background image

Electromagnetic Lock Installation Instruction

Connecting Diagram

SPDT relay

3A/12VDC

Power

Input

N.C.

COM.

N.O.

-

+

-

+

12VDC

24VDC

PH-450/ PH-900

 

 Handle Lock Series

We b s i t e :   w w w. g i a n n i . c o m . t w    
E - m a i l :   i n f o @ g i a n n i . c o m . t w

Zinc plated

Current Draw 

Technical Specification

Operating Voltage

(at temperature 20ºC)

Operating Temperature

Relay Rating

Holding Force

Lock Surface Temperature

 ambient temperature ±20˚C

PH-450: 600 lbs 

Special Finishes for magnet
and armature plate

Trigger

Relocking timer
(PH-450MTD)

The door will lock automatically after the
circuit trigger connects to each other. VR
timer adjustable up to 30 seconds.

Magnet bond

sensor output

(PH-450M)

Power

supply

N.C. contact of control
Device / Access Relay

Timer Adjustment

Shorten

Voltage Selection Jumpers
C h e c k   j u m p e r   s e t t i n g s   b e f o r e
connecting the lock to input power.
Incorrect jumper settings may cause
or result in damage of the lock.

Lock & unlock status

Notice that PH-450/PH-900 series

 of  maglocks should be installed

 on “inswing” doors and frames 

for the sake of security.

Installing the maglock on outswing 

doors/frames will pose security 

problems.

Inswing

Outswi

ng

Armature Plate

Rubber Washer

Upper Case

Handle

Trimming plate

Fixing Screw

Bottom case

Armature Assembly

Magnet Assembly

Tamper Screw

Electromagnetic Lock

Tool Kit

Blind Nuts

Tool

Dimensions & Accessories

Inswing

-10~55°C(14~131°F)

3A/12VDC

250mA/24VDC

PH450:12/24VDC
PH900:12/24VDC x2

PH450:500mA/12VDC

250mA/24VDC x2

PH900:500mA/12VDC x2

Specification

PH-900: 600 lbs x2

(approx. 272 kg x2)

(approx. 272 kg)

Отзывы: