For safety reasons, the unit moves only while pressing a button of the
MCP. When you stop pressing, all moving-operations will stop
immediately
.
8.2.1 Shift
The top five control units (1-5) are divided into two sections (black/grey). Press
SHIFT (6) to change from the black to the grey control sections. Press SHIFT (6)
again to return to the black control sections.
8.2.2 Memory Positions
You can set four Memory Positions (M1-M4). Proceed as follows:
1.
Adjust the desired treatment position.
2.
Press SHIFT.
3.
Press SAVE (
).
4.
Press the desired Memory Position M1-M4.
To activate a saved Memory Position press SHIFT and then the relevant Memory
Position M1-M4.
8.2.3 Key lock
Locking/unlocking:
Press and hold the key-lock button and
immediately after (within 1 second) the shift button. Keep on holding
both buttons for at least 2 more seconds until you hear an acoustic
signal.
8.3. Mixing valve
PediSpa Basic only.
with backflow protection
2*connection AG 1/2" (cold/warm)
1*outflow AG 1/2"
Ceramic upper portion 1/2"
Mixing valve with ceramic disks
Inside micrometer 60 mm
cover panel 12*60 mm
Valve 1: amount of water.
Valve 2: temperature.