background image

Appendix

Safety and Cleaning

22 of 27

User Manual Cash Control Unit 1.0/Edition 12.2009

ID No. 30033908

A

Safety and Cleaning

Safety Information

 

Read the following safety instructions carefully. They have been com-
piled for your safety and to ensure proper application of Cash Control 
Unit in accordance with corresponding regulations. 
Failure to observe the following general safety instructions can lead to in-
jury of the operator and/or damage of Cash Control Unit. In the event 
the instructions are not observed, Giesecke & Devrient is exempt from 
accident liability. This exemption also applies during the warranty period.

Cash Control Unit has been assembled and tested according to the basic 
safety requirements for low voltage applications (LVD) and has left the 
manufacturer in flawless condition. To maintain this condition and to en-
sure safe operation, the operator must not only observe the correct op-
erating conditions for Cash Control Unit but also the following general 
safety instructions:
– Cash Control Unit must be used as specified in the product documen-

tation. 

– Electrical installation of Cash Control Unit must meet Swedish re-

quirements and regulations.

– Only use the power cable that comes with Cash Control Unit. Do not 

use an extension cable to connect Cash Control Unit.

– Make sure Cash Control Unit is well ventilated. 
– Do not place Cash Control Unit close to heat sources or in damp 

places.

– Do not expose Cash Control Unit to direct sunlight.
– Do not expose Cash Control Unit to liquids.
– Only devices or parts that fulfill the requirements of Safety Extra Low 

Voltage circuits (SELV) – as stipulated by IEC 60950-1 – may be con-
nected to the available interfaces.

– Cash Control Unit can only be disconnected completely if the power 

cable is removed from the wall plug or from Cash Control Unit. Make 
sure there is free and easy access to enable disconnection.

– Only original accessories that have been approved by Giesecke & 

Devrient may be used.

– Safe operation is no longer possible if any of the following apply.

– Cash Control Unit is visibly damaged
– Cash Control Unit is no longer functioning

In this case, Cash Control Unit must be switched off and it must 
be ensured that Cash Control Unit can no longer be operated.

Содержание Cash Control Unit 1.0

Страница 1: ...Cash Control Unit 1 0 Certified Transaction Logging for Cash Registers in Sweden User Manual Edition 12 2009...

Страница 2: ...trademarks or trademarks of Kingston Technology Company Inc Lexar is a trademark of Lexar Media Inc Panasonic is a registered trademark of Panasonic Corporation PNY is a registered trademark of PNY T...

Страница 3: ...4 1 Understanding Cash Control Unit 5 1 1 Connections and SD Slot 6 1 2 LEDs 8 1 3 DIP Switches 9 1 4 Security Seal 11 1 5 Product Label 13 2 Working with Cash Control Unit 15 2 1 Connecting and Disco...

Страница 4: ...Contents User Manual Cash Control Unit 1 0 Edition 12 2009 ID No 30033908...

Страница 5: ...see 1 4 Security Seal on page 11 and see 1 5 Product Label on page 13 Features Cash Control Unit comprises the following features Type A configuration 2 GB internal flash memory for at least seven mil...

Страница 6: ...7 7B1 IEC 721 3 7 7C1L IEC 721 3 7 7M1 IEC 721 3 7 7M2 drop Brand Size and Format Digi Photo Premium 1GB SD 2GB SD FujiFilm 1GB SD 4GB SDHC GreenMemory 4GB SDHC 8GB SDHC Kingston 2GB SD 4GB SDHC Lexar...

Страница 7: ...2009 3 of 27 ID No 30033908 CE EN 55022 Category B EN 55024 EN 60950 1 RoHS WEEE Protection class IP41 Delivery Extent The Cash Control Unit package comprises Cash Control Unit Power supply RS232 cabl...

Страница 8: ...rized tax authority of ficers and cashiers Notational Conventions The following symbols are used in this manual Tips give advice about the best way to do something or useful informa tion on special as...

Страница 9: ...ontrol Unit User Manual Cash Control Unit 1 0 Edition 12 2009 5 of 27 ID No 30033908 1 Understanding Cash Control Unit This chapter describes the basic principles of Cash Control Unit and pro vides ba...

Страница 10: ...as power supply only The serial port is used to communicate with the ECR via the RS232 cable provided Communication speed can be set using the DIP switches see 1 3 DIP Switches on page 9 Serial Port P...

Страница 11: ...Unit provides an SD slot for transferring data to a storage card Fig 4 SD slot The SD slot is always covered by a seal to prevent tampering For more information on seal placement and how to insert the...

Страница 12: ...ate ON Green DATA Yellow ERROR Red Normal operation on off off Data transfer to SD on blinking off Data transfer to SD completed on on off SD card removed after transfer com pleted ie normal operation...

Страница 13: ...hes 1 and 2 are used in this configuration of Cash Control Unit In the following table UP means towards the top of Cash Control Unit and DOWN means towards the bottom of Cash Control Unit as indicated...

Страница 14: ...009 ID No 30033908 Seal The DIP switches should be sealed after being set to prevent accidentally changing the configuration and to prevent any dust or liquids from en tering the housing The figure be...

Страница 15: ...seal is destroyed when it is removed When the seal is peeled back it leaves visible marks on Cash Control Unit Any tampering attempts aimed at illicitly detaching a seal for example by means of solven...

Страница 16: ...27 User Manual Cash Control Unit 1 0 Edition 12 2009 ID No 30033908 Fig 9 Security seals over SD slot and on the front of Cash Control Unit Fig 10 Security seal on the back of Cash Control Unit Fig 1...

Страница 17: ...ope Cash Control Unit is certified in accordance with Swedish Tax Agency regulation SKVFS 2009 2 The serial and certificate numbers and the certification seal are found on the product label attached t...

Страница 18: ...Understanding Cash Control Unit Product Label 14 of 27 User Manual Cash Control Unit 1 0 Edition 12 2009 ID No 30033908...

Страница 19: ...Control Unit 1 0 Edition 12 2009 15 of 27 ID No 30033908 2 Working with Cash Control Unit This chapter describes how to connect and disconnect Cash Control Unit and how to transfer control data from C...

Страница 20: ...ly experienced per son Fig 13 Cash Control Unit connections Connecting Cash Control Unit To connect Cash Control Unit to the electronic cash register 1 Set the DIP switches to the communication speed...

Страница 21: ...g This can take about 30 sec onds Cash Control Unit is ready for use Disconnecting Cash Control Unit Do not disconnect Cash Control Unit from power supply if not necessary Make sure no data transfer i...

Страница 22: ...bel on page 13 How to Proceed No receipts can be processed while data is being transferred from Cash Control Unit Fig 15 Inserting storage card To transfer data from Cash Control Unit to a storage car...

Страница 23: ...Data User Manual Cash Control Unit 1 0 Edition 12 2009 19 of 27 ID No 30033908 6 When data transfer has been completed and the yellow DATA LED has stopped blinking remove the storage card from the SD...

Страница 24: ...Working with Cash Control Unit Transferring Data 20 of 27 User Manual Cash Control Unit 1 0 Edition 12 2009 ID No 30033908...

Страница 25: ...Appendix User Manual Cash Control Unit 1 0 Edition 12 2009 21 of 27 ID No 30033908 Appendix The appendix contains additional information on Cash Control Unit and the index...

Страница 26: ...rol Unit must be used as specified in the product documen tation Electrical installation of Cash Control Unit must meet Swedish re quirements and regulations Only use the power cable that comes with C...

Страница 27: ...wer cable wires must be selected according to the maximum electrical specifications on the product label as stipulated by EN60950 1 VDE0100 EN60204 or UL508 regulations The devices do not generally fu...

Страница 28: ...d of with domes tic waste Consumers are obliged by law to return electrical and electronic de vices at the end of their service lives to the public collecting points set up for this purpose or point o...

Страница 29: ...Set Ready DTR Data Terminal Ready ECR electronic cash register FAT File Allocation Table GND Ground LED Light Emitting Diode LVD Low Voltage Directive RS232 Recommended Standard 232 a standard for ser...

Страница 30: ...Appendix Glossary 26 of 27 User Manual Cash Control Unit 1 0 Edition 12 2009 ID No 30033908...

Страница 31: ...procedure 16 connections 6 conventions 4 D delivery extent 3 DIP switches 9 seal 10 disconnect procedure 17 disposal 24 F features 1 L LEDs 8 N notational conventions 4 P power supply 6 product label...

Отзывы: