background image

Volume ........................................................................................................ Up to 17.6 GPM

Discharge Pressure ..................................................................................... Up to 1200 PSI

Inlet Pressure .............................................................................................. Up to 90 PSI

Speed .......................................................................................................... Up to 570 RPM

Plunger Diameter ........................................................................................ 36 mm

Stroke .......................................................................................................... 40 mm

Crankcase Oil Capacity .............................................................................. 116 fl.oz.

Temperature of Pumped Fluids .................................................................. Up to 221 

o

F

Inlet Port ..................................................................................................... 1" BSP

Discharge Port ............................................................................................ 1-1/4" BSP

Crankshaft Mounting .................................................................................. Either Side

Shaft Rotation ................................................................................ Top of Pulley Towards Fluid End

Weight......................................................................................................... 110 lbs.

Crankshaft Diameter................................................................................... 35 mm

LP121HT PULLEY SELECTION AND HORSEPOWER 

REQUIREMENTS

RPM

GPM

300 PSI

600 PSI

900 PSI

1200 PSI

200

6.2

1.3

2.6

3.8

5.1

300

9.3

1.9

3.8

5.8

7.7

400

12.4

2.6

5.1

7.7

10.2

500

15.5

3.2

6.4

9.6

12.8

570

17.6

3.7

7.3

11.0

14.6

PULLEY INFORMATION

Pulley selection and pump speed are based on a 1725

RPM motor and "B" section belts.  When selecting

desired GPM, allow for a ±5% tolerance on pumps

output due to variations in pulleys, belts and motors

among manufacturers.

1. Select GPM required, then select appropriate

motor and pump pulley from the same line.

2. The desired pressure is achieved by selecting the

correct nozzle size that corresponds with the pump

GPM.

HORSEPOWER INFORMATION

Horsepower ratings shown are the power require-

ments for the pump.  Gas engine power outputs

must be approximately twice the pump power

requirements shown above.

We recommend that a 1.1 service factor be specified

when selecting an electric motor as the power source.

To compute specific pump horsepower requirements,

use the following formula:

(GPM X PSI)/1450 = HP

Specifications

LP121HT Pump

3

EXPLODED VIEW - LP121HT

Содержание LP121HT

Страница 1: ...View page 4 Parts List Kits page 5 Torque Specifications page 5 Operating Instructions page 6 Repair Instructions pages 7 Dimensions back page Warranty Information back page Triplex Ceramic Plunger Pu...

Страница 2: ...of a shut off gun Finally remember that high pressure operation in a pump system has many advantages But if it is used carelessly and without regard to its potential hazard it can cause serious injury...

Страница 3: ...ction and pump speed are based on a 1725 RPM motor and B section belts When selecting desired GPM allow for a 5 tolerance on pumps output due to variations in pulleys belts and motors among manufactur...

Страница 4: ...EXPLODED VIEW LP121HT PUMP 4PARTS LIST LP121HT PUMPItem Part Description Qty 1 07759 Crankcase 1...

Страница 5: ...Oil Seal 3 32 06116 Oil Seal Retainer 3 32A 06119 O Ring 3 33 06117 Backup Seal 3 35 07135 Seal Sleeve 3 36 13291 Leakage Seal 3 37 07139 Seal Case 3 38 07140 O Ring 6 39 07142 Pressure Ring 3 40 131...

Страница 6: ...by a rigid pipe Rather use a flexible hose which is not reinforced by steel that is 1 5 to 2 times wider than the inlet port If a booster pump is used the hose is to be attached between the booster pu...

Страница 7: ...nkcase cover 4 and bearing cover 14 Loosen connecting rod screws 24 and push the connecting rod plunger base assembly forward as far as possible into the crosshead guides Caution Connecting rods are m...

Страница 8: ...anges or modifications made by the customer or third party 6 The operation of pumps and or accessories exceeding the specifications set forth in the Operations Manuals provided by Giant Industries Inc...

Отзывы: