9
To Check Valves
Loosen screws (58) and lift discharge casing (50B) up and away. Take out pressure springs (57). Pull out as
-
sembled valves (51 and 52) with fitting tool (p/n 07662).
Dismantling valves:
the spring tension cap (51A, 52A) is screwed together with the valve seat (51B/52B).
Remove spring tension cap, take out springs (51E/52E) and valve plate (51C/52C). Check sealing surfaces
and O-rings (51D/F, 52D/F, 56A).
Replace worn parts.
When reassembling, coat threads of valve seat with silicon grease or molycote anti-seize Cu-7439. Before
refitting the valves, clean the sealing surfaces in the casing and check for any damage.
Tighten screws (58) at 132 Ft-lbs (180 NM); check torque tension after 8-10 operating hours.
To Check Seals and Plunger Pipe
Remove hexagon nuts (49A). Remove pump head together with seal case (38) and intermediate casing (62)
from crankcase (1). If necessary, carefully tap the valve casing (50) past the centering stud (50A) using a
rubber hammer.
Important!
If necessary, support the pump head by resting it on wooden blocks or by using a pulley.
Take off flat leakage seal (62D) and check to make sure that it is not torn or damaged.
Remove plunger (36) from crosshead with plunger base (25) and take seal sleeve (39) together with all
mounted parts out of the drive.
Pull plunger out of seal assembly and check for any damage. Clean centering and top-surface of crosshead
with plunger base (25). Take out tension spring (45). Carefully remove the whole seal unit (41-44) by using
socket wrench or the backside of a screwdriver. Check plunger surface and seals. Check O-rings (39).
Renew damaged parts.
After removing clip-ring (40C) and pressure ring (40B), check leakage seal (40) and O-ring (40A) . If neces
-
sary, replace worn parts.
Important!
Be careful not to damage seal sleeve (39), pressure ring (41) and guide ring (41A). Check the
inner diameter of the pressure ring and guide ring for wear and, if necessary, replace together with seals
(42) and support ring (44). Clean all parts. Before installation, new parts should be lightly coated with silicon
grease.
Insert the seal unit (41-45) into the seal sleeve (39). Carefully push the plunger (36) through the seals (from
the crankcase side). If necessary, the seals can be held tightly using a suitable pipe support held on the op-
posite side of the seal sleeve.
Take out the seal case (38) from the intermediate casing (62) and check O-rings (38A). If necessary, secure 2
screwdrivers in the front O-ring groove to extract seal casing from intermediate casing. Before installing, coat
O-rings with silicon grease.
Important!
Mounting surfaces of the crankcase, seal sleeves, intermediate casing and valve casing must be
clean and free of damage. The components must fit exactly and evenly on one another. The same exactness
applies for all centering positions in the crankcase, intermediate casing, pressure-and valve casing.
Coat the seal sleeve lightly with anticorrosive grease (e.g. molycote no. Cu-7439) in its fitted area towards the
crankcase. Insert seal sleeves in to their crankcase fittings.
Important!
Watch the even milled surfaces on the seal sleeves. They must be positioned vertically on each
other.
Turn the pump (by hand) until the plunger base (25) rests against the plunger (36). Tighten plunger (36) to 33
Ft-lbs. (45 NM).
Insert the seal tension spring (45) in to the seal sleeve (39).
GP8135 and GP8140 Pump Repair Instructions