WHAT IS INCLUDED IN YOUR AXUR KIT:

SPECIFICATIONS:

NOTE: The receiver is designed to allow the use of Ghost Controls

®

 Wireless accessories, such as our transmitters and keypad to 

work with other opener and operator systems that accept dry contact inputs to control the system (ex. doorbell button).
THE RECEIVER HAS TWO SOLID STATE RELAY OUTPUTS:

 

CYCLE (blue and green wires)

: This is a momentary/pulsed output. The relay is turned on momentarily for about half second 

then turns off upon receiving a valid “cycle” command from a Ghost Controls

®

 wireless device. It is to be connected to the input of 

the opener system that can open, close and stop the gate or access control system.

  

 

FREE-EXIT/OPEN (white and green wires)

: This is a latching, toggle ON/OFF output. The relay is toggle ON/OFF upon 

receiving a valid “open” command, such as “PartyMode

®

, from a Ghost Controls

®

 wireless device. It is to be connected to the input 

of the opener system that when activated will keep it OPEN.

POWER INPUT: 9-24 VDC or VAC, 15 mA
OUTPUTS: 

Solid state relay’s Max. 24VAC/DC @ 100mA max load

EXTENDABLE ANTENNA USING STANDARD COAX CABLE WITH COAX CABLE COUPLER
WEATHER RESISTANT FOR OUTDOOR INSTALLATION

DETERMINING YOUR SYSTEM REQUIREMENTS:

NOTE: Refer to your system instruction manual for details.

 

Locate and make sure that it has 9-24VAC or VDC power supply available. Typical 

system will have either 12 or 24V available. The RED WIRE of the receiver will be 

connected to the positive terminal of the power supply and the BLACK WIRE of  

the receiver will be connected to the negative terminal of the power supply.

 

Locate the input that controls its movement (open, close, and stop). Typically, a  

momentary activation with a jumper wire would “CYCLE” the opener/operator  

to each movement (open, stop, close, stop, open...). Usually, it is labeled  

“CYCLE”,  “Pushbutton” or something similar. The BLUE WIRE from the receiver 

will be connected to this input and the GREEN WIRE is connected to the COM 

or COMMON terminals.

 

Locate the input that when activated (shorted to COMMON) will keep the gate  

or access control system open. When the terminal is shorted to COMMON 

the gate or access control system cannot be closed. Usually, it is labeled “open”, 

“free-exit”, “fire-department” or something similar. The WHITE WIRE from the 

receiver will be connected to this input and the GREEN WIRE is connected to 

COM or COMMON. 

NOTE:

 Using this input is optional, this input allows the  use 

of Ghost Controls

®

 PartyMode

®

 and open-only wireless devices. 

AXUR UNIVERSAL RECEIVER

    INSTRUCTIONS                                     

RED = POSITIVE POWER SUPPLY

TEST: 

red and black wires to 

make sure getting enough 

power supply of 9-24v

WIRELESS KEYPAD

RECEIVER

5 BUTTON TRANSMITTER

BLK = NEGATIVE POWER SUPPLY

BLUE = CYCLE INPUT

GREEN = COM OR COMMON

WHITE = OPEN INPUT

Содержание AXUR

Страница 1: ... make sure that it has 9 24VAC or VDC power supply available Typical system will have either 12 or 24V available The RED WIRE of the receiver will be connected to the positive terminal of the power supply and the BLACK WIRE of the receiver will be connected to the negative terminal of the power supply Locate the input that controls its movement open close and stop Typically a momentary activation ...

Страница 2: ...OT run AC wiring through the conduit Receiver range varies depending on external interference weather and topography of the area you live in DRILL HOLE IN POST AND MOUNT RECEIVER ANTENNA FACING UP WITH THE INCLUDED SCREW PROGRAMMING THE RECEIVER WARNING The operator opener may move during programming Stay clear of its moving path REMOVE RECEIVER COVER BY UNSCREWING THE 4 SCREWS ON THE FRONT COVER ...

Страница 3: ...d the or button on the GHOST CONTROLS remote transmitter until you hear a beep and the RED LED on the receiver turns off The transmitter is now programmed into the receiver and controls the access control system or gate 4 Confirm that the transmitter activate the CYCLE relay by observing that the YELLOW LED blinks once with each press of the transmitter 5 The FREE EXIT OPEN output is automatically...

Страница 4: ...ina AXURIM REV 0420 2020 GHOST CONTROLS WARNING This product can expose you to chemicals including lead which is known to the State of California to cause cancer For more information go to www P65Warnings ca gov ...