E40.0.5X.6C-01 

Operating Manual EASY

LOG

 80IMP… 

page 14 of 16 

Alarm function 

alarm points selectable within the display range and alarm 

delay adjustable from 0 to 500 min 

Nominal temperature  

25 °C 

Operating temperature 

-25.0 … +60.0 °C 

Storage temperature 

-30.0 … +70.0 °C 

Housing 

ABS housing, transparent screen made of polyester 

  Dimensions 

48,5 × 48,5 × 35,5 mm  (L × W × D) 

without sensor cable, angle-type plug and EASYBus plug. 

  Protection rate  

IP65 (IP00 for open cable ends of connection cable) 

Electric connection 

(for input signals)

 

approx. 0.5 m connection cable. 

cable assignment: red = ; transparent = signal – 

Directives and standards

 

The instruments confirm to following European directives: 

 

2011/65/EU  RoHS  

  2014/30/EU  EMV directives 

Applied harmonized standards: 

  EN 50581 : 2012 

  EN 61326-1:2013  emissions level: class B 

   

 

 

emi immunity according to table 1  

   

 

 

additional error:  < 1% 

 

Note:   When connecting long leads adequate safety measures 

against voltage surges have to be taken.

 

10.  Decommissioning, reshipment and disposal 

 

10.1  Reshipment 

 

All devices returned to the manufacturer have to be free of any residual of 

measuring media and other hazardous substances. Measuring residuals at 

housing or probe may be a risk for persons or environment. 

 

Use an adequate transport package for reshipment, especially for fully functional 

devices. Please make sure that the device is protected in the package by 

enough packing materials. 

10.2  Disposal instructions 

 

The device must not be disposed in the unsorted municipal waste!  

Send the device directly to us (sufficiently stamped), if it should be disposed.  

We will dispose the device appropriate and environmentally sound. 

 

 

Содержание GREISINGER EASYLOG 80IMP Series

Страница 1: ...NY Tel 49 9402 9383 0 info greisinger de www greisinger de Installation and operating manual Data logger for impulse from version 8 0 EASYLOG 80IMP Please read these instructions carefully before use...

Страница 2: ...perating possibilities at the device min max value memory 8 6 2 Operating possibilities at the device signal edge selection 8 6 3 Operating possibilities at the device logger operation 9 6 4 Operating...

Страница 3: ...for damages and consequential damages are voided with misuse disregard of this operating manual assignment of inadequately qualified technical personnel and arbitrary modifications of the product 2 2...

Страница 4: ...only be guaranteed if the device is not subjected to any other climatic conditions than those stated under Specification 5 When connecting the device to other devices e g PC the interconnection has t...

Страница 5: ...wer consumption is at its minimum When there is a communication with the software for the first time the EASYLOG leaves the sleep mode and Stop is displayed Then the device is ready for operation Note...

Страница 6: ...lay Display element for max min Logg indicates that logger is recording BAT signals weak battery see chapter 8 AL signals an alarm state at min imum one channel 4 2 Function of the buttons brief descr...

Страница 7: ...tching contact Connecting diagram Example connecting a transducer with npn output Switch ing contact transducer power supply for transducer 5 3 Connection an EASYLOG 80IMP T TTL signal input active si...

Страница 8: ...lay by pushing the button again Delete min value Push button for about 5 seconds CLr is displayed and the min values of all measuring channels are deleted 6 2 Operating possibilities at the device sig...

Страница 9: ...tart recording Push button for about 5 seconds The main display shows run The secondary display shows no To start recording select YES with the arrow keys button or and verify with Note If no key is p...

Страница 10: ...ded to change the configuration settings With that software the following adjustment are additionally possible adjustment of display range position of decimal point and the display unit adjustment of...

Страница 11: ...r status messages are dis played STOP The EASYLOG recording has been stopped The logger memory is empty Note At this state the power consumption is at its minimum HOLD The EASYLOG recording has been h...

Страница 12: ...to the manufacturer for repair 8 4 Alarm and error messages The following messages correspond to a particular measuring channel and are dis played accordingly ALARM LOW The measured value is below the...

Страница 13: ...more than 25 units is given in the software used Resolution 1 digit Accuracy 0 1 FS at nominal temperature Display two 4 digit LCD displays about 7 and 5 8 mm high Interface EASYBus Busload equals to...

Страница 14: ...s Applied harmonized standards EN 50581 2012 EN 61326 1 2013 emissions level class B emi immunity according to table 1 additional error 1 Note When connecting long leads adequate safety measures again...

Страница 15: ...figurator Problem The alarm settings cannot be changed Possible reason The logger has still saved data Remedy Stop logger as recommended by the software delete data Problem A error message is displaye...

Страница 16: ...ction diagram for a relay with self induction recuperation diode b Connection information for GR 10 GNR 10 or GNR 232 A GND to be connected to terminal 11 of the GNR NPN to be connected to terminal 10...

Отзывы: