background image

 

 

1.1 Abbreviations 

 

Lina Select Alu  

Lina Select Wood  

Lina Select Static

 

 

Generally referred to as 

Lina 

Select

 in the instruction manual. 

 

 

Operating advice 

 

1.2 Signal words 

 

 DANGER!

 indicates a hazardous 

situation which, if ignored, will result in 

death or serious injury. 

 

WARNING!

 indicates a hazardous 

situation which, if ignored, could result 
in death or serious injury. 

 

 

 CAUTION!

 indicates a hazardous 

situation which, if not avoided, may 

result in minor or moderate injury. 

NOTICE!

 indicates possible damage to 

the treatment table / appliance. 

 

 

1.3 Safety instructions 

 

 DANGER

 

 

To reduce the risk of electrocution: 

 

1.  Non-compliance of the orders of this instruction manual will 

endanger the life and health of the operator and of the customer 
and / or can result in damage to the Lina Select. 

2.  All electrical work necessary for connection to the power supply 

must be carried out by a qualified specialist (electrical engineer).   
No modifications may be made to the power supply. 
The connection must be made in accordance with the locally 
applicable legal regulations. RISK OF ELECTRIC SHOCK!  

3.  The mains voltage and the mains frequency 

must

 correspond to 

the values indicated on the rating plate.  

4.  Do not make 

any

 changes or manipulations to the Lina Select

 

and/or its power supply (mains cable/mains plug).  
In case of unauthorized changes or manipulations, 

any

 warranty of 

the Gharieni Group GmbH is excluded. 

5. 

Do not connect

 the Lina Select to the mains if the treatment table 

itself or the power cable or the plug are visibly damaged. RISK OF 
ELECTRIC SHOCK! 

Содержание Lina Select Alu

Страница 1: ...Gharieni Group GmbH Gutenbergstra e 40 47443 Moers Germany Phone 49 0 2841 88300 0 Fax 49 0 2841 88300 999 Sales department 49 0 2841 88300 300 E mail service gharieni com Web www gharieni com Area t...

Страница 2: ...properly Read the instructions very carefully and only operate the Lina Select in the intended use as described in this instruction manual This is the only way to protect your customers and yourself...

Страница 3: ...stallation 14 7 Rating plate 15 8 QR Code 15 9 Upholstery and base versions 20 9 1 Upholstery 20 9 1 1 Standard upholstery artificial leather 20 9 1 2 Soft upholstery polyurethane 20 9 2 Base versions...

Страница 4: ...Locking function of the hand control without memory 41 11 1 3 Memory hand control Lina Select Wood Static 42 11 1 3 1 Locking function 46 11 1 3 2 Memory function of the hand control 48 11 1 3 3 Adjus...

Страница 5: ...g 85 19 1 Repair 86 20 Optionally available accessories 87 20 1 Castor set 87 20 2 XL extension 87 20 3 Neckrest Dentalax 88 20 4 Protective covers for treatment tables 88 21 Upholstery care and clean...

Страница 6: ...our clients MAKE SURE THAT THIS MANUAL IS AVAILABLE TO ANYONE USING THE GHARIENI TREATMENT TABLE LINA SELECT AND MAKE SURE THAT IT HAS BEEN READ AND UNDERSTOOD PRIOR TO USING THE TREATMENT TABLE This...

Страница 7: ...er the life and health of the operator and of the customer and or can result in damage to the Lina Select 2 All electrical work necessary for connection to the power supply must be carried out by a qu...

Страница 8: ...plug the Lina Select if it is not used for a longer period 12 Always disconnect the Lina Select from the mains before cleaning and or maintenance RIKS OF ELECTRIC SHOCK 13 Never pull the power supply...

Страница 9: ...t thoroughly RISK OF ELECTRIC SHOCK 10 Never immerse any parts of the Lina Select in water When cleaning the Lina Select make sure that no water penetrates the Lina Select or its housing RISK OF ELECT...

Страница 10: ...the cord away from heated surfaces 22 Never drop or insert any object into any opening 23 Do not use the Lina Select outdoors 24 Do not allow any unauthorized person to operate the Lina Select 25 Use...

Страница 11: ...al capabilities RISK OF INJURY CHOKING HAZARD 38 Always keep children and pets away from the Lina Select 39 Children must not play with the Lina Select or its single components 40 The Lina Select is n...

Страница 12: ...d use as described to protect you and your customers from danger The Gharieni Lina Select is no medical device The Lina Select is a treatment table It is suitable for facial treatments hair removal pe...

Страница 13: ...ee space for the Lina Select relevant to its total length In some countries the Lina Select is delivered in a cardboard depending on delivery The leg section is folded by 90 see picture below Fig simi...

Страница 14: ...ing sitting surface or its armrests during transport otherwise you can damage the Lina Select seriously On flat surfaces the Lina Select can be moved or transported carefully using the optional castor...

Страница 15: ...store them at a safe place for future use 6 3 Installation The Lina Select is easy to install and can be adapted to all human body measurements You can adjust the desired positions electrically in a v...

Страница 16: ...ave the serial number always at hand 8 QR Code In case of service you can scan the QR code using the OCR scan function of a suitable device e g a smartphone A form will then open via the Internet brow...

Страница 17: ...16 B QR CODE Figure similar position differs...

Страница 18: ...17 Figure shows form that opens in the Internet browser of the device after the QR code is scanned...

Страница 19: ...18 Figure shows form that opens in the Internet browser of the device after the QR code is scanned...

Страница 20: ...19 Figure similar option window for adding a file Appearance may vary depending on the device and operating system...

Страница 21: ...BACKREST Fig similar colour design and equipment may vary depending on model 9 1 2 Soft upholstery polyurethane The SOFT UPHOLSTERY of the Lina Select s fig below is a comfortable high quality and ext...

Страница 22: ...available in three base versions 9 2 1 Lina Select Alu The base of the Lina Select Alu consists of a solid aluminium clad foot which offers a decorative eye catcher thanks to the wood or artificial l...

Страница 23: ...and upholstery may vary depending on model 1 BASE WITH WOOD DECOR 9 2 3 Lina Select Static The base of the Lina Select Static is anchored firmly into the floor by screws This kind of installation off...

Страница 24: ...e programmed and four individually adjustable and storable memory positions Hand control Lina Select Wood and Lina Select Static has four pre programmed and two individually adjustable and storable me...

Страница 25: ...stment of the WORKING HEIGHT Actuator 1 Electrical adjustment of the BACKREST Actuator 2 Electrical adjustment of the INCLINATION OF THE SEAT AREA Actuator 3 Electrical adjustment of the LEGREST The A...

Страница 26: ...HT 3 Mechanism of the electrical adjustment of the INCLINATION OF THE SEAT AREA the seat inclination electrically adjustable for all base versions see also chapter 11 1 1 5 11 1 2 3 resp 11 1 3 5 ADJU...

Страница 27: ...versions see also chapter 11 2 4 LEGREST see also chapter 11 1 1 6 11 1 2 4 resp 11 1 3 6 ADJUSTMENT OF THE LEGREST 9 FOOTREST manually extendable removable see also chapter 11 2 4 LEGREST see also ch...

Страница 28: ...injuries It is essential that no parts of the body or items are below or between the parts of the Lina Select while adjusting the lying position RISK OF CRUSHING WARNING Ensure that no parts of the b...

Страница 29: ...r eight buttons are defined for both levels i e for level 1 as well as for level 2 functions How to save or retrieve specific lying positions is described in section LINA SELECT ALU MEMORY FUNCTION OF...

Страница 30: ...white lettering arrows Push buttons for the retrieval of the pre programmed MEMORY POSITIONS SEAT AREA and MASSAGE grey lettering s table below PRE PROGRAMMED MEMORY POSITIONS C C1 Push buttons for th...

Страница 31: ...in level 1 only 3 SAVE BUTTON level 2 button grey lettering You can set the hotkeys M 1 M 4 to any desired treatment position using the SAVE BUTTON Available in level 2 only 4 SHIFT BUTTON You can ch...

Страница 32: ...e the SHIFT BUTTON is off 2 Press and hold the LOCKING BUTTON for approx 4 seconds until an acoustic signal sounds 3 The LED above the LOCKING BUTTON goes on 4 The LOCKING FUNCTION is activated and th...

Страница 33: ...e memory positions memory function on level 2 M 1 M 2 M 3 M 4 The memory function saves your desired treatment positions Press the push buttons M 1 M 4 s fig chapter 11 1 1 ALU DESIGN HAND CONTROL OF...

Страница 34: ...ensures that your clients can sit down on the Lina Select comfortably and safely and leave it as well MEMORY POSITION MASSAGE This memory position is perfectly suitable for massages in prone position...

Страница 35: ...lect is adjustable from approx 54 cm up to approx 96 cm The horizontal WORKING HEIGHT of the Lina Select soft upholstery is adjustable from approx 59 cm up to approx 101 cm due to the thicker upholste...

Страница 36: ...gers cannot be caught between the backrest and the seat RISK OF CRUSHING 11 1 1 5 Adjustment of the inclination of the seat area The inclination of the seat area of the Lina Select can also be adjuste...

Страница 37: ...sition when the LEGREST is level with the seat s fig below Fig similar colour upholstery and design may vary depending on model 4 SEAT 8 LEGREST 11 1 1 6 1 Footrest As well as the HEADREST you can pul...

Страница 38: ...ed with danger is made consciously by this For the direction of movement please note the arrow symbols and the number of dots in the upper area of the hand control By simply pressing a button and hold...

Страница 39: ...height For adjustment of the WORKING HEIGHT press button T 1 of the hand control s fig in chapter 11 1 2 HAND CONTROL WITHOUT MEMORY LINA SELECT WOOD STATIC The direction of movement up or down is ind...

Страница 40: ...of dots on the hand control Press the button once and hold it down to raise the backrest Press the button twice and hold it down to lower the backrest WARNING While adjusting always check that finger...

Страница 41: ...button once and hold it down for an upward movement Press the button twice and hold it down for a downward movement and hold the button down each time to adjust the legrest You have reached the highes...

Страница 42: ...em itself locks automatically after 30 minutes of inactivity The current heating cycle is not affected Manual locking also does not affect the heating cycle currently running and does not affect the o...

Страница 43: ...and holding down the corresponding button Furthermore you can individually adjust and save two memory positions It is also possible to recall the four pre set positions The hand control has 12 buttons...

Страница 44: ...CLINATION OF THE SEAT AREA T 4 Button for adjustment of the LEGREST T 5 PROGRAM BUTTON P1 PROGRAM BUTTON P1 moves the Lina Select to the fixed entry position The entry position cannot be changed T 6 P...

Страница 45: ...est extended to the max The massage position cannot be changed T 9 MEMORY BUTTON M1 MEMORY BUTTON M1 moves the Lina Select to the first individually adjusted position T 10 MEMORY BUTTON M2 MEMORY BUTT...

Страница 46: ...ted with danger is made consciously by this 2 SYMBOL FOR RESET if a serious error occurs See chapter 17 RESET AND INITIALIZATION A reset procedure is only possible in the event of a system error WARNI...

Страница 47: ...ws via flashing of all LEDs of the hand control ana several beeps depending on the automatic locking time automatic locking after 30 minutes 1 beep and 1 time flashing of all LEDs of the hand control...

Страница 48: ...through flashing of all LEDs of the hand control and beeps The automatic locking time is always changed in this sequence 30 min 60 min 90 min 120 min no automatic locking Buttons T9 T 10 F3 LOCKING T...

Страница 49: ...has two individually adjustable and storable positions memory positions M 1 M 2 The memory function saves the treatment positions you have selected thus simplifying your workflows Use buttons M1 and...

Страница 50: ...e thicker upholstery The entry height is the lowest position of the seat Lina Select approx 54 cm seat in horizontal position Lina Select soft upholstery approx 59 cm seat in horizontal position Extra...

Страница 51: ...symbols and the number of dots on the hand control Press the button once for an upward movement or twice for a downward movement and hold it down each time to adjust the inclination of the seat area...

Страница 52: ...LEGREST 8 to increase its length Furthermore you can remove the FOOTREST 9 so you can work on the heel area pedicure This setting is also suitable when you want to carry out massages without using ad...

Страница 53: ...massage position extract the headrest by approx 10 cm Our popular NECKREST DENTALAX is optional available for our treatment tables The NECKREST DENTALAX supports the cervical spine effectively and wil...

Страница 54: ...11 2 3 Backrest The backrest 5 of the Lina Select is electrically adjustable s fig in chapter 10 4 VIEW and s chapter 11 1 1 4 11 1 2 2 resp 11 1 3 4 ADJUSTMENT OF THE BACKREST For lumbar support the...

Страница 55: ...ally adjustable s fig in chapter 10 4 VIEW and s chapter 11 1 1 6 11 1 2 4 resp 11 1 3 6 ADJUSTMENT OF THE LEGREST Usually the Lina Select is entered from the side Fold back the armrests for easy acce...

Страница 56: ...trol The foot control is equipped with a left and a right footswitch unit s below fig 1 which are connected by an electric connector s below fig 2 with 6 diodes on it The foot control allows the contr...

Страница 57: ...L 1 and L 2 LEFT FOOT SWITCH UNIT push buttons to adjust the selected actuator The direction of movement up or down is indicated by the arrow symbols push buttons to save and retrieve the treatment po...

Страница 58: ...is saved HOW TO RETRIEVE A PREVIOUSLY SAVED TREATMENT POSITION MEMORY POSITION You can retrieve two previously set treatment positions using the left foot switch unit 1 Press the push button R 2 of th...

Страница 59: ...stored memory positions In addition the heating system can be operated and the bed can be locked and unlocked The operation is done in the double tap system as with the hand control This is for safet...

Страница 60: ...OF THE FOOT CONTROL RIGHT PART OF THE FOOT CONTROL LEFT PART OF THE FOOT CONTROL 1 WORKING HEIGHT UP DOWN 2 BACKREST UP DOWN RIGHT PART OF THE FOOT CONTROL 3 INCLINATION OF THE SEAT AREA UP DOWN 4 LEG...

Страница 61: ...left section of the foot control press pedal 2 simultaneously and keep them pressed until the position is reached THE ENTRY POSITION CANNOT BE CHANGED Lock unlock Left section of the foot control pre...

Страница 62: ...ssociated with danger is made consciously by this By simply pressing a button and keeping it pressed a movement is made upwards Pressing a button twice double tap system and keeping it pressed makes a...

Страница 63: ...on the heating system with the first heating level to change to the next heating level or to switch off the heating system the buttons of the Bluetooth foot control must be held down for approx one s...

Страница 64: ...rt of the foot control button 2 and the right part of the foot control button 4 simultaneously twice double tap and keep them pressed until the position is reached THE MASSAGE POSITION CANNOT BE CHANG...

Страница 65: ...heating of a cold lying surface after starting the Smart Thermo will operate with max power during the pre heating period The heating programme of the Smart Thermo is fully automated and switches off...

Страница 66: ...flammatory processes and other medical conditions which make heat applications or this form of client positioning questionable must always consult a doctor before use WARNING Never use the Lina Select...

Страница 67: ...CONTROL PANEL OF THE HEATING SYSTEM SMART THERMO 3 BUTTON ON BUTTON OFF TEMPERATURE SELECTION BUTTON TIME SELECTION BUTTON LEDS A 2 blue LEDs B 2 green LEDs C 2 yellow LEDs D 2 orange LEDs E 2 red LE...

Страница 68: ...s sequence is pre programmed The heating power level and the heating time of the Smart Thermo can be changed at any time by using the corresponding buttons s description below TEMPERATURE SELECTION BU...

Страница 69: ...e button once more six times the selection cycle will begin at level 1 again TIME SELECTION BUTTON Press this button to set the required heating time of the Smart Thermo Ten time settings in 10 minute...

Страница 70: ...es 7 Now the appliance heats for 30 minutes at the selected heating power level 8 After the set time has elapsed the Smart Thermo switches off automatically If you wish to quit the heating time earlie...

Страница 71: ...fully automated and switches off automatically after a total time of 90 minutes s chapter 15 1 OPERATION Various automatic locking times can be set s chapter 11 1 3 1 LOCKING FUNCTION The currently ru...

Страница 72: ...Wood Static from the power supply if it will not be used for an extended period e g over night WARNING People with acute pain venous disorders low blood pressure inflammatory processes and other medic...

Страница 73: ...ting system The heating system comes with three heat power levels To quickly heat up the bed s surface before starting treatment we recommend setting the heating system to level 2 only in exceptional...

Страница 74: ...level 2 double impulse lights up for 0 3 seconds interval 1 second 60 button Push this button again level 3 triple impulse lights up for 0 3 seconds interval 1 second 90 button Push this button again...

Страница 75: ...90 Pedals buttons 2 4 Push these pedals buttons again Power off NOTICE For operation of the heating system using the Bluetooth foot control s chapter 13 1 NOTICE If the heating system is not present...

Страница 76: ...he housing of the hand control Non compliance will expire the warranty WARNING Liquids must not get into the hand control RISK OF ELECTRIC SHOCK WARNING Persons with a pacemaker must not operate or us...

Страница 77: ...NESS MASSAGE BUTTON WAVE BUTTON 5 INTENSITY BUTTONS SHOULDER AREA BACK AREA 6 INTENSITY BUTTONS FUSELAGE AREA BACK AREA 7 INTENSITY BUTTONS PELVIC AREA BACK AREA 8 INTENSITY BUTTONS LEG AREA 9 INTENSI...

Страница 78: ...the first time the manufacturer s setting is activated intensity level 2 medium intensity When an individual setting has been set before s below INDIVIDUAL SETTING the previously set setting is start...

Страница 79: ...ividual settings are saved after the massage PULSE MASSAGE 3 Press the PULSE MASSAGE BUTTON 3 to start the massage with the first of the three programmes Press the PULSE MASSAGE BUTTON 3 a second time...

Страница 80: ...BUTTONS 5 9 Please note The WELLNESS MASSAGE will be restarted in the manufacturer s setting HOW TO FINISH A MASSAGE A timer finishes a massage after 15 minutes automatically If you want to stop the m...

Страница 81: ...ly saved memory values are deleted except pre programmed memory positions 17 2 Initialization If a previously saved position is no longer properly set you may have to initialise the software of the Li...

Страница 82: ...ositions are reached INITIALISATION LINA SELECT WOOD STATIC 1 The BACKREST ACTUATOR must be fully extended The BACKREST must have an angle of approx 75 to the seat area use button T 2 of the hand cont...

Страница 83: ...manually i e each actuator must be run individually Please note that you keep the buttons pressed for 2 3 seconds longer after reaching the end position WARNING The adjustment initialisation must be...

Страница 84: ...bracelets while carrying out any cleaning or maintenance operations Otherwise you can scratch and damage the upholstery and or the material of the base of the Lina Select unintentionally Use water or...

Страница 85: ...on a cloth 18 1 2 Cleaning and care of the polyurethane material PU Clean the PU material using a soft cloth only provided with a small amount of a suitable cleaning agent also available from Gharien...

Страница 86: ...replaced please contact the customer service SINGLE ACTUATOR DOES NOT WORK 1 Actuator plug is not connected properly 1 Connect plug properly 2 Hand control is defective 2 Hand control must be replace...

Страница 87: ...r daily use 5 Check the power cord regularly for signs of damage 6 If the mains cable is damaged it may only be replaced by Gharieni Group GmbH or a customer service authorized by Gharieni Group GmbH...

Страница 88: ...SET with brakes Article number 73006 20 2 XL extension An XL EXTENSION for the treatment table of the Lina Select line is optionally available for an additional charge The attachment serves for extens...

Страница 89: ...Fig similar colour and design may vary depending on the model selected NECK REST DENTALAX Article number 46005 For detailed information regarding the suitable version for your treatment table please...

Страница 90: ...when purchasing the treatment table COSMETIC VERSION PODO VERSION Fig similar fig serves as an example only For detailed information regarding the right size and suitable version of the covers as well...

Страница 91: ...ive for gentle and thorough care and cleaning of the upholstery Mikrozid Sensitive removes bacteria fungi and viruses e g HBV Rota Vaccinia etc Mikrozid Sensitive is available as liquid Suitable for c...

Страница 92: ...91 For more information visit the manufacturer s website at the following link https www schuelke com intl en products mikrozid sensitive liquid php...

Страница 93: ...thorough care and cleaning of the artificial leather upholstery we additionally recommend Skai cleaner Skai cleaner is available in a 200 ml spray bottle Especially suitable for cleaning artificial le...

Страница 94: ...ents incl adjustable feet approx 54 cm 96 cm Range of height adjustments incl adjustable feet soft upholstery approx 59 cm 101 cm Range of height adjustments incl castors approx 8 00 cm optional acces...

Страница 95: ...HEATING SYSTEM SMART THERMO 3 LINA SELECT ALU OPTIONAL EQUIPMENT Power supply 230 V AC 48 60 Hz Power consumption ca 120 W max Protection 630 mA T Transformer output voltage 12 V AC ca 9A max Technica...

Страница 96: ...the entire power cord Dispose of the power cord and the plug immediately 6 The Lina Select is made of metal and plastic components electronic components electric cables Dispose of the separate compone...

Страница 97: ...l types of lamps as well as glass panels consumables such as terry products etc are not covered by this guarantee Furthermore no warranty claims will be granted if the treatment table and its componen...

Страница 98: ...mber PediSpa series MLR Wet MLW Space MLX iDome MLX i3 Cube Dome MLR MLX RLL series Ellipse 601 E Line 601 Podo 2022 Relevant EU directives and harmonized standards used 2006 42 EU Machinery Directive...

Страница 99: ...Seventh edition 8 64 70 94 05 10 2022 NOTES THE PROPERTY RIGHTS OF THIS INSTRUCTION MANUAL ARE RESERVED ITS REPRODUCTION OR TRANSMISSION TO THIRD PARTIES IS FORBIDDEN WITHOUT THE AUTHORISATION OF THE...

Отзывы: