SC24
WARNING!
A programming of the function different from the configuration pre-set by the
manufacturer, although it allows, if correctly done, the reduction of the cases of stop of
the system in intermediate position (as a simply example, for the presence of frictions,
wind and/or obstacles on the way of the movable element), causes, in any case, a
reduction of the safety level of the same system and a consequent danger for people
safety.
10 - DIP SWITCH SW4
The settings are stored during the rest phase (gate closed).
The DEFAULT settings are coloured in grey
DIP 2
-
-
ON
OFF
--
Description
DIP
Status
Function
DIP 1
Enables the function attempts after the intervention of the safety devices.
After the intervention of the safety device SAFETY or SAFETY-STOP (DIP 10 = ON) or
of the ANTI CRUSHING and, after 10 seconds, the automation will try, for 3 times
max., to restart the motion in the direction that has been interrupted.
After another intervention of the safety device, the automation stops waiting for some
commands.
ON
ATTEMPTS AFTER
SAFETY DEVICES
INTERVENTION
OFF
Disables the function.
11 - TRIMMER ADJUSTMENT
UK
15
Trimmer
PAUSE
FORCE
SLOW
Descrizione
Default
AMP.
SLOW
AMP.
FORCE
Adjusts the PAUSE TIME from 2 to 250 seconds. The value is increased by turning the trimmer
clockwise.
Adjusts the intervention sensitivity of the anti crushing during the decelerated movement period.
Turning the trimmer clockwise, the sensitivity decreases.
Adjusts the motor FORCE/SPEED during the decelerated movement period.
Adjusts the intervention sensitivity of the anti crushing during the not decelerated movement period.
Turning the trimmer clockwise, the sensitivity decreases.
Adjusts the motor FORCE/SPEED during the decelerated movement period.