background image

3

Specifications - Model LP250-5100HK

 

U. S. .............................................. Metric

Volume

 

 .......................................................................................... 26.0 GPM

 

 .............................. 98.4 LPM

Discharge Pressure

  ................................................................................

2200 PSI

  ..................................

151.7 BAR

Inlet Pressure

  .........................................................................................

90 PSI  ...................................... 6.2 BAR

Speed  ............................................................................................................................................. 1000 RPM
Plunger Diameter  .......................................................................... 1.26”

 

 ............................................ 32mm

Stroke ............................................................................................. 1.65” ............................................. 42mm 

                                       

Crankcase Oil Capacity

 .........................................................................

100 fl.oz.

  ..........................................

2.95 L

Temperature of Pumped Fluids

 ............................................................

140 

o

F

  .................................................

60 

o

C

Inlet Port .................................................................................................................................

 

3 x 1-1/2” BSP

Discharge Port

  ..........................................................................................................................................  

3 x 1” BSP

Crankshaft Mounting

  ...............................................................................................................................  

Either Side

Shaft Rotation

  ....................................................................................................

Top of Pulley Towards Fluid End

Weight  ........................................................................................... 110 lbs. 

 ...........................................

49.9 kg

Crankshaft Diameter ...................................................................... 1.38” ............................................ 35 mm

PULLEY INFORMATION

Pulley selection and pump speed are based on a 

1725 RPM motor and “B” section belts.  When 

selecting desired GPM, allow for a ±5% toler-

ance on pumps output due to variations in pul-

leys, belts and motors among manufacturers.

1. Select GPM required, then select appropriate 

motor and pump pulley from the same line.

2. The desired pressure is achieved by selecting 

the correct nozzle size that corresponds with 

the pump GPM. 

HORSEPOWER INFORMATION

We recommend that a 1.15 service factor be 

specified when selecting an electric motor as 
the power source.  To compute specific pump 

horsepower  requirements,  use  the  following 
formula:

  HP = (GPM X PSI) / 1450

   

 

LP250 HOrSEPOWEr rEQuirEMENtS

RPM GPM 1000 PSI 1500 PSI 2000 PSI 2200 PSI

500

13.0

9.0

13.5

18.0

19.8

640

16.6

11.5

17.3

23.1

25.4

750

19.5

13.5

20.3

27.1

29.8

805

20.9

14.5

21.8

29.0

31.9

865

22.5

15.6

23.4

31.2

34.3

920

23.9

16.6

24.9

33.2

36.5

1000

26.0

18.0

27.1

36.1

39.7

Содержание LP250-5100HK

Страница 1: ...Repair Instructions page 6 8 Torque Specifications page 8 Pump Mounting Selection Guide page 8 Trouble Shooting page 9 Recommended Spare Parts List page 9 Dimensions page 10 Warranty Information back...

Страница 2: ...Inc 4 Run the pump dry approximately 10 seconds to drain the water before exposure to freezing temperatures 1 Prior to initial operation add oil to the crank case so that oil level is between the two...

Страница 3: ...low for a 5 toler ance on pumps output due to variations in pul leys belts and motors among manufacturers 1 SelectGPMrequired thenselectappropriate motor and pump pulley from the same line 2 Thedesire...

Страница 4: ...4 Exploded View LP250 5100HK Pump...

Страница 5: ...SCRIPTION QTY 30 07789 Flinger 3 31 07133 Oil Seal 3 35 13024 0100 Steel Valve 3 36 13025 Grooved Ring 3 37 07170 0100 Seal Case 3 38 07140 O Ring 3 38A 12055 O Ring 3 39 13026 0100 Pressure Ring 3 40...

Страница 6: ...ing surface and replace worn parts Reassemble with new o rings 44A and oil them before installing Tighten up tension plugs 48 to 107 ft lbs 5 Loosen the 8 nuts 49A with a 19mm wrench Tap the back of t...

Страница 7: ...29D 29C 10 Place new plunger pipe 29B carefully through the oiled seals and push seal sleeve 35 with plunger pipe into the crankcase guide Note Make sure weep hole is facing down 11 Tighten the tensio...

Страница 8: ...eal 15 and o ring 16 Fit crankshaft 22 through bearing hole on the opposite side Press in outer bearing and tighten it inwards with the bearing cover keeping the crankshaft in vertical position and tu...

Страница 9: ...e hose Clean Reset and Replace worn parts Check suction lines on inlet of pump for restrictions Check for proper operation Reduce oil change interval Replace seals Replace bearings Refill crankcase oi...

Страница 10: ...10 LP250 5100HK PUMP DIMENSIONS MM INCHES...

Страница 11: ......

Страница 12: ...made by the customer or third party 6 The operation of pumps and or accessories exceeding the specifications set forth in the Operations Manuals provided by Giant Industries Inc Liability under this...

Отзывы: