GGM GUF Series Скачать руководство пользователя страница 1

www.ggm.co.kr

GUF

 

SERIES

BLDC SPEED CONTROL UNIT

GLOBAL GEARED MOTOR

OPERATION MANUAL

Headquarters / 1st Factory : 22, Gyeongin-ro 3beon-gil, Bucheon-si, Gyeonggi-do, Republic of Korea
Tel:+82-32-664-7790   Fax:+82-32-611-7791

  Attached research institute / No. 2 factory : 180, Oksan-ro, Bucheon-si, Gyeonggi-do, Republic of Korea

Tel:+82-32-684-7791    Fax:+82-32-683-5059

Содержание GUF Series

Страница 1: ...TION MANUAL Headquarters 1st Factory 22 Gyeongin ro 3beon gil Bucheon si Gyeonggi do Republic of Korea Tel 82 32 664 7790 Fax 82 32 611 7791 Attached research institute No 2 factory 180 Oksan ro Buche...

Страница 2: ...t is being applied Be sure to only perform repair or installationwork after cutting off the power supply Failure to do so may cause an electric shock Have a qualified person with relevant knowledge in...

Страница 3: ...0V three phase 200 240V Permissible range 10 50 60 Hz Permissible range 5 Rated Output Current Rated Torque Maximum Instantaneous Torque Rated Speed Speed Control Range Speed Regulation Power input Te...

Страница 4: ...240V Three phase 200 240V F Series Unit Type GGM Co LTD 4 58 90 4 111 116 STAND BY RUN FWD REV GGM GGM CN3 SENSOR CN2 MOTOR CN4 I O CN1 200 240V 80 52 2 4 5 HOLE 98 2 4 5 THRU 2 M3 DP8 64 5 104 5 124...

Страница 5: ...l buttons 5 Operation by external I O PLC etc Start Stop change of rotational direction multi level speed operation by external I O etc 6 Display indication load ratio actual speed etc Display of load...

Страница 6: ...r turning on the alrarm code AL oP Pervention of operation at power on alarm is displayed and the do not operated motor Set the operation switch from RUN to STAND BY for release an alarm before use mo...

Страница 7: ...Lock When pressing the S button the rotation speed is determined When the display is blinking the rotation speed has not set Can lock the operation by pressing the S button for more than 5 seconds in...

Страница 8: ...P0 operation data 1 P1 operation data 2 P2 operation data 2 A rst Alarm reset E Err External alarm Output signals Can be used 3 functions out of SPd Speed output AL on Alarm output AL ov Overvoltage a...

Страница 9: ...sistor output type programmable controller Attention For the Y0 Y1 and Y2 be sure to keep the current value at 100mA or less If the current exceeds this value connect the limiting resistor R 1 Limited...

Страница 10: ...side 2 Select the operation data number suing the P0 P1 and P2 inputs 3 When the FWD or REV input is turned ON the motor will rotate 4 Switch the operation data number using the P0 P1 and P2 inputs 5...

Страница 11: ...11 10 Setting and 7 segments display 10 1 Monitor mode...

Страница 12: ...12 10 2 Input Output setting mode...

Страница 13: ...10 3 Parameter setting mode 1page 13...

Страница 14: ...10 3 Parameter setting mode 2page 14...

Страница 15: ...10 3 Parameter setting mode 3page 15...

Страница 16: ...10 3 Parameter setting mode 4page 16...

Страница 17: ...or is calculated and input the conveyor speed can also be displayed When increasing the motor rotation speed using the external input the converted speed can be displayed After the power is turning on...

Страница 18: ...on alarm External I O function External input function X0inputfunctionselection X1inputfunctionselection X2inputfunctionselection X3inputfunctionselection X4inputfunctionselection Externaloutputfuncti...

Страница 19: ...gnable alternative input functions Description For every rotation of the motor 30 pulses are output SPEED RPM SPEED OUT Hz 60 Sec 30 pulses It is output when an alarm is generated Normally closed It i...

Страница 20: ...T ERROR Stop input Check the power supply voltage If this alarm occurs during operation reduce the load or make the acceleration deceleration time longer Review the ambient temperature Check the wirin...