3 DAD Transmit Count The number of consecutive Neighbor solicitation messages sent while performing Duplicate Address Detection on a tentative address A value of zero indicates that Duplicate Address Detection is not performed Policy Options available automatic manual Default setting is automatic Save Changes and Exit Press Enter...

Страница 66: ...etup 2 3 AMD CBS Menu AMD CBS menu displays submenu options for configuring the CPU related information that the BIOS automatically sets Select a submenu item then press Enter to access the related submenu screen ...

Страница 67: ... 67 BIOS Setup 2 3 1 CPU Common Options ...

Страница 68: ... Auto 253 ASIDs 509 ASIDs Default setting is Auto SEV ES ASID Space Limit Control Space limit control for SEV ES ASIDs Options available Auto Manual Default setting is Auto Streaming Stores Control Enable Disable the Streaming Stores functionality Options available Auto Enabled Disabled Default setting is Auto Local APIC Mode Sets the Local APIC Mode Options available Auto xAPIC x2APIC Default set...

Страница 69: ...to zero for analysis purpose as long as OS supports it Options available Disabled Enabled Auto Default setting is Auto REP MOV STOS Streaming Allows REP MOVS STOS to use non caching streaming stores for large sizes Options available Disabled Enabled Default setting is Disabled IBS hardware workaround Sets if using IBS execution sampling without software workaround for erratum 1 285 May impact perf...

Страница 70: ...pted you can control the number of CCDs to be used and the number of cores to be used CCD Control Options available Auto 2 CCDs 3 CCDs 4 CCDs 6 CCDs Default setting is Auto Core Control Options available Auto ONE 1 0 TWO 2 0 THREE 3 0 FOUR 4 0 FIVE 5 0 SIX 6 0 SEVEN 7 0 Default setting is Auto SMT Control Can be used to disable symmetric multithreading To re enable SMT a POWER CYCLE is needed afte...

Страница 71: ...ble Default setting is Auto L1 Region Prefetcher Use memory access history to fetch additional lines when the data access for a given instruction tends to be followed by other data accesses Enable Disable L1 Region Prefetcher Options available Auto Enable Disable Default setting is Auto L2 Stream HW Prefetcher Enable Disable L2 Stream HW Prefetcher Options available Auto Enable Disable Default set...

Страница 72: ... 72 BIOS Setup 2 3 1 3 Core Watchdog Parameter Description Core Watchdog Core Watchdog Timer Enable Enable Disable CPU Watchdog Timer Options available Auto Enabled Disabled Default setting is Auto ...

Страница 73: ... Disable DF Sync Flood propagation Options available Auto Sync flood disabled Sync flood enabled Default setting is Auto Freeze DF module queues on error Options available Auto Enabled Disabled Default setting is Auto CC6 memory region encryption Controls whether or not the CC6 save restor memory is encrypted Options available Auto Enabled Disabled Default setting is Auto System probe filter Enabl...

Страница 74: ...e Poison scrubber control feature Options available Auto Enabled Disabled Default setting is Auto Redirect scrubber control Enable Disable the Redirect scrubber control feature Options available Auto Enabled Disabled Default setting is Auto Redirect scrubber limit Sets the redirect scrubber limit Options available Auto 2 4 8 Infinite Default setting is Auto Periodic Directory Rinse Controls Period...

Страница 75: ...tions available Auto 256Bytes 512Bytes 1KB 2KB Default setting is Auto 1TB remap Enable Disable to remap DRAM out of the space just below the 1TB boundary The ability to remap depends on DRAM configuration NPS and interleaving selection and may not always be possible Options available Auto Do not remap Attempt to remap Default setting is Auto DRAM map inversion Enable Disable the DRAM map inversio...

Страница 76: ... Options available Auto Enabled Disabled Default setting is Auto ACPI SLIT Distance Control Determines how the SLIT distances are declared Options available Auto Manual Default setting is Auto ACPI SLIT remote relative distance Sets the remote socket distance for 2P systems as near 2 8 or far 3 2 Options available Auto Near Far Default setting is Auto ...

Страница 77: ...uto Enabled Disabled Default setting is Auto CAKE CRC perf bounds Control Options available Auto Manual Default setting is Auto 4 link xGMI max speed Specifies the max speed of 4 link xGMI Default setting is Auto xGMI TXEQ Mode Configures xGMI TXEQ RX vetting Mode Options available Auto TXEQ_Disabled TXEQ_Lane TXEQ_Link TXEQ_RX_Vet Default setting is Auto xGMI 18GACOFC Configures xGMI 18GACOFC Opt...

Страница 78: ... Common Options DDR4 Common Options Press Enter for configuration of advanced items DRAM Memory Mapping Press Enter for configuration of advanced items NVDIMM Press Enter for configuration of advanced items Memory MBIST Press Enter for configuration of advanced items ...

Страница 79: ... Default setting is Auto Note To enable 2 DIMMs per Channel at 3200MHz function select Accept at warning message change Overclock from Auto to Enabled and then set memory speed to 3200MHz DRAM Controller Configuration Press Enter to configure DRAM Controller Configuration CAD Bus Configuration Press Enter to configure CAD Bus Configuration Data Bus Configuration Press Enter to configure Data Bus C...

Страница 80: ...lue 6 1 UrgRefLimit Specifies the value Valid value 6 1 DRAM Maximum Activate Count Options available Untested MAC 700K 600K 500K 400K 300K 200K Unlimited MAC Auto Default setting is Auto DRAM Refresh Rate Options available 7 8 usec 3 9 usec Default setting is Auto Self Refresh Exit Staggering Options available Disabled Trfc 3 Trfc 4 Default setting is Disabled Cmd2T Selects the Cmd2T mode on ADDR...

Страница 81: ...iguration CAD Bus Timing User Controls Setup time on CAD bus signals to Auto or Manual Options available Auto Manual Default setting is Auto CAD Bus Drive Strength User Controls Drive Strength on CAD bus signals to Auto or Manual Options available Auto Manual Default setting is Auto ...

Страница 82: ...3 1 3 Data Bus Configuration Parameter Description Data Bus Configuration Data Bus Configuration User Controls Specifies the mode for drive strength to Auto or Manual Options available Auto Manual Default setting is Auto ...

Страница 83: ...ction Options available Auto Enabled Disabled Default setting is Auto Max Parity Error Replay Configures the Max Parity Error Replay 0 0x3f Default setting is 8 Please note that this item is configurable when DRAM Address Command Parity Retry is set to Enabled Write CRC Enable Enable Disable the Write CRC function Options available Auto Enabled Disabled Default setting is Auto DRAM Write CRC Enabl...

Страница 84: ...tems DRAM ECC Symbol Size Configures the DRAM ECC Symbol Size Options available Auto x4 x8 x16 Default setting is Auto DRAM ECC Enable Enable Disable DRAM ECC When set to Auto it will set ECC to enable Options available Auto Enabled Disabled Default setting is Auto DRAM UECC Retry Enable Disable DRAM UECC Retry Options available Auto Enabled Disabled Default setting is Auto ...

Страница 85: ...scription Security TSME Enable Disable transparent secure memory encryption Options available Auto Enabled Disabled Default setting is Auto Data Scramble Enable Disable Data Scrambling Options available Auto Enabled Disabled Default setting is Auto ...

Страница 86: ... Training DFE Read Training Perform 2D Read Training with DFE on Options available Auto Enable Disable Default setting is Auto FFE Write Training Perform 2D Write Training with FFE on Options available Auto Enable Disable Default setting is Auto PMU Pattern Bits Controls Options available Auto Manual Default setting is Auto ...

Страница 87: ...l No help string Options available Auto Enabled Disabled Default setting is Auto BankGroupSwapAlt Configures the BankGroupSwapAlt Options available Auto Enabled Disabled Default setting is Auto Address Hash Bank Enable Disable bank address hashing Options available Auto Enabled Disabled Default setting is Auto Address Hash CS Enable Disable CS address hashing Options available Auto Enabled Disable...

Страница 88: ...VDIMM Parameter Description NVDIMM Displays the information of the devices controllers if installed Disable NVDIMM N Feature Enable Disable NVDIMM N feature for memory margin tool Options available No Yes Default setting is NO ...

Страница 89: ...te Enable Disable MBIST Aggressor test Options available Auto Enabled Disabled Default setting is Auto MBIST Per Bit Slave Die Reporting Note Enable Disable to report 2D data eye results in ABL log for each DQ Chipselect and Channel Options available Auto Enabled Disabled Default setting is Auto Data Eye Press Enter to configure advanced items Memory Healing BIST Options available Disabled BIOS Me...

Страница 90: ...ault setting is Vendor Tests Enabled PMU Mem BIST Test Select Note1 Selects the algorithms to use with PMU Mem BIST Default setting is Algorithm 1 2 3 4 5 Mem BIST Post Package Repair Type Note1 Selects the repair type for dram errors found in the BIOS memory BIST Options available Soft Repair Hard Repair No Repairs Test only Default setting is Soft Repair Note1 This item is available when Memory ...

Страница 91: ...ol function Options available Enabled Disabled Default setting is Disabled Aggressor Static Lane Select Upper 32 bits This item is configurable when Aggressor Static Lane Control is set to Enabled Aggressor Static Lane Select Lower 32 bits This item is configurable when Aggressor Static Lane Control is set to Enabled Aggressor Static Lane Select ECC This item is configurable when Aggressor Static ...

Страница 92: ...d Worst Case Margin Granularity Configures Worst Case Margin Granularity Options available Per Chip Select Per Nibble Default setting is Per Chip Select Read Voltage Sweep Step Size Configures the step size for read Data Eye voltage sweep Options available 1 2 4 Default setting is 1 Read Timing Sweep Step Size Configures the step size for read Data Eye timing sweep Options available 1 2 4 Default ...

Страница 93: ...Disable Alternative Routing ID Interpretation Options available Auto Enabled Disabled Default setting is Auto PCIe ARI Enumeration ARI Forwarding Enable for each downstream port Options available Auto Enable Disable Default setting is Auto PCIe Ten Bit Tag Support Enable Disable PCIe ten bit tags for supported devices Auto Disabled Options available Auto Enabled Disabled Default setting is Auto SM...

Страница 94: ...setting is Auto Preferred IO Preferred IO select type Manual Bus Number manually Auto Default Options available Auto Manual Default setting is Auto Data Link Feature Cap Enable Disable the data link feature capability Options available Auto Enabled Disabled Default setting is Auto CV test Enable Disable the running PCIECV tool support Options available Auto Enabled Disabled Default setting is Auto...

Страница 95: ...to define the RC thermal model only Options available Auto Manual Default setting is Auto cTDP Display cTDP information EfficiencyModeEn Options available Auto Enabled Default setting is Auto Package Power Limit Control Note Selects use the fused PPT or set customized PPT PPT will be used as the ASIC power limit Options available Auto Manual Default setting is Auto Package Power Limit Display Pack...

Страница 96: ...fault setting is Auto DLWM Support Enable Disable the DLWM support Options available Auto Enabled Disabled Default setting is Auto BoostFmaxEn Options available Auto Enabled Default setting is Auto EDC Current Tracking Options available Enable Disable Default setting is Disable LCLK Frequency Control Press Enter for advanced configuration DF PSTATE Mode Select Selects the DF PState Mode Option ava...

Страница 97: ...it of 0 indicates LOW severity NBIO SyncFlood Generation The value may be used to mask SyncFlood caused by NBIO RAS options Options available Auto Enabled Disabled Default setting is Auto NBIO SyncFlood Reporting The value may be used to enable SyncFlood reporting to APML Options available Auto Enabled Disabled Default setting is Auto Egress Poison Mask High Enables mask for masking of errors logg...

Страница 98: ...ed Default setting is Disabled SLINK Read Response Error Handling Options available Enabled Trigger MCOMMIT Error Log Errors in MCA Default setting is Log Errors in MCA Log Poison Data from SLINK Enable Disable the Log Poison Data from SLINK feature Options available Enabled Disabled Default setting is Disabled PCIe Aer Reporting Mechanism Selects the method of reporting AER errors from PCI Expres...

Страница 99: ...arameter Description FCH Common Options AC Power Loss Options Press Enter for configuration of advanced items FCH RAS Options Press Enter for configuration of advanced items Miscellaneous Options Press Enter for configuration of advanced items ...

Страница 100: ...S Setup 2 3 5 1 AC Power Loss Options Parameter Description AC Power Loss Options AC Loss Control Selects the AC Loss Control Method Options available Power Off Power On Last State Default setting is Last State ...

Страница 101: ... ALink RAS Support Enable Disable the ALink RAS Support Options available Auto Enabled Disabled Default setting is Auto Reset after sync flood Enables AB to forward downstream sync flood message to system controller Options available Auto Enabled Disabled Default setting is Auto ...

Страница 102: ... 102 BIOS Setup 2 3 5 3 Miscellaneous Options Parameter Description Miscellaneous Options Boot Timer Enable Enable Disbale Boot Timer Options available Auto Enabled Disabled Default setting is Auto ...

Страница 103: ... UART0 SOC UART1 Auto Default setting is Auto ABL Basic Console Out Control Note Enable Disable the Basic ConsoleOut function for ABL Options available Auto Enabled Disabled Default setting is Auto ABL PMU message Control Note To Control the total number of PMU debug messages Options available Auto Detailed debug message Coarse debug message Stage completion Firmware completion message only Defaul...

Страница 104: ...eter Description Workload Tuning Workload Profile Select the profile for different workloads Default setting is Auto Performance Tracing Enable to allow capturing performance traces Options available Auto Enabled Disabled Default setting is Auto ...

Страница 105: ...iguration of advanced items iLA TraceMemoryEn Reserved 1M bytes MMIO space on 1M boundary when iLA TraceMemoryEn enabled Options available Enabled Disabled Default setting is Disabled iLA TraceMemoryEn reserved MMIO Reserved function SRIS mode debug Control SRIS mode debug Options available Auto Enabled Disabled Default setting is Auto SRIS Autodetect Control SRIS Autodetect Options available Auto...

Страница 106: ...eriod GHES Notify Type Selects the Notification type for deferred corrected errors Options available Polled SCI Default setting is Polled GHES UnCorr Notify Type Selects the Notification type for uncorrected errors Options available Polled NMI Default setting is NMI PCIe GHES Notify Type Selects the Notification type for PCIe corrected errors Options available Polled SCI Default setting is Polled ...

Страница 107: ...R Notify Type Selects the Notification type for CCIX deferred error Options available Polled SCI Default setting is Polled CCIX GHES Corrected Err Notify Type Selects the Notification type for CCIX corrected error Options available Polled SCI Default setting is Polled DDR4 DRAM Hard Post Package Repair This feature allows spare DRAM rows to replace malfunctioning rows via an in field repair mechan...

Страница 108: ...ter to access the related submenu screen Parameter Description PCIe Compliance Mode Options available On Off Default setting is Off Program All VR Enable Disable program all VR on MB Options available Enabled Disabled Default setting is Enabled North Bridge Press Enter for configuration of advanced items Fabric Resource Press Enter for configuration of advanced items ...

Страница 109: ...etup 2 5 1 North Bridge Parameter Description North Bridge Configuration Memory Information Total Memory Displays the total memory information CPU 0 1 Information Press Enter to view information related to CPU 0 1 ...

Страница 110: ... 110 BIOS Setup 2 5 2 Fabric Resource Parameter Description Fabric Resource CPU 0 1 NBIO_ PCIe Bus Number Change CPU 0 1 NBIO_ PCIe Bus Number ...

Страница 111: ...Enable Disable OS Watchdog Timer function Options available Enabled Disabled Default setting is Disabled OS Wtd Timer Timeout Note Configures OS Watchdog Timer Options available 5 minutes 10 minutes 15 minutes 20 minutes Default setting is 10 minutes OS Wtd Timer Policy Note Configure OS Watchdog Timer Policy Options available Reset Do Nothing Power Down Default setting is Reset Wait BMC Ready Pos...

Страница 112: ...Event Log Press Enter to configure advanced items View FRU Information Press Enter to view the FRU information BMC network configuration Press Enter to configure advanced items IPv6 BMC Network Configuration Press Enter to configure advanced items ...

Страница 113: ...ase SEL Choose options for erasing SEL Options available No Yes On next reset Yes On every reset Default setting is No When SEL is Full Choose options for reactions to a full SEL Options available Do Nothing Erase Immediately Default setting is Do Nothing Custom EFI Logging Options Log EFI Status Codes Enable Disable the logging of EFI Status Codes if not already converted to legacy Options availa...

Страница 114: ...U Information The FRU page is a simple display page for basic system ID information as well as System product information Items on this window are non configurable Note The model name will vary depends on the product you purchased ...

Страница 115: ... IP address Displays IP Address information Subnet mask Displays Subnet Mask information Please note that the IP address must be in three digitals for example 192 168 000 001 Router IP address Displays the Router IP Address information Station MAC address Displays the MAC Address information VLAN Support Set BMC to enable disable VLAN support Options available Enabled Disabled Default setting is D...

Страница 116: ... network during BIOS phase Options available Unspecified Disable Enable Default setting is Enable IPv6 BMC Lan IP Address Source Selects to configure LAN channel parameters statically or dynamically by BIOS or BMC Options available Unspecified Static Dynamic Obtained by BMC running DHCP Default setting is Dynamic Obtained by BMC running DHCP IPv6 BMC Lan IP Address Prefix Length Check if the IPv6 ...

Страница 117: ...all settings in the Setup Utility User Password Entering this password will restrict a user s access to the Setup menus To enable or disable this field a Administrator Password must first be set A user can only access and modify the System Time System Date and Set User Password fields Parameter Description Administrator Password Press Enter to configure the administrator password User Password Pre...

Страница 118: ...all the applications that are running during the booting process to be pre signed with valid digital certificates This way the system knows all files being loaded before Windows loads to the login screen have not been tampered with When set to Standard it will automatically load the Secure Boot keys form the BIOS databases When set to Custom you can customize the Secure Boot settings and manually ...

Страница 119: ...te Key Exchange Keys KEK Displays the current status of the Key Exchange Key Database KEK Press Enter to configure a new KEK or load additional KEK from storage devices Options available Update Append Authorized Signatures DB Displays the current status of the Authorized Signature Database Press Enter to configure a new DB or load additional DB from storage devices Options available Update Append ...

Страница 120: ...alues Bootup NumLock State Enable Disable the Bootup NumLock function Options available On Off Default setting is Off Quiet Boot Enable Disable showing the logo during POST Options available Enabled Disabled Default setting is Enabled Setup Flash Press Enter to run setup flash Dump full Setup Data Press Enter to dump full setup data to file Dump non default Setup Data Press Enter to dump non defau...

Страница 121: ...ure the boot priority By default the server searches for boot devices in the following sequence 1 Hard drive 2 CD COM DVD drive 3 USB device 4 Network 5 UEFI UEFI Network Drive BBS Priorities Press Enter to configure the boot priority UEFI Application Boot Priorities Press Enter to configure the boot priority ...

Страница 122: ...ne so far to any of the setup options Options available Yes No Default Options Restore Defaults Loads the default settings for all BIOS setup parameters Setup Defaults are quite demanding in terms of resources consumption If you are using low speed memory chips or other kinds of low performance components and you choose to load these settings the system might not function properly Options availabl...

Страница 123: ...s corrupt the boot block can be used to restore the BIOS to a working state To restore your BIOS please follow the instructions listed below Recovery Instruction 1 Copy the XXX rom to USB diskette 2 Setting BIOS Recovery jump to enabled status 3 Boot into BIOS recovery 4 Run Proceed with flash update 5 BIOS updated ...

Страница 124: ...PL was not found 3 DXE Core Firmware Volume was not found 4 Recovery failed 4 S3 Resume failed 7 Reset PPI is not available 2 11 2 DXE Beep Codes of Beeps Description 1 Invalid password 4 Some of the Architectural Protocols are not available 5 No Console Output Devices are found 5 No Console Input Devices are found 6 Flash update is failed 7 Reset protocol is not available 8 Platform PCI resource ...