background image

 

 

 

 

 

Installation Instructions

 

ELEKTROMAT 
SI 25.15-30,00

 

Model: 10003166 10011

 

 

 
 
 
 
 
 
 
 
 

 

-en- 

 

Status: 26.03.2021

 

 

 

Содержание 10003166 10011

Страница 1: ...f Installation Instructions ELEKTROMAT SI 25 15 30 00 Model 10003166 10011 en Status 26 03 2021...

Страница 2: ...2 GfA ELEKTROMATEN GmbH Co KG Wiesenstra e 81 D 40549 D sseldorf www gfa elektromaten de info gfa elektromaten de...

Страница 3: ...tion 14 9 Limit switch connection 15 10 Emergency manual operation emergency hand crank 16 11 Completion of commissioning testing 18 12 Declaration of incorporation Declaration of conformity 20 Symbol...

Страница 4: ...ng of door systems Expert knowledge relevant skills and practical experience are what set apart qualified persons They are capable of safely carrying out the tasks involving installation maintenance a...

Страница 5: ...third parties Warning Danger from improper use of the product Do not let children operate the product unsupervised or use as a toy Warning Danger to life from incorrect installation Work carried out i...

Страница 6: ...open close for frequency inverter operation 26 15 rpm Supply voltage 3N 400 V Operating current 2 30 A Operating frequency 50 Hz Power factor cos 0 53 Maximum movement per hour 20 h 1 Hand forces 118...

Страница 7: ...cking torque and the approval number of the safety brake are available in the technical data of these instructions Warning Danger of the door dropping If you need to apply more than the permissible fo...

Страница 8: ...maximum holding torques or locking torques refer to technical data Connection elements Self locking connection elements with a minimum strength of 800 N mm2 8 8 must be used Utilize the hole diameter...

Страница 9: ...longated holes are provided for mounting Use at least 2 of these for mounting Always use elongated hole A key is used to connect to the door shaft Use a key that is at least as long as the hollow shaf...

Страница 10: ...acturer must also be observed during installation Warning Potential injury or danger to life During installation be sure to use a lifting device that has a sufficient load carrying capacity Thoroughly...

Страница 11: ...AE02007_Z002 Tighten all connection elements M12 to 75 Nm Install all other connection elements according to the specifications of the door manufacturer BAGAE02011_Z003 8 8 8 8 75 Nm Secure the keys v...

Страница 12: ...energised Observe the applicable regulations and standards Make a proper electrical connection Use suitable tools Performing electrical installation Remove the cover Insert the motor plug Insert the...

Страница 13: ...13 6 Limit switch adjustment The adjustment of the final limit positions OPEN and CLOSE is described in the instructions for the door control panel...

Страница 14: ...14 7 Motor connection M1 Motor X13 Motor plug 8 Alternative motor connection M1 Motor X13 Motor plug...

Страница 15: ...15 9 Limit switch connection F10 Thermal contact S10 Emergency manual operation X12 DES connection 1 Safety circuit 2 Channel B RS485 3 Ground 4 Channel A RS485 5 Safety circuit 6 Supply voltage...

Страница 16: ...the emergency manual operation must be carried out against the closed brake Warning Danger of the door dropping If you need to apply more than the permissible force of 390N according to DIN EN 12604...

Страница 17: ...and crank be used A wrong crank will drop out of the mounting and injure people Only use a crank with the correct diameter The diameter is indicated on the crank handle switch 1 2 m m 1 0 m m BAUA0001...

Страница 18: ...g The gearbox stalls Releasing the stalling may cause the door to drop Block the door for pedestrians and vehicles Do not release the stalling Do not use the emergency manual operation Secure the door...

Страница 19: ...al limit positions Limit switches Check the final limit positions by opening and closing the door completely The safety zone must not be reached Entire drive unit Note Have the drive checked annually...

Страница 20: ...complies with the provisions of the above mentioned directives Authorised representative to compile the technical documents is the undersigned D sseldorf 10 08 2018 Stephan Kleine CEO Signature The fo...

Отзывы: