10.1
Calibration procedure
The column may be calibrated in cable or wireless mode
10.1.1 Calibrating the column in cable mode
Proceed as follows
Attention:
During calibration the column must not be loaded. Calibrate only when there is
not equipment mounted on the column!
Attention:
During calibration the columns lift range will be driven through and set. The
column will drive slowly to the bottom position and then to the top position and
finally return to the starting position.
Before starting, ensure that the column’s
lift rage is in no way obstructed!
Connect the HCU and electronic unit with the delivered HCU cable by inserting the
connectors on the HCU cable into the connectors on the HCU and electronic unit
Tip:
As a reference use the alignmen
t markings on the „Fischer“
Connectors to insert correctly
Cable connection
Cable connection Dolly -
HCU
Marking Fischer
Plug
Содержание GF-Primo Dolly
Страница 18: ...17 GF Primo s 3 steering modes and selector position...
Страница 20: ...19 GF Secondo s three steering modes and their selector positions...
Страница 27: ...26 Handle Rosette Battery cover Exchangeable HCU cover HCU battery Battery cover lock...
Страница 34: ...33 Key combination to change the channel Change the channel...
Страница 37: ...36...
Страница 42: ...41 Tastenkombination zum Kalibrieren des Dolly...
Страница 60: ...59 MARKERs 3 to 6 can be selected in the same manner Setting MARKERs...
Страница 68: ...67 Recording a sequence...
Страница 70: ...69...
Страница 88: ...87...