Fault
Possible cause
Troubleshooting
Loud noise
Valve oversized. Thus, the
valve only opens a
minimum, leading to
vibrations
Check valve dimensioning
(k
vs
value)
Valve undersized. This
results in excessive flow
velocities inside the valve
Check valve dimensioning
(k
vs
value)
Manometer does not
indicate anything
Manometer defective
Replace manometer
Buffer medium escaped
from the manometer
adaptor
Check manometer adaptor
and replace, if necessary
Manometer stays on a
constant value
Manometer defective
Replace manometer
Drill holes in the cartridge
clogged
Clean cartridge
Bonnet assembly (top
part) cannot be screwed
onto the base part
Spring not relieved
Spring cap is not in the
end stop, see Fig. 18
Screw spring cap into the
end position, see Fig. 19