DG-5 The Digital Keyless Entry System
Operation User's Manual
1. Features:
4 digit codes
(
5 digit codes available by special order
)
Tamper Switch Included
Door Reed Switch Input for Anti-Trailing
10 user PINs
Fully Programmable via keypad and master code
Non-Volatile
Memory
Invalid PIN Lock-out
2. Specifications:
Operating Voltage: 9~14 Vdc
Current Draw: Average 20mA, Peak 70mA @ 12Vdc
Input: One request-to-exit, and time out reed switch
Relays: N.O./N.C./Com. Output (free voltage contact),
3A@ 125Vac or 30Vdc
Case Material: ABS
(
UL94V0
)
Operating
Temperature:-20~+70
℃
Ambient Humidity:0~95% relative humidity non-
condensing
Visual
Signals:
Green: Power on
Red: Relay activated
Yellow: Program Mode
、
Lock-out
Factory Master Code: 1234
Invalid PIN Lockout: System will shut down 60 seconds while 6 times of incorrectly
password attempted.
Relay Activation Time:
(*
20
)
Pulse
mode
:
1~99 seconds
(
01~99
)
Latching
mode
(
00
)
EPROM: Non-volatile memory, System will retain all programs and codes after a total
loss of power.
User
PINs:
(*
01~
*
10
)
It is possible to program 10 different user PIN codes.
3. Program
Instruction:
Enter Program Mode:
1. Enter the master code twice (Factory master is
「
1234
」
)
→
2 beeps and the Yellow LED will light up.
→
you are now in the "programming mode".
2.
Note:
After 60 seconds if you have not entered any codes or data, the system will
automatically exit from the programming mode. After 6 wrong attempts at the master
code the lockout facility will operate.
Exiting from the program mode:
1. Press
「
#
」
to exit from the programming mode.
Copyright Gianni Industries, Inc. All Rights Reserved.
PMUDG5 Ver. B Publish:2009.06.15 Page: 1/ 3