background image

2

Performance data for intermittent operation, data for 

continuous operation on request.

For information on intermittent operation and 

calculating of the performance data, see the Giant 

assembly instructions.

NPSHR / Inlet pressure

Required NPSH refers to water (at 68 °F or 20 °C) at 

maximum permissible pump speed.

Maximum inlet pressure: 29 PSI (2.0 bar).

Level of noise emission

Emission sound pressure level ≤93 dB(A)

2.  Fields of application

The fields of application of these pump types 

correspond to the specifications in the assembly 

instructions of Giant pumps.

3.  Ambient conditions

Ambient temperature:    41°F (5°C)<T 

Amb.

<86°F (30 °C)

4.  Oil Filling

• 

Filling quantity: 

1.9 gallons (7.2 L)

•  Quality: 

 

Industrial gear oil 

ISO VG  

 

  220

 or automotive gear   

 

  oil 

SAE 90 GL4 or Giant’s  

 

 

 

equivalent (p/n 01154)

• 

Intervals:   

first oil change after  

 

 

 

      

50 operating hours

 

   than 

every 

500   

 

   operating 

hours

, but 

 

 

 

at the latest after 

12    

   months

5. Installation/Putting into Operation
5.1 Shaft protector

When the pump is in operation, the open shaft 

end must be covered up by shaft protector (21), 

the driven shaft side and coupling by a contact-

protector.

To cover the exposed crankshaft end, mount the 

shaft guard (21) together with the holder (21A) onto 

the bearing cover (14) and secure with bearing 

cover screws (17).

 

5.2 Direction of pump rotation

Set the direction of rotation of the drive unit 

according to the direction of rotation arrow on the 

crankcase.

5.3 Suction line filter

Recommended mesh size 50 μm.

6. Operation

Maximum operation pressure is attainable at 600 - 

800 rpm. If the speed is reduced further, the pump 

pressure must be reduced in the same proportion 

to ensure sufficient gearbox lubrication.

6.1 Discharge Line

The pump comes with two special lens seals (62) 

which have to be inserted in to the discharge ports 

of the pump. One of the two ports is to be closed 

with the included plug (63).

The 1/2” BSP high-pressure hose connection for 

the discharge line must be constructed as per the 

below drawing to ensure that together with lens 

seal (62) the discharge line is completely sealed.

We offer the high-pressure connection (05361) 

with UNF 9/16’’ female threads for high-pressure 

fittings.

The two 1/2” BSP connections on the top side of 

the valve casing are closed off with plug (60) and 

copper seal ring (61). These two connections are 

for the optional fitting of a pressure gauge and/or 

safety valve such as our 23140.

Should a pressure gauge or safety valve be 

installed, the copper ring (61) must remain in the 

bore. 

Pressure gauges with a 1/2” BSP connection have 

the appropriate contour so that the copper ring sits 

properly.

The alignment of the pressure gauge cannot be 

determined exactly after tightening.

We offer the double nipple (05362) for mounting 

the 23140 pressure relief valve.

For further information, see assembly 

instructions of Giant Pumps

Содержание GP7622

Страница 1: ...page 7 Exploded View page 8 Parts List page 9 Kits page 10 Torque Specifications page 10 Repair Instructions pages 11 14 Dimensions page 15 Warranty Information back page Triplex Ceramic Plunger Pump...

Страница 2: ...direction of rotation of the drive unit according to the direction of rotation arrow on the crankcase 5 3 Suction line filter Recommended mesh size 50 m 6 Operation Maximum operation pressure is attai...

Страница 3: ...laced before reassembling Suction Valves Remove suction valve spring 50 with valve plate 51 from seal case 38 Check sealing surfaces of the valve plate 51 and valve body 52 Check O rings 38 A B C and...

Страница 4: ...54 with the seal sleeves 38 onto the sealing sleeves 39 39A Tighten the screws 58 for fastening the valve housing evenly to the specified torque If required supplementary assembly instructions can be...

Страница 5: ...tions Model GP7622 HORSEPOWER RATINGS The rating shown are the power require ments for the pump Gas engine power outputs must be approximately twice the pump power requirements shown above We recommen...

Страница 6: ...and the high pressure connection 05361 can seize when being screwed out of the casing To release tension beforehand strike the plugs 1 2 times with a steel hammer on the top before screwing them out...

Страница 7: ...ainer 3 33B 07628 Circlip for Seal Retainer 3 33C 07249 Fitting Disc 3 34 13137 Oil Scraper Flinger 3 36 06748 Plunger 3 38 03452 Seal Sleave 3 ITEM PART DESCRIPTION QTY 38A 13286 O Ring 3 38B 07303 O...

Страница 8: ...ifications made by the customer or third party 6 The operation of pumps and or accessories exceeding the specifications set forth in the Operations Manuals provided by Giant Industries Inc Liability u...

Отзывы: