FR 30 TOUCH - RAPID 30 TOUCH_
49.0261.00
ENGLISH
PROBLEM
CAUSE
SOLUTION
By pressing the button (45)
“
” ithe display does not
turn on.
Low battery.
Main fuse blown.
The battery’s plug is still lo-
cated in the charger’s outlet.
Check that the battery is
charged.
Replace the main 5A or 80A fuse.
Place the plug correctly.
The brush does not rotate.
Function card damaged.
Display card damaged.
The touch sensor on the
handle is defective.
Brush motor damaged.
Brush button not pressed.
Replace.
Replace.
Replace.
Replace.
Press the relative button.
Aspirator does not work.
Function card damaged.
Display card damaged.
Intake motor damaged.
Aspirator button not pressed.
Recovery tank full.
Replace.
Replace.
Replace.
Press the button.
Empty, wash and clean the
tank and the probes.
The machine does not dry
well, leaving traces of water
on the floor.
Aspirator off.
Aspiration tube blocked.
Dirty wiper.
Recovery tank full.
Dirty water filter clogged.
Squeegee rubber blades
worn.
Start up the aspirator.
Check and if necessary
clean the aspiration tube that
connects the squeegee to
the recovery tank.
Clean the wiper.
Empty the recovery tank.
Clean the filter.
Replace or turn over the
squeegee rubber blades.