Installation of the Giant Industries, Inc.,
pump is not a complicated procedure, but
there are some basic steps common to all
pumps.  The following information is to be
considered as a general outline for installa-
tion.  If you have unique requirements, please
contact Giant Industries, Inc. or your local
distributor for assistance.

1.  The pump should be installed flat on a base
to a maximum of a 15 degree angle of inclina-
tion to ensure optimum lubrication.

2.  The inlet to the pump should be sized for the
flow rate of the pump with no unnecessary
restrictions that can cause cavitation.  Teflon
tape should be used to seal all joints.  If pumps
are to be operated at temperatures in excess of
140

0

 F, it is important to insure a positive head

to the pump to prevent cavitation.

3.  The discharge plumbing from the pump
should be properly sized to the flow rate to
prevent line pressure loss to the work area.  It is
essential to provide a safety bypass valve
between the pump and the work area to protect
the pump from pressure spikes in the event of a
blockage or the use of a shut-off gun.

4.  Use of a dampener is necessary to minimize
pulsation at drive elements, plumbing, connec-
tions, and other system areas.  The use of a
dampener with Giant Industries, Inc. pumps is
optional, although recommended by Giant

INSTALLATION INSTRUCTIONS

2.  Pump operation must not exceed rated
pressure, volume, or RPM.  A pressure relief
device must be installed in the discharge of
the system.

3.  Acids, alkalines, or abrasive fluids cannot
be pumped unless approval in writing is
obtained before operation from Giant Indus-
tries, Inc.

4.  Run the pump dry approximately 10
seconds to drain the water before exposure to
freezing temperatures.

1.  Prior to initial operation, add oil to crank-
case so that oil level is between the two lines on
the oil dipstick.  DO NOT OVERFILL.  SAE 80
or SAE 90 Industrial Gear (p/n 01154) oil
may be used
.  Crankcase oil should be changed
after the first 50 hours of operation, then at
regular intervals of 500 hours or less depending
on operating conditions.

NOTE:  Contact Giant Industries for Service School Information.  Phone: (419)-531-4600

Industries, Inc. to further reduce system pulsa-
tion.  Dampeners can also reduce the severity
of pressure spikes that occur in systems using a
shut-off gun.  A dampener must be positioned
downstream from the unloader.
5.  Crankshaft rotation on Giant Industries, Inc.
pumps should be made in the direction desig-
nated by the arrows on the pump crankcase.
Reverse rotation may be safely achieved by
following a few guidelines available upon
request from Giant Industries, Inc.  Required
horsepower for system operation can be ob-
tained from the charts on pages 3-4.

6.  Before beginning operation of your pump-
ing system, remember:  Check that the crank-
case and seal areas have been properly lubri-
cated per recommended schedules.  Do not run
the pump dry for extended periods of time.
Cavitation will result in severe damage.  Al-
ways remember to check that all plumbing
valves are open and that pumped media can
flow freely to the inlet of the pump.

Finally, remember that high pressure opera-
tion in a pump system has many advantages.
But, if it is used carelessly and without regard
to its potential hazard, it can cause serious
injury.

IMPORTANT OPERATING

CONDITIONS

Failure to comply with any of these

conditions invalidates the warranty

2

Содержание GP5136-5100

Страница 1: ...Torque Specs page 5 Recommended Maintenance page 5 Exploded View Parts List pages 6 7 Trouble Shooting page 8 Repair Instructions pages 9 10 Dimensions page 11 WarrantyInformation back page Models GP5136 5100 GP5145 5100 Triplex Ceramic Plunger Pump OperatingInstructions Manual ...

Страница 2: ...m Giant Indus tries Inc 4 Run the pump dry approximately 10 seconds to drain the water before exposure to freezing temperatures 1 Prior to initial operation add oil to crank case so that oil level is between the two lines on the oil dipstick DO NOT OVERFILL SAE 80 or SAE 90 Industrial Gear p n 01154 oil may be used Crankcase oil should be changed after the first 50 hours of operation then at regul...

Страница 3: ...mp horsepower requirements use the follow ing formula HP GPM X PSI 1450 3 RPM GPM 1000 PSI 1500 PSI 2000 PSI 2320 700 26 0 17 9 26 9 35 9 41 6 750 27 9 19 2 28 8 38 4 44 6 800 29 7 20 5 30 7 41 0 47 5 850 31 6 21 8 32 7 43 5 50 5 910 33 8 23 3 35 0 46 6 54 1 GP5136 5100 Horsepower Requirements Volume 33 8 GPM 127 8 LPM Discharge Pressure 2320 PSI 160 Bar Crankshaft Speed 910 RPM Inlet Pressure 4 3...

Страница 4: ...or the pump Gas engine power outputs must be approximately twice the pump power requirements shown above SPECIAL NOTE FOR CONTINUAL OPERATION THE SPEED OF THE PUMP MUST BE LIMITED TO 700 RPM AND THE MAXIMUM PRESSURE OF THE PUMP MUST BE REDUCED BY 10 Consult the factory for special requirements that must be met if the pump is to operate beyond one or more of the limits specified above We recommend ...

Страница 5: ...d GP5145 5100 Pumps Repair Kits Valve Assembly Kits Inlet Valve Kit p n 09231 0100 Item Part Description Qty 46A 12055 O Ring 1 46C 13304 0100 Inlet Valve Assy 1 46D 13306 0100 Valve Plate 1 46E 13307 Valve Spring 1 46F 13308 Spring Tension Cap 1 46G 13309 Spacer Pipe 1 48B 07740 O Ring 1 Discharge Valve Kit p n 09232 0100 Item Part Description Qty 47A 13289 O Ring 1 47C 13313 Discharge Valve Assy...

Страница 6: ...Exploded View GP5136 5100 and GP5145 5100 Pumps 6 55 ...

Страница 7: ... 06574 0100 Seal Case GP5136 5100 3 37 06145 0100 Pressure Ring Drip Return GP5145 5100 3 GP5136 5100 and GP5145 5100 Pumps Spare PARTS LIST ITEMPART DESCRIPTION QTY 37A 07910 O Ring GP5136 5100 Only 6 39 07142 0100 Pressure Ring GP5136 5100 3 39 13292 Pressure Ring GP5145 5100 3 40 07144 V Sleeve GP5136 5100 6 40 13294 Sleeve GP5145 5100 6 40A 06146 Grooved Ring GP5145 5100 Only 3 41 07146 0100 S...

Страница 8: ...on Check system for stoppage air leaks correctly sized inlet plumbing to pump Accumulator pressure Recharge or replace accumulator Unloader Check for proper operation Cavitation Check inlet lines for restrictions and or proper sizing Pressure drop at gun Restricted discharge plumbing Re size discharge plumbing to flow rate of pump Worn plungers Replace plungers Worn packing seals Adjust or replace...

Страница 9: ...ws 48A to 35 ft lbs To Check Seals and Plunger Pipes 1 Loosen the eight inner hexagon screws 49 and pull of the valve casing 43 to the front Pull seal sleeves 35 out of the guides in the crankcase and over the plunger pipes 29B Remove sleeve support ring 41 sleeves 40 and grooved rings GP5136 5100 only 36 Replace worn parts as necessary 2 If a plunger pipe 29B is worn out loosen the tension screw ...

Страница 10: ...crosshead assemblies 25 as well as the radial shaft seals 15 and 31 and taper roller bearings 20 To Reassemble Gear End 1 Using a soft tool such as brass or wooden dowel press in the outer bearing ring until it lines up with the outer edge of the bearing hole Assemble the bearing cover 14 together with the shaft seal 15 and o ring 16 2 Fit the crankshaft 22 with pressed on bearing parts through th...

Страница 11: ...Pump Dimensions GP5136 5100 and GP5145 5100 Pumps Inches mm 11 ...

Страница 12: ...to standard wear parts 3 Use of repair parts other than those manufactured or authorized by Giant 4 Improper use of the product as a component part 5 Changes or modifications made by the customer or third party 6 The operation of pumps and or accessories exceeding the specifications set forth in the Operations Manuals provided by Giant Industries Inc Liability under this warranty is on all non wea...

Отзывы: