9 Specification
Display range
-1999..+9999 Digit
Accuracy
Model dependent refer to 10 Sensor accuracies on page 15
Pressure media
Suitable for air, non corrosive, non-oxidizing and non-reducing gases
Sensor
Silicon MEMS
Temperature compensation Integrated in sensor element from 0..70 °C
Measuring rate
Up to 1000 measurements per second
Adjustment
Digital offset and scale correction
Min and max value memory Memory function for min and max value
Output signals
Arbitrary scale from 0..10 V and 4..20 mA
Scaling
Via selection in settings menu setting the output value for 4 mA (or 0 V) and 20
mA (or 10 V)
Connection
Elbow-type plug according to EN 175301-803 Form A (IP65)
Max cable cross-section 1.5 mm², cable diameter 4.5..7 mm
Auxiliary energy
4..20 mA:
From 4..20 mA current loop
0..10 V: Uv = 18..30 V, max 6 mA
Permissible impedance
4..20 mA:
RA(Ohm) < ( (Uv - 12V) / 0,02 A )
Example: for Uv = 18V: RA < (18V - 12V) / 0,02A => RA < 300 Ohm
Permissible load
Switching output
0 .. 10 V: RL(Ohm) > 3000 Ohm
Max 28 V, 40 mA
Display
4-Digit 7-Segment LCD-Display, display range from -1999..+9999 Digit
Operational controls
3 Switches
Ambient conditions
Operating / Storage temp.
Relative humidity
-20..+70 °C (25 °C nominal temperature) / -40..+70 °C
0..95 % RH (non-condensing)
Housing
ABS (IP65, without sensor)
Dimension
82 x 80 x 55 mm (without connector and pressure connection)
Mounting
4.2 mm mounting-holes for wall mounting inside the housing
Directives / standards
The device classification according to CiSPR 11 (DIN EN 55011):
Class B Group 1, for using in industrial, private and residential areas.
The device confirm to following European directives:
2014/30/EU EMC directive
2011/65/EU RoHS
2014/68/EU Pressure equipment directive
According to the pressure equipment directive 2014/68/EU for
gasses of fluid group 2 the device fulfills the conformity assessment
procedure corresponding article 4, paragraph 3. According to this no
declaration in the EU conformity is needed.
Applied harmonized standards:
EN 61326-1 : 2013
EN 61326-2-3 : 2013
Emission level: Class B
EMI immunity according to table 1
Additional fault during perturbation:
Evaluation criterion A: <= ±1 %
Evaluation criterion B: <= ±1,7 %
An appropriate external surge protection (e.g. in case of direct / indirect
lightning stroke) must be installed when using cable length > 30 m, when the
cabling is leaving parts of the building or when using on a central direct current
power supply.
The cable length on the transistor output must not exceed 3 m and must not
leave parts of the building!