Safety Instructions
1. Prior to installation or removal:
• Depressurize and vent system
• Drain below sensor level
2. Con
fi
rm chemical compatibility before use.
3. Do not exceed maximum temperature/pressure speci
fi
cations.
4. Wear safety goggles or faceshield during installation/service.
5. Do not alter product construction.
6. Dispose of properly; DO NOT INCINERATE!
Signet 2450 Pressure Sensor
1. Description
2. Specifi cations
General
Compatibility:
2450 Digital (S
3
L) output models:
8250,
8450,
8900
2450 Current output models: PLC
Wetted materials:
• Sensor housing:
PVDF
• Diaphragm:
Ceramic
• Seal:
FPM
Process connection:
• -1X, -5X:
3
/
4
in. NPT male thread, where X = L, H
• -3X, -7X:
1
/
2
in. Union male thread,
where X = U, L, or H
Rear connection:
3
/
4
in. NPT male thread
Cable type:
3 cond + shield, 22 AWG
Standard cable length:
• 2450-1x, -3x, 5x, 7x:
4.6 m (15 ft)
Sensor Accuracy:
±1% of full scale @ 25 °C
Thermal sensitivity shift: ±0.03% of full scale per °C
Shipping weight:
• 2450-1x, 2450-3x
0.3 kg (0.65 lb)
Electrical
Power Requirements:
• Digital (S
3
L) models:
5 to 6.5 VDC ±10%, <1.5 mA
• 4 to 20 mA models:
12 to 24 VDC ±10% regulated
Short circuit & reverse polarity protected
Digital (S
3
L) output:
• Type:
Serial ASCII, TTL level 9600 bps
• Accuracy:
±1% of full scale @ 25 °C
• Repeatability:
±0.5% of full scale
• Resolution:
0.01 psi (0.001 psi for -XU)
• Update rate:
<100 ms
4 to 20 mA output:
• Accuracy:
±32
μ
A
• Repeatability:
±0.5% of full scale
• Resolution:
<5
μ
A
• Span:
Field-scaleable
(see section 6.3 for factory settings)
• Max loop impedance:
100
@ 12 V
325
@ 18 V
600
@ 24 V
• Update rate:
<100 ms
Table of Contents
1. Description
2. Speci
fi
cations
3. Installation
4. (S
3
L) wiring
5. 4 to 20 mA wiring
6. 4 to 20 mA span
adjustment
7. Ordering information
The 2450 Pressure Sensor has a one-piece injection molded PVDF body and ceramic diaphragm for superior compatibility in corrosive
liquids. These sensors are available with Digital (S
3
L) digital output or
fi
eld-scaleable 4 to 20 mA output. Select from three (3) pressure
ranges for optimal measurement resolution. Built-in temperature compensation provides outstanding accuracy over a wide operating
range. Versions with
1
/
2
in. union process connection are best suited for in-line installations.
Integral adapters (sold separately) may be used to create a compact assembly with
fi
eld mount versions of the 8250 Level Transmitter
and the 8450 Pressure Transmitter.
3-2450.090-1 Rev. H 2/11
English
*3-2450.090-1*
English
• Operating range (Max. pressure for accuracy speci
fi
cations):
-XU 0 to 0.7 bar (0 to 10 psig)
-XL 0 to 3.4 bar (0 to 50 psig
-XH 0 to 17.2 bar (0 to 250 psig)
• Vacuum range:
-XU -0.1 to 0.7 (-1.5 to 10 psi)
-XL -0.41 to 3.4 bar (-6 to 50 psi)
-XH -0.96 to 17.2 bar (-14.6 to 250 psi)
• Proof pressure (Max. pressure without damage):
-XU 1.4 bar (20 psig)
-XL 5.2 bar (75 psig)
-XH 20.7 bar (300 psig)
Environmental
• Relative humidity:
0 to 95% (Non-condensing)
• Storage temperature:
-20 °C to 100 °C (-4 °F to 212 °F)
• Operating temperature: -15 ºC to 85 °C (5 °F to 185 °F)
Standards and Approvals
• CE
• Manufactured under ISO 9001 and ISO 14001
-XU
Application Limits
Temperature
Pressure [psi]
Pressure [bar]
Dimensions
3-2450-1X, -5X
34 mm
(1.34 in.)
¾ in. NPT
¾ in. NPT
81 mm
(3.18 in.)
3-2450-3X, -7X
34 mm
(1.34 in.)
¾ in. NPT
81 mm
(3.18 in.)
½ in.
Male
Union
USE THE ATTACHED ADHESIVE LABEL TO PRESERVE THE SAFETY INSTRUCTIONS!