10 Calibrating the column
When and why the column may require calibration
The column will need to be calibrated:
o
After a service or repair
o
After a software update
o
After the column is crashed / driven against an object / hit the mechanical top or
bottom of column lift range
o
After using emergency switch
Why the column must be calibrated:
After one of the above mentioned cases the column must be calibrated to ensure a perfect
column movement within the set travel range.
Attention:
If the column is not calibrated, it is possible that it may drive to the top or
bottom limits and in turn damage mounted equipment.
Tip:
When operating the column observe the digital display, indicating the
movement of the column. Before the take, firstly, drive through the lift range of
the move at a slow speed first.