17. Decommissioning
Before carrying out this procedure, it is essential that the technician is completely familiar
with the equipment and all its detail. It is recommended good practice that all refrigerants
are recovered safely. Prior to the task being carried out, an oil and refrigerant sample shall
be taken.
In case analysis is required prior to re-use of reclaimed refrigerant. It is essential that
electrical power is available before the task is commenced.
a) Become familiar with the equipment and its operation.
b) Isolate system electrically
c) Before attempting the procedure ensure that:
mechanical handling equipment is available, if required, for handling refrigerant cylinders;
all personal protetive equipment is available and being used correctly;
the recovery process is supervised at all times by a competent person;
recovery equipment and cylinders conform to the appropriate standards.
d) Pump down refrigerant system, if possible.
e) If a vacuum is not possible, make a manifold so that refrigerant can be removed from
various parts of the system.
f) Make sure that cylinder is situated on the scales before recovery takes place.
g) Start the recovery machine and operate in accordance with manufacturer s instructions.
h) Do not overfill cylinders. (No more than 80% volume liquid charge).
i) Do not exceed the maximum working pressure of the cylinder, even temporarily.
j) When the cylinders have been filled correctly and the process completed, make sure that
the cylinders and the equipment are removed from site promptly and all isolation valves
on the equipment are closed off.
k) Recovered refrigerant shall not be charged into another refrigeration system unless it has
been cleaned and checked.
16. Charging procedures
In addition to conventional charging procedures, the following requirements shall be followed:
Ensure that contamination of different refrigerants does not occur when using charging
equipment. Hoses or lines shall be as short as possible to minimize the amount of
refrigerant contained in them.
Cylinders shall be kept upright.
Ensure that the refrigeration system is earthed prior to charging the system with refrigerant.
Label the system when charging is complete(if not already).
Extreme care shall be taken not to overfill the refrigeration system.
Prior to recharging the system it shall be pressure tested with OFN. The system shall be
leak tested on completion of charging but prior to commissioning. A follow up leak test
shall be carried out prior to leaving the site.
,
When the final OFN charge is used, the system shall be vented down to atmospheric pressure
to enable work to take place. This operation is absolutely vital if brazing operations on the
pipe-work are to take place.
Ensure that the outlet for the vacuum pump is not closed to any ignition sources and there
is ventilation available.
67
Содержание Emelson IST3
Страница 2: ......
Страница 4: ......
Страница 24: ...Modelo A Modelo B Modelo A Modelo B Modelo C Modelo D Modelo E Modelo F Modelos uno cinco Modelos uno cuatro 22...
Страница 36: ......
Страница 38: ......
Страница 72: ......
Страница 96: ......
Страница 114: ..._ 1 _ f I l _ i 1 _ _ r MODELO 1X4 1010 5 kW 112...
Страница 122: ......
Страница 123: ...IST3 ITALIANO MANUALE DI INSTALLAZIONE MULTISPLIT EML3M28S9912IST3W EML3M21S9912IST3W EML2M14S912IST3W EML2M14S99IST3W...
Страница 124: ...122...
Страница 125: ...123 124 126 128 129 130 132 140 145 153 158 160 162...
Страница 126: ...124...
Страница 127: ...125...
Страница 128: ...126...
Страница 129: ...127...
Страница 130: ...128...
Страница 131: ...129...
Страница 132: ...130...
Страница 133: ...131...
Страница 134: ...132...
Страница 135: ...133...
Страница 136: ...134...
Страница 137: ...135...
Страница 138: ...136...
Страница 139: ...137...
Страница 140: ...138...
Страница 141: ...139...
Страница 142: ...140...
Страница 143: ...141...
Страница 144: ...142...
Страница 145: ...143...
Страница 146: ...144...
Страница 147: ...145...
Страница 148: ...146...
Страница 149: ...147...
Страница 150: ...148...
Страница 151: ...149...
Страница 152: ...150...
Страница 153: ...151...
Страница 154: ...152...
Страница 155: ...153...
Страница 156: ...154...
Страница 157: ...155...
Страница 158: ...156...
Страница 159: ...157...
Страница 160: ...158...
Страница 161: ...159...
Страница 162: ...160...
Страница 163: ...161...
Страница 164: ...162...
Страница 165: ......
Страница 166: ......
Страница 167: ......