SC24
Description
DIP 1
DIP 2
DIP
OFF
OFF
Status
Function
STEP–BY-STEP
WITH STOP
8 - DIP SWITCH SW1
The settings are stored during the rest phase (gate closed).
OFF
ON
CONDOMINIUM
ON
OFF
STEP–BY-STEP
DIP 3
If Start button is held down:
OPENS
If Pedestrian button is held down:
CLOSES
The SAFETY 8K2, PHOTO inputs and the decelerations will not be active.
STOP 8K2 will be enabled.
Not manageable with radio control.
Enables the pre-flashing of 3 seconds before the activation of the motor in opening and
closing.
Disables the pre-flashing.
ON
ON
ON
OFF
DEAD MAN
PRE-FLASHING
Operation in reply to a START command:
Gate closed
OPENS
→
During opening
STOPS
→
Gate open
CLOSES
→
During closing
STOPS
→
After a STOP
inverts the motion
→
Operation in reply to a START command:
Gate closed
OPENS
→
During opening
CLOSES
→
Gate open
CLOSES
→
During closing
OPENS
→
Operation in reply to a START command:
Gate closed
OPENS
→
During opening
IRRELEVANT
→
Gate open
Recharges the automatic closing time if the automatic
→
reclosing is enabled, otherwise closes.
During closing
OPENS
→
The DEFAULT settings are coloured in grey
6 - ELECTRICAL CONNECTIONS: FASTON
7 - PROTECTION FUSES
UK
13
0 Vac
18 Vac
24 Vac
Faston
Description
Transformer 0 Vac connection (black cable).
Transformer 18 Vac connection (orange cable).
Transformer 24 Vac connection (red cable).
Protects the ACCESSORY and SAFETY DEVICE power supply.
315 mA
FAST-BLOW
Protects the control unit at the 24 VAC power supply input.
Protects the flashlight output.
5 A
500 mA
FAST-BLOW
FAST-BLOW
F1
F2
F3
Description
Position
Value
Type
Содержание GI.BI.DI SC24
Страница 18: ...SC24 NOTE 18...
Страница 19: ...SC24 NOTE 19...