Operating Manual EASY

LOG

 80IMP… 

page 5 of 16 

3. Product description 

3.1  Required accessory 

The 

EASY

LOG 

80IMP…

 is configurated, started and read-out via the 

EASYBus

-interface. 

Therefore the following accessories are required:  

 

Level converter

 

- RS232 <> 

EASYBus

 

(i.e. EBW 1, EBW 64, EBW 240) 

- USB <> 

EASYBus

 

(i.e. EBW 3) 

  Connecting cable: level converter to 

EASY

LOG

 

 

GSOFT 40K

 (version >7.14): 

 

  Windows software to start the logger and read out the logger-data 

 

EASYBus-Configurator

 (version >2.0): 

  for the configuration of the extended settings 

3.2 

Notes on the logger’s delivery status 

The delivered logger is in a “sleep mode”, that means nothing is displayed and the 

power consumption is at its minimum. When there is a communication with the software 

for the first time, the EASY

LOG

 leaves the sleep mode and ›Stop‹ is displayed. Then the 

device is ready for operation. 
Note: 

That sleep mode (nothing is displayed) cannot be restored again. 

“Stop“ or  “Halt“ are similar to the sleep mode. Both of  that operation 

modes ensure minimum consumption. 

Note: 

Logger start over keypad: 

before logger start over keypad, logger time must be adjust with 

GSOFT 40K. 

3.3  Programming of the display range 

The display range, position of decimal point and the display unit can be set by the 

EASYBus-Configurator 

software.  

Furthermore, it can be used to read out sensor information (unit type, serial number, 

address, etc.) and to program the alarm points of the logger. 
 

3.4  EASYBus connector 

 

 

 
 
 
 
 
 
 
 

 

 

 

Assignment of panel jack 

(view on pins) 

 

 

 

 

 

EASYBus

 connection

 

 

 

 

 

 

 

 

 

 

 

 

 

not connected

 

 
 

 

Содержание GREISINGER EASYLOG 80IMP Series

Страница 1: ...NY Tel 49 9402 9383 0 info greisinger de www greisinger de Installation and operating manual Data logger for impulse from version 8 0 EASYLOG 80IMP Please read these instructions carefully before use...

Страница 2: ...perating possibilities at the device min max value memory 8 6 2 Operating possibilities at the device signal edge selection 8 6 3 Operating possibilities at the device logger operation 9 6 4 Operating...

Страница 3: ...for damages and consequential damages are voided with misuse disregard of this operating manual assignment of inadequately qualified technical personnel and arbitrary modifications of the product 2 2...

Страница 4: ...only be guaranteed if the device is not subjected to any other climatic conditions than those stated under Specification 5 When connecting the device to other devices e g PC the interconnection has t...

Страница 5: ...wer consumption is at its minimum When there is a communication with the software for the first time the EASYLOG leaves the sleep mode and Stop is displayed Then the device is ready for operation Note...

Страница 6: ...lay Display element for max min Logg indicates that logger is recording BAT signals weak battery see chapter 8 AL signals an alarm state at min imum one channel 4 2 Function of the buttons brief descr...

Страница 7: ...tching contact Connecting diagram Example connecting a transducer with npn output Switch ing contact transducer power supply for transducer 5 3 Connection an EASYLOG 80IMP T TTL signal input active si...

Страница 8: ...lay by pushing the button again Delete min value Push button for about 5 seconds CLr is displayed and the min values of all measuring channels are deleted 6 2 Operating possibilities at the device sig...

Страница 9: ...tart recording Push button for about 5 seconds The main display shows run The secondary display shows no To start recording select YES with the arrow keys button or and verify with Note If no key is p...

Страница 10: ...ded to change the configuration settings With that software the following adjustment are additionally possible adjustment of display range position of decimal point and the display unit adjustment of...

Страница 11: ...r status messages are dis played STOP The EASYLOG recording has been stopped The logger memory is empty Note At this state the power consumption is at its minimum HOLD The EASYLOG recording has been h...

Страница 12: ...to the manufacturer for repair 8 4 Alarm and error messages The following messages correspond to a particular measuring channel and are dis played accordingly ALARM LOW The measured value is below the...

Страница 13: ...more than 25 units is given in the software used Resolution 1 digit Accuracy 0 1 FS at nominal temperature Display two 4 digit LCD displays about 7 and 5 8 mm high Interface EASYBus Busload equals to...

Страница 14: ...s Applied harmonized standards EN 50581 2012 EN 61326 1 2013 emissions level class B emi immunity according to table 1 additional error 1 Note When connecting long leads adequate safety measures again...

Страница 15: ...figurator Problem The alarm settings cannot be changed Possible reason The logger has still saved data Remedy Stop logger as recommended by the software delete data Problem A error message is displaye...

Страница 16: ...ction diagram for a relay with self induction recuperation diode b Connection information for GR 10 GNR 10 or GNR 232 A GND to be connected to terminal 11 of the GNR NPN to be connected to terminal 10...

Отзывы: