Auxiliary reader

  The auxiliary reader must not be further than 50 meters from 
the  DG-600H.  Also  this  reader  should  be  nearer  than  60 
centimeters, to avoid disturbance. The suggested wire gauge 
is  #22~26  AWG. 

auxiliary 

Split  of  units  for  DG-600H  and 

reader    in  ranging  up  to  50  M  bring  out  the  friendly  system 
device  for  low  cost  but  high  security  with  anti-tampering  as 
well as convenience and reliability.

DG-600H 
Stand-alone Proximity Reader 

Connecting Diagram

 

 

 

 

 

 

Fail-Safe Lock
St 2 connect to 1-2

Contact door switch or the 

electric lock signal output

Push Button

External relay start

the warning system

Auxiliary Reader

(Wiegand Format)

Connect to 1-2;C and D contact is N.C. 
Connect to 2-3; for N.O. 

Connect to 1-2;C and A contact is N.C. 
Connect to 2-3; for N.O. 

Fail-Secure Lock
St 2 connect to 2-3

*Linear supply recommended 

 Power supply

(9~16Vdc)

 Insert 2-3 position to reset

GEMPROX-H

125 KHz,Wiegand 26~37-bit 
format output
Size:88(L) X 44(W)X16(D)mm

 

 DG-600H Jp1 leads to all Wiegand format

 DG-600H Jp1 short-circuit to Wiegand 26 bits format