GFA 10004000 10011 Скачать руководство пользователя страница 19

 

  

19 

 

11

 

Declaration of incorporation / Declaration of conformity 

Declaration of incorporation  

within the meaning of Machinery Directive 2006/42/EC 
for partly completed machinery, Appendix II Part B 
 

Declaration of conformity 

within the meaning of EMC Directive 2014/30/EU 
within the meaning of RoHS Directive 2011/65/EU 

We,  
GfA ELEKTROMATEN GmbH & Co. KG 
declare under our sole responsibility that the 
following product complies with the above 
directives and is only intended for installation in a 
door system. 
 
Drive unit 

SIK 25.10 WS-30,00 

Part no.: 10004000 10011 
 
 
We undertake to transmit in response to a 
reasoned request by the appropriate regulatory 
authorities the special documents on the partly 
completed machinery. 
 
This product must only be put into operation 
when it has been determined that the complete 
machine/system in which it has been installed 
complies with the provisions of the above-
mentioned directives. 
 
Authorised representative to compile the 
technical documents is the undersigned. 
 
Düsseldorf, 10.08.2018 
 
Stephan Kleine 
CEO 
 

 

Signature 
 
 

  The following requirements from Appendix I of 

the Machinery Directive 2006/42/EC are met: 
1.1.2, 1.1.3, 1.1.5, 1.2.2, 1.2.3, 1.2.6, 1.3.2, 
1.3.3, 1.3.9, 1.5.1, 1.5.2, 1.5.4, 1.5.6, 1.5.7, 
1.5.8, 1.5.9, 1.5.10, 1.5.11, 1.5.13, 1.6.1, 1.6.2, 
1.6.4, 1.7.2, 1.7.3, 1.7.4.3. 
 
Standards applied: 
EN 12453:2001 
Industrial, commercial and garage doors and 
gates - Safety in use of power operated doors - 
Requirements 
 
EN 12604:2017 
Industrial, commercial and garage doors and 
gates - Mechanical aspects - Requirements 
 
EN 60335-1:2012 
Household and similar electrical appliances - 
Safety - Part 1: General requirements 
 
EN 61000-6-2:2005 
Electromagnetic compatibility (EMC) Part 6-2 
Generic standards – Immunity standard for 
industrial environments 
 
EN 61000-6-3:2007 
Electromagnetic compatibility (EMC) Part 6-3 
Generic standards – Emission standard for 
residential, commercial and light-industrial 
environments 

 

 

 

  
 

Содержание 10004000 10011

Страница 1: ...f Installation Instructions ELEKTROMAT SIK 25 10 WS 30 00 Model 10004000 10011 en Status 26 03 2021...

Страница 2: ...2 GfA ELEKTROMATEN GmbH Co KG Wiesenstra e 81 D 40549 D sseldorf www gfa elektromaten de info gfa elektromaten de...

Страница 3: ...switch connection 14 9 Emergency manual operation emergency hand crank 15 10 Completion of commissioning testing 17 11 Declaration of incorporation Declaration of conformity 19 Symbols Warning Potenti...

Страница 4: ...ng of door systems Expert knowledge relevant skills and practical experience are what set apart qualified persons They are capable of safely carrying out the tasks involving installation maintenance a...

Страница 5: ...third parties Warning Danger from improper use of the product Do not let children operate the product unsupervised or use as a toy Warning Danger to life from incorrect installation Work carried out i...

Страница 6: ...g current 4 00 A Operating frequency 50 Hz Power factor cos 0 99 Operating capacitor 35 F Maximum movement per hour 16 h 1 Hand forces 75 N Class of protection IP 54 Limit switch range maximum revolut...

Страница 7: ...cking torque and the approval number of the safety brake are available in the technical data of these instructions Warning Danger of the door dropping If you need to apply more than the permissible fo...

Страница 8: ...maximum holding torques or locking torques refer to technical data Connection elements Self locking connection elements with a minimum strength of 800 N mm2 8 8 must be used Utilize the hole diameter...

Страница 9: ...9 Mounting Two elongated holes are provided for mounting BAGAD05001_Z001...

Страница 10: ...ons of the door manufacturer must also be observed during installation Warning Potential injury or danger to life During installation be sure to use a lifting device that has a sufficient load carryin...

Страница 11: ...tach the drive unit BAGAE05003_Z001 Tighten all connection elements M12 to 75 Nm Install all other connection elements according to the specifications of the door manufacturer BAGAE05004_Z001 75 Nm 8...

Страница 12: ...energised Observe the applicable regulations and standards Make a proper electrical connection Use suitable tools Performing electrical installation Remove the cover Insert the motor plug Insert the...

Страница 13: ...13 6 Limit switch adjustment The adjustment of the final limit positions OPEN and CLOSE is described in the instructions for the door control panel...

Страница 14: ...ting capacitor M1 Motor X13 Motor plug 8 Limit switch connection F10 Thermal contact S10 Emergency manual operation X12 DES connection 1 Safety circuit 2 Channel B RS485 3 Ground 4 Channel A RS485 5 S...

Страница 15: ...the emergency manual operation must be carried out against the closed brake Warning Danger of the door dropping If you need to apply more than the permissible force of 390N according to DIN EN 12604 D...

Страница 16: ...and crank be used A wrong crank will drop out of the mounting and injure people Only use a crank with the correct diameter The diameter is indicated on the crank handle switch 1 2 m m 1 0 m m BAUA0001...

Страница 17: ...g The gearbox stalls Releasing the stalling may cause the door to drop Block the door for pedestrians and vehicles Do not release the stalling Do not use the emergency manual operation Secure the door...

Страница 18: ...al limit positions Limit switches Check the final limit positions by opening and closing the door completely The safety zone must not be reached Entire drive unit Note Have the drive checked annually...

Страница 19: ...d complies with the provisions of the above mentioned directives Authorised representative to compile the technical documents is the undersigned D sseldorf 10 08 2018 Stephan Kleine CEO Signature The...

Страница 20: ...20...

Отзывы: