background image

Questions, problems, missing parts? Before returning to your retailer, call our customer

service department at 877-447-4768

  

8:30 a.m. –  4:30

 

pm CST, Monday – Friday

or email us at [email protected]

 

USER’S MANUAL AND OPERATING INSTRUCTIONS

C           US

MODEL # RA18LPDG, RA18LPDGD, 

RA18LPDGP, RA18LPA, RA18LPB, and RA18LPC

 

PROPANE CONSTRUCTION HEATER

CONSUMER:

 Retain this manual for future reference.

Dyna-Glo, Dyna-Glo Pro

Dyna-Glo Delux

IMPORTANT: 

Read and undeRSTand 

ThiS Manual BeFoRe aSSeMBling, 
STaRTing oR SeRviCing heaTeR. 
iMpRopeR uSe oF heaTeR Can 
CauSe SeRiouS injuRy. Keep ThiS 
Manual FoR FuTuRe ReFeRenCe.

GENERAL HAZARD WARNING:

 

    FailuRe To CoMply wiTh The 

pReCauTionS and inSTRuCTionS pRovided 

wiTh ThiS heaTeR, Can ReSulT in deaTh, 

SeRiouS Bodily injuRy and pRopeRTy 

loSS, oR daMage FRoM The hazaRdS oF 

FiRe, exploSion, BuRn. aSphyxiaTion, 

CaRBon Monoxide poiSoning, and/oR 

eleCTRiCal ShoCK. 

only peRSonS who Can undeRSTand and 

Follow The inSTRuCTionS Should uSe oR 

SeRviCe ThiS heaTeR.

iF you need aSSiSTanCe oR heaTeR 

inFoRMaTion SuCh aS an inSTRuCTion 

Manual, laBelS, eTCeTeRa, ConTaCT The 

ManuFaCTuReR.

CALIFORNIA PROPOSITION 65 WARNING:

Fuels used in gas or oil fired appliances 

and the products of combustion of such 

fuels, contain chemicals known to the 

State of California to cause cancer, birth 

defects or other reproductive harm. This 

product contains chemicals, including 

lead and lead compounds, known to the 

state of California to cause cancer, birth 

defects or other reproductive harm.

20-10-090 

 

 

 

 

Printed in China  

Rev. 2012-03-08

ANS Z83.7-2011 CSA 2.14-2011

adequate ventilation must be provided.

Содержание Dyna-Glo Pro RA18LPDGP

Страница 1: ...th this heater can result in death serious bodily injury and property loss or damage from the hazards of fire explosion burn asphyxiation carbon monoxide poisoning and or electrical shock Only persons who can understand and follow the instructions should use or service this heater If you need assistance or heater information such as an instruction manual labels etcetera contact the manufacturer CA...

Страница 2: ... VEHICLE USE WARNING FIRE BURN INHALATION AND EXPLOSION HAZARD KEEP SOLID COMBUSTIBLES SUCH AS BUILDING MATERIALS PAPER OR CARDBOARD A SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED BY THE INSTRUCTIONS NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES OR PRODUCTS SUCH AS GASOLINE SOLVENTS PAINT THINNERS DUST PARTICLES OR UNKNOWN CHEMICALS PROPANE CONSTRUCT...

Страница 3: ...st particles or unknown chemicals WARNING If the information in this manual is not followed exactly a fire OR Explosion may result causing property damage personal injury or loss of life WARNING a Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance a An LP cylinder not connected for use shall not be stored in the vicinity of this or any...

Страница 4: ...minimum and maximum inlet pressures to the regulator from the gas tank are 5 psi and bottle pressure respectively Use only the regulator hose assembly provided with the heater Inspect the regulator hose assembly prior to each use of the heater If there is excessive abrasion or wear or hose is cut replace with regulator hose assembly listed on the parts list prior to using this heater Gas supply co...

Страница 5: ...Vapor Only PRODUCT FEATURES PROPANE CONSTRUCTION HEATER Size Assembled High Medium Low Maximum Minimum lbs hr kg hr L X W X H RA18 Series 18 000 12 000 6 000 Bottle Pressure 5psi 11 0 WC 0 83 0 28 0 377 0 127 16 8 lbs 7 6 kg 15 75 x14 96 x23 35 400x380x593mm Weight Input Rating BTU Hr Manifold Pressure Gas Consumption Supply Pressure Model Locking Front Caster Rear Caster Back Cover Handle Slot Sa...

Страница 6: ...er on each of the threaded portions of the caster see Figure 1 9 Thread the casters into the four threaded holes in the base of the unit by turning them clockwise The locking casters should be placed at the front of the unit and the other two at the back of the unit See Figure 1 10 Tighten The casters using the wrench supplied with the casters 11 Install 20 lb propane cylinder see Propane Supply s...

Страница 7: ...id knocking the cylinder over on its side with the hose regulator connected as this can cause damage to the regulator diaphragm Never store a propane LP cylinder indoors or in the vicinity of any gas burning appliances Protect the cylinder valve and handle it with care Be sure that the shut off valve is closed tightly after each use Be sure to protect the POL fitting from damage when disconnected ...

Страница 8: ...outlet Turn the fitting counterclockwise into the threads of the cylinder valve Some models have a hand wheel that can be slid off the nut so that a wrench can be used to tighten the fitting if desired CAUTIONPosition the regulator such that the side with the tower is facing down and the flat side is facing up See Figure 2 WARNINGEnsure that the gas hose is not touching the unpainted heat shield a...

Страница 9: ...cted from the propane tank Never store a Propane gas tank inside a building or in the vicinity of any gas burning appliance THE DISCONNECTED TANK MUST NEVER BE STORED IN A BUILDING GARAGE OR ANY OTHER ENCLOSED AREA CHECKING FOR LEAKS Check all gas connections with a soap solution to be sure they are tight and leak proof Soap bubbles indicate gas leakage that must be corrected The installation of y...

Страница 10: ...depress for 5 seconds B Note The first time that the heater is operated after connecting the gas supply the control knob should be depressed for at least 30 seconds This will allow air to bleed from the gas system 6 Depress control knob while depressing the piezo ignitor button This should cause the spark from the piezo ignitor to light the pilot gas Keep control knob depressed thirtry 30 seconds ...

Страница 11: ...ldren If for any reason the heater is to be stored indoors the tank must be disconnected and stored outdoors in a well ventilated area out of reach of children in accordance with the standard for the the Storage and Handling of Liquefied Petroleum Gases ANSI NFPA 58 and CSA B149 1 Natural Gas and Propane Installation Code The plastic tank valve plug supplied with your tank must be tightly installe...

Страница 12: ...rect Note Do not mistake orange flames with yellow tipping Dirt or dust particles may enter the burner flames and cause transient patches of orange flame Burner and ODS Pilot Cleaning Clean the exterior with soft bristle brush vacuum cleaner or pressurized air Never use a wooden toothpick as it may break off and clog the ODS pilot or main burner port Use a flashlight to inspect the main burner inl...

Страница 13: ...te repeat ignition operation 3 Contact your gas company gas supplier or qualified service technician 4 Replace thermocouple 5 Hand tight until snug then tighten 1 4 turn with a wrench 6 Replace gas control Burner does not light after ODS pilot is lit 1 Burner orifice clogged 2 Gas supply pressure is very low 1 Clean burner orifice 2 Contact gas supplier Delayed ignition 1 Main burner carry over po...

Страница 14: ...odor during combustion 1 Foreign matter in gas or on burner ports 2 Heater burning vapors form paint impurities in air 3 Gas leaks refer to front page Warnings 1 Check gas passage way and burner 2 Ventilate room stop storing and using odor causing products near heater 3 Locate and correct leaks immediately Heater shuts off on ODS 1 Not enough fresh air is available 2 Low gas pressure 3 ODS pilot p...

Страница 15: ...11B 2 13 Rear Chassis PT N11B 4 5 ODS Assembly PT N11B 6 14 Castor With Lock PT N06 33 6 Burner Assembly PT N11B 4 15 Castor Without Lock PT N06 32 7 Gas Valve PT N11B 13 16 Heat Insulation Board PT N11 6 8 Piezo Ignitor PT N11B 5 17 Back Cover PT N11B 2 1 9 Knob Base PT N11B 10 18 Knob PT N06 24 Item Model Number Part No Item Model Number Part No RA18 SERIES WARNING This heater is not intended fo...

Страница 16: ... and Hose Assembly 7 Gas Valve 6 Burner Assembly 2 Guard Assembly 11 Gas Pipe 14 Caster With Lock 10 Tilt Switch 15 Caster Without Lock 16 Heat Insulation Board 8 Piezo Ignitor 9 Knob Base 4 Reflector 1 Lower Shield 3 Front Panel EXPLODED PARTS DRAWING 5 ODS Assembly 18 Knob ...

Страница 17: ... how long an implied warranty lasts so the above limitation may not apply to you Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you CLAIMS HANDLED AS FOLLOWS 1 Contact your retailer and explain the problem 2 If the retailer is unable to resolve the problem contact ourCustomer Service Dept detailing t...

Страница 18: ...entire serial number Retain this portion of the card for your records SAVE THIS CARD Place Postage Stamp Here GHP Group Inc 8280 Austin Avenue Morton Grove IL 60053 3207 GHP Group Inc 8280 Austin Ave Morton Grove IL 60053 3207 Tel 877 447 4768 www ghpgroupinc com 8280 Austin Avenue Morton Grove IL 6 0 0 5 3 3 2 0 7 Tel 847 324 5900 Fax 847 324 5901 Toll Free 877 GHP Group 8 7 7 4 4 7 4 7 6 8 www g...

Отзывы: