E
xample 3.
Use this way in balcony or semi-enclosed space can charge cool and fresh air into room. Inlet
air
from
outdoor without duct, outlet air ducted to room. Air
outlet
duct length
≤
6m.
4. Installation/Usage Requirements (Please refer to the installation diagrams)
●
The appliance should be placed horizontal, and water pipes, water filter, electricity guards and
one-way safety valve should be installed in accordance with the national standards.
●
Water injection: Turn on one of the water outlet and water inlet valve. It means injection finished
when there is water comes out of the outlet. You can switch on the heater after that.
●
The water quality should meet the following standards: Hardness (CaCO3)
≤
200mg/L, Chloride
ions
≤
50mg/L, PH value 6.5~8.5, and you should clean the inner water tank regularly.
Fig.6
Fig.7
-7-
F9: the status of photovoltaic function; 0 means the function off, 1 means the function on. You
can change the status by pressing “CLOCK” button and save the status by pressing “MODE”
button. The factory setting for this function is on.
FA: return difference value of water temperature. The factory setting is 5
℃
.
Note:
user can not
change this
, otherwise it will affect the appliance’s performance.
(6) When under "Automatic", "Heat pump" or “Boost” mode, the compressor has 3-minute starting
delay protection function.
(7) In order to avoid starting frequently, when it reaches the setting temperature and stops, the
appliance will not restart until when the water temperature is 5
℃
lower than the setting
temperature.
3. Temperature Setting of Water Tank
When the appliance is on, you can adjust the setting water temperature by pressing
▲
or
▼
button,
which makes the temperature increasing or decreasing by 1
℃
.
The water temperature is set to 53
℃
at the factory.
4. Clock Setting
In the home page, long press the “CLOCK” button for at least 3 seconds to enter the clock setting
status. You can choose the data you want to adjust by pressing the “TIMING” button, and
"minutes" and “hours” will flash in the time zone by turns. You can adjust the current data by
pressing
▲
or
▼
button. Press the “MODE” button and the clock setting is saved.
In the process of setting clock, if you don't operate any buttons for more than 35 seconds, then
the setting will automatically exit and the clock will not be saved.
5. Timing Function
In the home page, press the “TIMING” button, then it will enter the timing setting status. The
setting order is as follow: the first timing
→
the second timing
→
the third timing
→
finish. For each
timing setting, it is required to set the turn-on time first (the timing indicator will be on).
During the setting, press the “TIMING” button to choose the data you want to adjust, and it will
show on the display as hours
→
minutes
→
temperature
→
hours. You can adjust the glittery data on
the display by pressing
▲
or
▼
button. Press the “MODE” button to set the turn-off time and
temperature (the tim
ing
indicator will be off). Press the “MODE” button one more time to save the
first timing and begin to set the next timing.
If you long press the “MODE” button for at least 3 seconds during the setting, the current timing
will not be saved and it will go back to the home page. For example, if you just want to set the first
timing, you should do the above operation during the second timing setting.
6. Delete the Timing Records
Enter the timing setting status, long press the “TIMING” button for at least 3 seconds, all the
timing records will be deleted and it will go back to the home page.
7. Trace the Timing Records
Activate the display and press the “TIMING” button, enter the status to trace the timing records.
Press “MODE” button to change over different records.
Kindly reminder:
◇
You can select the time slot from 12 a.m. to 5 p.m. as the running time to heat the water,
because the ambient temperature will be higher and can absorb more heat, which guarantees
good working efficiency.
◇
It is suggested to choose off-peak period to operate the appliance, because most of the regions
have cheaper electric charge at off-peak period.
parameter
Instructions of Usage and Daily Operations
Installation
43
Содержание HTW HTW-AT-O-200VA2
Страница 2: ......
Страница 3: ...MANUAL DE USUARIO E INSTALACIÓN ESPAÑOL VA2 HTW AT O 200VA2 HTW ATS O 200VA2 Acumulador aerotérmico ...
Страница 29: ...VA2 OWNER S AND INSTALLATION MANUAL ENGLISH Sanitary water heat pump HTW AT O 200VA2 HTW ATS O 200VA2 ...
Страница 30: ...25 ...
Страница 56: ...51 ...
Страница 58: ...53 ...
Страница 84: ...79 ...
Страница 86: ...81 ...
Страница 112: ...107 ...
Страница 113: ...VA2 ITALIANO MANUALE DI UTENTE E INSTALLAZIONE Accumulatori aerotermici HTW AT O 200VA2 HTW ATS O 200VA2 ...